The text of a manual · part 8 of 26
NCR 7870 Scanner/Scale Release 1.0 User's Guide: Chapter 3: Site Preparation, pages 59 to 66
Pages 59 to 66 of 228, from NCR 7870 Scanner/Scale Release 1.0 User's Guide
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the NCR 7870
Page 59
Chapter 3: Site Preparation
3-17
Display Clearance If the 7870 Scanner/Scale has an integrated display, there must be adequate clearance for viewing by the customer. In the U.S. , this is a Weights and Measurements requirement. International countries should check with their appropriate local or government agency. If the checkstand design restricts viewing, the NCR 7825 Remote Display may be used to meet visibility requirements.
60
50 30
This area must be clear for viewing integrated display.
60
R0118
Item Diverter Item Diverter (Must be removable to service Scanner/Scale in Checkstand)
7.25 in. (18.4 cm)
R0131
Page 60
3-18
Chapter 3: Site Preparation
Checkstand Hole When cutting the checkstand hole, also called a cutout, take care to maintain the specified dimensions. While this is essential for all models, it is critical for units with a scale. •
For all models, the leading edge of the Top Plate must be flush or no more than 15 cm (0.06 in.) below the top of the checkstand. The trailing edge of the Top Plate must be flush with the top of the checkstand.
•
For proper scale operation, the clearance between leading and trailing edges of the Top Plate and the checkstand must be maintained.
•
For European installations, a 5.1 cm (2 in.) border must be provided around the leading edge, trailing edge, and operator side of the scanner scale. This border must contain the words “NO WEIGH AREA.”
99999
An NCR 7870-1000 may be placed in an existing cutout for an NCR 7820 and an NCR 7870-2000 may go into a cutout for the NCR 7824. Before utilizing an existing cutout, you MUST ensure that the cutout has the correct dimensions before installing the 7870.
Page 61
Chapter 3: Site Preparation
Checkstand Hole - Models 1000 & 2000
B
C
E C
D
A
Note: Spacers are to position scale in hole. They should be below the Checkstand top.
H
D
D
C
C
G
F
E B
F A
Recommended shelf to catch NCR 7870 if dropped during installation. The 7870 must not be supported by this shelf.
No electronics under NCR 7870
NCR 7870-1000 Scanner A 29.51 cm
B 50.95 cm
C 3.49 cm
D 0.95 cm
E 43.97 cm
F 3.49 cm
G 13.0 cm
H 15.88 cm
11 5/8 in. 20 1/16 in. 1 3/8 in.
3/8 in.
17 5/16 in.
1 3/8 in.
5 1/8 in.
6 1/4 in.
NCR 7870-2000 Scanner/Scale A 30.48 cm
B 50.95 cm
C 3.49 cm
D 1.27 cm
E 43.97 cm
F 3.49 cm
G 13.0 cm
H 15.88 cm
12 in.
20 1/16 in. 1 3/8 in.
1/2 in.
17 5/16 in. 1 3/8 in.
5 1/8 in.
6 1/4 in. R0119
3-19
Page 62
3-20
Chapter 3: Site Preparation
Checkstand Hole - Models 3000, 4000, & 4500
B
C
A
Note: Spacers are to position scale in hole. They should be below the Checkstand top.
D
E C
A
B
No electronics under the 7870 NCR 7870 - 3000 Scanner A
B
C
D
E
29.51 cm
34.50 cm
0.95 cm
15.88 cm
12.54 cm
11 5/8 in.
13 5/8 in.
3/8 in.
6 1/4 in.
4 15/16 in.
NCR 7870 - 4000 & 4500 Scanner/Scale A
B
C
D
E
29.51 30.48 cm
43.97 cm
1.27 cm
15.88 cm
12.54 cm
12 .00 in.
17 3/8 in.
1/2 in.
6 1/4 in.
4 15/16 in.
Note: The 7870-3000, 4000, and 4500 must sit on a shelf below the checkstand surface. It cannot be suspended like the other units. Also, the shelf should be open at the front and back.
16631
Page 63
Chapter 3: Site Preparation
3-21
Cable Lengths and Hole Sizes When selecting a cable, take care to choose one with enough length for easy routing to the NCR 7870. Also, include enough slack to allow the unit to be lifted from the cutout without disconnecting the cables. This will be beneficial while servicing the unit. Minimum hole size data is provided for making openings to pass cables through the checkstand. Ensure after drilling that there are no sharp edges which may damage the cable. The following charts provide cable length and hole size data for AC Power Cords, DC Power Cables, Interface Cables, and Remote Display Cables. The NCR 7870 can connect to any NCR Retail Terminal as well as many competitive host terminals so a comprehensive list of interface cables has been provided.
Cable Hole Diameters Cable
Minimum Hole Size
Power Cord – Outlet to Power Supply
3.18 cm (1.25 in.)
Power Cable – Power Supply to 7870
1.52 cm (0.60 in.)
Interface Cable
1.90 cm (0.75 in.)
Remote Display Cable
1.90 cm (0.75 in.)
DC Power Cable – Power Supply to 7870 Minimum Hole Diameter: 1.52 cm (0.60 in.) Cable
Cable Length
DC Power Cable
1.22 Meters (4 Feet)
Note: DC Power Cable length is not a factor if the Power Supply is mounted on the chassis of the 7870 (Models 1000 and 2000 only).
Page 64
3-22
Chapter 3: Site Preparation
AC Power Cords – Outlet to Power Supply Minimum Hole Diameter: 3.18 cm (1.25 in.) Cable
Cable Length
US Standard
3.05 Meters (10 Feet)
US Twist-Lock
3.05 Meters (10 Feet)
International Pig-Tail
3.05 Meters (10 Feet)
Japan Standard
3.05 Meters (10 Feet)
Japan Twist-Lock
3.05 Meters (10 Feet)
Australia
3.05 Meters (10 Feet)
UK, Argentina
3.05 Meters (10 Feet)
Swiss
3.05 Meters (10 Feet)
Remote Display Cables Minimum Hole Diameter: 1.90 cm (0.75 in.) Display
Cable Corporate ID
Cable Length
7825
1416-C022-0040
4 m (13.1 ft.)
1416-C022-0080
8 m (26.2 ft.)
1416-C068-0040
4 m (13.1 ft.)
1416-C068-0080
8 m (26.2 ft.)
2552, 2557
Page 65
Chapter 3: Site Preparation
3-23
Interface Cables - NCR Host Terminals Minimum Hole Diameter: 1.90 cm (0.75 in.) Host Terminal
Interface
Cable
Corporate ID
Part Number
Length
1255
OCIA
Dual-Cable Scanner
1416-C026-0040
497-0300521
4 m (13.1 ft.)
Dual-Cable Scanner
1416-C026-0080
497-0300522
8 m (26.2 ft.)
Dual Cable Scale
1416-C027-0040
497-0300533
4 m (13.1 ft.)
Dual Cable Scale
1416-C027-0080
497-0300534
8 m (26.2 ft.) 5 m (16.4 ft.)
2113
OCIA
Scanner Only
1416-C230-0050
497-0302099
2123
OCIA
Dual-Cable Scanner
2123-K315
230-0113973
Dual-Cable Scale
2123-K315
230-0113973
Dual-Cable Scanner
1416-C014-0040
497-0300361
4 m (13.1 ft.)
Dual-Cable Scanner
1416-C014-0080
497-0300362
8 m (26.2 ft.)
Dual-Cable Scale
1416-C015-0040
497-0300371
4 m (13.1 ft.)
Dual-Cable Scale
1416-C015-0080
497-0300372
8 m (26.2 ft.)
Single-Cable
1416-C016-0040
497-0300310
4 m (13.1 ft.)
Single-Cable
1416-C016-0080
497-0300311
8 m (26.2 ft.)
2126
2127
OCIA
OCIA
2151, 2152
OCIA
Scanner Only
1416-C234-0040
497-0402970
4 m (13.1 ft.)
2154, 2155
OCIA
Single-Cable
1416-C012-0040
497-0300340
4 m (13.1 ft.)
Single-Cable
1416-C012-0080
497-0300341
8 m (26.2 ft.)
Dual-Cable Scanner
1416-C012-0040
497-0300340
4 m (13.1 ft.)
Dual-Cable Scanner
1416-C012-0080
497-0300341
8 m (26.2 ft.)
Dual-Cable Scale
1416-C013-0040
497-0300350
4 m (13.1 ft.)
Dual-Cable Scale
1416-C013-0080
497-0300351
8 m (26.2 ft.)
2156, 2157
Page 66
3-24
Chapter 3: Site Preparation
Interface Cables – NCR Host Terminals (cont.) Host Terminal
Interface
Cable
Corporate ID
Part Number
Length
2170
RS-232
Scanner Only
1416-C069-0040
497-0301380
4 m (13.1 ft.)
Scanner Only
1416-C069-0080
497-0301381
8 m (26.2 ft.)
Dual-Cable Scanner
1416-C069-0040
497-0301380
4 m (13.1 ft.)
Dual-Cable Scanner
1416-C069-0080
497-0301381
8 m (26.2 ft.)
Dual-Cable Scale
1416-C233-0040
497-0302149
4 m (13.1 ft.)
Dual-Cable Scale
1416-C233-0080
497-0302161
8 m (26.2 ft.)
Dual-Cable Scanner
1416-C026-0040
497-0300521
4 m (13.1 ft.)
Dual-Cable Scanner
1416-C026-0080
497-0300522
8 m (26.2 ft.)
Dual-Cable Scale
1416-C028-0040
497-0300543
4 m (13.1 ft.)
Dual-Cable Scale
1416-C028-0080
497-0300544
8 m (26.2 ft.)
Dual-Cable Scanner
1416-C026-0040
497-0300521
4 m (13.1 ft.)
Dual-Cable Scanner
1416-C026-0080
497-0300522
8 m (26.2 ft.)
Dual-Cable Scale
1416-C027-0040
497-0300533
4 m (13.1 ft.)
Dual-Cable Scale
1416-C027-0080
497-0300534
8 m (26.2 ft.)
Single-Cable
1416-C011-0040
497-0300170
4 m (13.1 ft.)
Dual-Cable Scanner
1416-C011-0040
497-0300170
4 m (13.1 ft.)
Dual-Cable Scale
1416-C061-0040
497-0301144
4 m (13.1 ft.)
2552
2557
2760
OCIA
OCIA
OCIA
2950
OCIA
Scanner Only
1416-C234-0040
497-0402970
4 m (13.1 ft.)
5932
RS-232
Scanner Only
1416-C239-0040
497-0407723
4 m (13.1 ft.)
7050, 7051
OCIA
Single-Cable
1416-C012-0040
497-0300340
4 m (13.1 ft.)
Single-Cable
1416-C012-0080
497-0300341
8 m (26.2 ft.)
Dual-Cable Scanner
1416-C012-0040
497-0300340
4 m (13.1 ft.)
Dual-Cable Scanner
1416-C012-0080
497-0300341
8 m (26.2 ft.)
Dual-Cable Scale
1416-C013-0040
497-0300350
4 m (13.1 ft.)
Dual-Cable Scale
1416-C013-0080
497-0300351
8 m (26.2 ft.)