Page 59

Chapter 3: Site Preparation

3-17

Display Clearance If the 7870 Scanner/Scale has an integrated display, there must be adequate clearance for viewing by the customer. In the U.S. , this is a Weights and Measurements requirement. International countries should check with their appropriate local or government agency. If the checkstand design restricts viewing, the NCR 7825 Remote Display may be used to meet visibility requirements.

60

50 30

This area must be clear for viewing integrated display.

60

R0118

Item Diverter Item Diverter (Must be removable to service Scanner/Scale in Checkstand)

7.25 in. (18.4 cm)

R0131

Page 60

3-18

Chapter 3: Site Preparation

Checkstand Hole When cutting the checkstand hole, also called a cutout, take care to maintain the specified dimensions. While this is essential for all models, it is critical for units with a scale. •

For all models, the leading edge of the Top Plate must be flush or no more than 15 cm (0.06 in.) below the top of the checkstand. The trailing edge of the Top Plate must be flush with the top of the checkstand.

•

For proper scale operation, the clearance between leading and trailing edges of the Top Plate and the checkstand must be maintained.

•

For European installations, a 5.1 cm (2 in.) border must be provided around the leading edge, trailing edge, and operator side of the scanner scale. This border must contain the words “NO WEIGH AREA.”

99999

An NCR 7870-1000 may be placed in an existing cutout for an NCR 7820 and an NCR 7870-2000 may go into a cutout for the NCR 7824. Before utilizing an existing cutout, you MUST ensure that the cutout has the correct dimensions before installing the 7870.

Page 61

Chapter 3: Site Preparation

Checkstand Hole - Models 1000 & 2000

B

C

E C

D

A

Note: Spacers are to position scale in hole. They should be below the Checkstand top.

H

D

D

C

C

G

F

E B

F A

Recommended shelf to catch NCR 7870 if dropped during installation. The 7870 must not be supported by this shelf.

No electronics under NCR 7870

NCR 7870-1000 Scanner A 29.51 cm

B 50.95 cm

C 3.49 cm

D 0.95 cm

E 43.97 cm

F 3.49 cm

G 13.0 cm

H 15.88 cm

11 5/8 in. 20 1/16 in. 1 3/8 in.

3/8 in.

17 5/16 in.

1 3/8 in.

5 1/8 in.

6 1/4 in.

NCR 7870-2000 Scanner/Scale A 30.48 cm

B 50.95 cm

C 3.49 cm

D 1.27 cm

E 43.97 cm

F 3.49 cm

G 13.0 cm

H 15.88 cm

12 in.

20 1/16 in. 1 3/8 in.

1/2 in.

17 5/16 in. 1 3/8 in.

5 1/8 in.

6 1/4 in. R0119

3-19

Page 62

3-20

Chapter 3: Site Preparation

Checkstand Hole - Models 3000, 4000, & 4500

B

C

A

Note: Spacers are to position scale in hole. They should be below the Checkstand top.

D

E C

A

B

No electronics under the 7870 NCR 7870 - 3000 Scanner A

B

C

D

E

29.51 cm

34.50 cm

0.95 cm

15.88 cm

12.54 cm

11 5/8 in.

13 5/8 in.

3/8 in.

6 1/4 in.

4 15/16 in.

NCR 7870 - 4000 & 4500 Scanner/Scale A

B

C

D

E

29.51 30.48 cm

43.97 cm

1.27 cm

15.88 cm

12.54 cm

12 .00 in.

17 3/8 in.

1/2 in.

6 1/4 in.

4 15/16 in.

Note: The 7870-3000, 4000, and 4500 must sit on a shelf below the checkstand surface. It cannot be suspended like the other units. Also, the shelf should be open at the front and back.

16631

Page 63

Chapter 3: Site Preparation

3-21

Cable Lengths and Hole Sizes When selecting a cable, take care to choose one with enough length for easy routing to the NCR 7870. Also, include enough slack to allow the unit to be lifted from the cutout without disconnecting the cables. This will be beneficial while servicing the unit. Minimum hole size data is provided for making openings to pass cables through the checkstand. Ensure after drilling that there are no sharp edges which may damage the cable. The following charts provide cable length and hole size data for AC Power Cords, DC Power Cables, Interface Cables, and Remote Display Cables. The NCR 7870 can connect to any NCR Retail Terminal as well as many competitive host terminals so a comprehensive list of interface cables has been provided.

Cable Hole Diameters Cable

Minimum Hole Size

Power Cord – Outlet to Power Supply

3.18 cm (1.25 in.)

Power Cable – Power Supply to 7870

1.52 cm (0.60 in.)

Interface Cable

1.90 cm (0.75 in.)

Remote Display Cable

1.90 cm (0.75 in.)

DC Power Cable – Power Supply to 7870 Minimum Hole Diameter: 1.52 cm (0.60 in.) Cable

Cable Length

DC Power Cable

1.22 Meters (4 Feet)

Note: DC Power Cable length is not a factor if the Power Supply is mounted on the chassis of the 7870 (Models 1000 and 2000 only).

Page 64

3-22

Chapter 3: Site Preparation

AC Power Cords – Outlet to Power Supply Minimum Hole Diameter: 3.18 cm (1.25 in.) Cable

Cable Length

US Standard

3.05 Meters (10 Feet)

US Twist-Lock

3.05 Meters (10 Feet)

International Pig-Tail

3.05 Meters (10 Feet)

Japan Standard

3.05 Meters (10 Feet)

Japan Twist-Lock

3.05 Meters (10 Feet)

Australia

3.05 Meters (10 Feet)

UK, Argentina

3.05 Meters (10 Feet)

Swiss

3.05 Meters (10 Feet)

Remote Display Cables Minimum Hole Diameter: 1.90 cm (0.75 in.) Display

Cable Corporate ID

Cable Length

7825

1416-C022-0040

4 m (13.1 ft.)

1416-C022-0080

8 m (26.2 ft.)

1416-C068-0040

4 m (13.1 ft.)

1416-C068-0080

8 m (26.2 ft.)

2552, 2557

Page 65

Chapter 3: Site Preparation

3-23

Interface Cables - NCR Host Terminals Minimum Hole Diameter: 1.90 cm (0.75 in.) Host Terminal

Interface

Cable

Corporate ID

Part Number

Length

1255

OCIA

Dual-Cable Scanner

1416-C026-0040

497-0300521

4 m (13.1 ft.)

Dual-Cable Scanner

1416-C026-0080

497-0300522

8 m (26.2 ft.)

Dual Cable Scale

1416-C027-0040

497-0300533

4 m (13.1 ft.)

Dual Cable Scale

1416-C027-0080

497-0300534

8 m (26.2 ft.) 5 m (16.4 ft.)

2113

OCIA

Scanner Only

1416-C230-0050

497-0302099

2123

OCIA

Dual-Cable Scanner

2123-K315

230-0113973

Dual-Cable Scale

2123-K315

230-0113973

Dual-Cable Scanner

1416-C014-0040

497-0300361

4 m (13.1 ft.)

Dual-Cable Scanner

1416-C014-0080

497-0300362

8 m (26.2 ft.)

Dual-Cable Scale

1416-C015-0040

497-0300371

4 m (13.1 ft.)

Dual-Cable Scale

1416-C015-0080

497-0300372

8 m (26.2 ft.)

Single-Cable

1416-C016-0040

497-0300310

4 m (13.1 ft.)

Single-Cable

1416-C016-0080

497-0300311

8 m (26.2 ft.)

2126

2127

OCIA

OCIA

2151, 2152

OCIA

Scanner Only

1416-C234-0040

497-0402970

4 m (13.1 ft.)

2154, 2155

OCIA

Single-Cable

1416-C012-0040

497-0300340

4 m (13.1 ft.)

Single-Cable

1416-C012-0080

497-0300341

8 m (26.2 ft.)

Dual-Cable Scanner

1416-C012-0040

497-0300340

4 m (13.1 ft.)

Dual-Cable Scanner

1416-C012-0080

497-0300341

8 m (26.2 ft.)

Dual-Cable Scale

1416-C013-0040

497-0300350

4 m (13.1 ft.)

Dual-Cable Scale

1416-C013-0080

497-0300351

8 m (26.2 ft.)

2156, 2157

Page 66

3-24

Chapter 3: Site Preparation

Interface Cables – NCR Host Terminals (cont.) Host Terminal

Interface

Cable

Corporate ID

Part Number

Length

2170

RS-232

Scanner Only

1416-C069-0040

497-0301380

4 m (13.1 ft.)

Scanner Only

1416-C069-0080

497-0301381

8 m (26.2 ft.)

Dual-Cable Scanner

1416-C069-0040

497-0301380

4 m (13.1 ft.)

Dual-Cable Scanner

1416-C069-0080

497-0301381

8 m (26.2 ft.)

Dual-Cable Scale

1416-C233-0040

497-0302149

4 m (13.1 ft.)

Dual-Cable Scale

1416-C233-0080

497-0302161

8 m (26.2 ft.)

Dual-Cable Scanner

1416-C026-0040

497-0300521

4 m (13.1 ft.)

Dual-Cable Scanner

1416-C026-0080

497-0300522

8 m (26.2 ft.)

Dual-Cable Scale

1416-C028-0040

497-0300543

4 m (13.1 ft.)

Dual-Cable Scale

1416-C028-0080

497-0300544

8 m (26.2 ft.)

Dual-Cable Scanner

1416-C026-0040

497-0300521

4 m (13.1 ft.)

Dual-Cable Scanner

1416-C026-0080

497-0300522

8 m (26.2 ft.)

Dual-Cable Scale

1416-C027-0040

497-0300533

4 m (13.1 ft.)

Dual-Cable Scale

1416-C027-0080

497-0300534

8 m (26.2 ft.)

Single-Cable

1416-C011-0040

497-0300170

4 m (13.1 ft.)

Dual-Cable Scanner

1416-C011-0040

497-0300170

4 m (13.1 ft.)

Dual-Cable Scale

1416-C061-0040

497-0301144

4 m (13.1 ft.)

2552

2557

2760

OCIA

OCIA

OCIA

2950

OCIA

Scanner Only

1416-C234-0040

497-0402970

4 m (13.1 ft.)

5932

RS-232

Scanner Only

1416-C239-0040

497-0407723

4 m (13.1 ft.)

7050, 7051

OCIA

Single-Cable

1416-C012-0040

497-0300340

4 m (13.1 ft.)

Single-Cable

1416-C012-0080

497-0300341

8 m (26.2 ft.)

Dual-Cable Scanner

1416-C012-0040

497-0300340

4 m (13.1 ft.)

Dual-Cable Scanner

1416-C012-0080

497-0300341

8 m (26.2 ft.)

Dual-Cable Scale

1416-C013-0040

497-0300350

4 m (13.1 ft.)

Dual-Cable Scale

1416-C013-0080

497-0300351

8 m (26.2 ft.)