Page 177

Chapter 7: Programming

7-61

Codes

Description

Code 00

Label was decoded without major problems.

Code x1

Label appears to be highly underprinted.

Code x2

Label appears to be highly overprinted.

Code x4

Label appears to have missing bars or margins.

Code x5

Label appears to be highly underprinted and to have missing bars or margins.

Code x6

Label appears to be highly overprinted and to have missing bars or margins.

Code 1x

Decoding was difficult. May be due to inconsistent printing.

Code 2x

Fragmented or folded label or inconsistent printed.

Code 3x

Decoding was difficult due to fragmented, folded, or inconsistently printed label.

Code 98

Label cannot be decoded due to missing print lines.

Code 99

Label cannot be decoded. If a particular label shows this code it should be analyzed more closely for out-ofspecification conditions, even though the label may show a Code 00 when it does scan (printing may be inconsistent).

Note: If a label displays a code other than Code 00, the label should be tested further for being out of specification by using a symbol verifier. Note: To exit Mode 2 and return to Normal Mode, press the Scale Zero Button on the Operator Display Panel. To go from Mode 2 to Mode 1, scan the Mode 1 tag.

Page 178

7-62

Chapter 7: Programming

Mode 3 – Normal Mode 3 is the normal operating mode. You can program the scanner to add PACESETTER Plus information to the decoded UPC/EAN data that is sent to the host terminal. Perform the following procedure to enable or disable PACESETTER Plus information. 1. Scan the Programming Mode tag (must be first tag scanned after power-up). 2. Scan the Hex 3 tag. 3. Scan the Hex 1 tag. 4. Scan the Hex 3 tag. 5. Scan the Hex 1 tag to disable PACESETTER Plus information, or the Hex 2 tag to enable PACESETTER Plus information. 6. Scan the Save and Reset tag. The PACESETTER Plus information describes the label readability much the same way as described in Mode 2. However, the host software must be capable of receiving the extra data being sent to it. With OCIA and RS-232 communications, PACESETTER Plus information is sent as trailer information. With IBM communications, PACESETTER Plus information is sent as header information that is located between the last Status byte and the first tag data byte in the message. The PACESETTER Plus format is defined as the normal UPC/EAN format with the following added.

OCIA

RS-232

IBM

OCH, xyH, xzH

43H, 3yH, 3zH

OCH, 0yH, 0zH x = High nibble containing character parity depending on communication format (or 0). yz = Decoding code

Page 179

Chapter 7: Programming

7-63

The EOM bit, if applicable, is in the last byte sent, not the last byte of the label data. The Decoding Codes are specified in the following table.

Decoding Codes Y Z

Description

1 z

Decoding was difficult. May be due to inconsistent printing.

2 z

Fragmented or folded label or inconsistent printing.

3 z

Decoding was difficult due to fragmented, folded, or inconsistently printed label.

y

1

Label appears to be highly underprinted.

y

2

Label appears to be highly overprinted.

y

4

Label appears to have missing bars or margins.

y

5

Label appears to be highly underprinted and to have missing bars or margins.

y

6

Label appears to be highly overprinted and to have missing bars or margins.

0

0

Label was decoded without major problems.

9

9

If a particular label intermittently shows this code, the label should be analyzed more closely for out-of-specification conditions, even though the label may show a Code 00 when it does scan (printing may be inconsistent).

Page 180

7-64

Chapter 7: Programming

Host Access to Tallies The host can send Long Format Codes, Short Format Codes, RS-232 Format Codes, and IBM 4683 Format Codes to read the scanner tallies. The following table shows the Long Format Codes and the RS-232 Format Codes to use.

Tally

Long Format Codes: OCIA and Single-Cable Scanner/Scale OCIA

RS-232 Codes

C1

00H, 33H, 3DH, 32H, 31H

33H, 3dH, 32H, 31H

C2

00H, 33H, 3DH, 32H, 32H

33H, 3dH, 32H, 32H

C3

00H, 33H, 3DH, 32H, 33H

33H, 3dH, 32H, 33H

C4

00H, 33H, 3DH, 32H, 34H

33H, 3dH, 32H, 34H

C5

00H, 33H, 3DH, 32H, 35H

33H, 3dH, 32H, 35H

Note: Parity, BCC, and so on, appropriate to the communication protocol must be added.

Examples of Host Access to Tallies Example 1 Host requesting tally C3 through single-cable OCIA. 30H b3H

3dH

32H b3H

8fH

The NCR 7870 response to the host request. 30H

33H

3yH

3xH

3xH

3xH

3xH

3xH

3xH

3xH

BCC (with EOM Bit)

x = Decimal digit with high order digit sent first y = Tally count number BCC = Block Check Character - an exclusive OR of all previous bytes Presence of BCC specified by protocol

16823

Page 181

Chapter 7: Programming

7-65

Example 2 Host requesting tally C3. 30H b3H

3dH

32H b3H

8fH

The NCR 7870 response to the host request (tally count = 23,456 30H

33H

33H

30H

30H

32H

33H

34H

35H

BCC (with EOM Bit)

36H

16824

Example 3 An IBM host terminal request for tally C1. 4A xx

00

33

3D

32

31 xx xx

7E xx

32

00

00

02

03

Address Frame Request CRC Bytes (2) End Byte The NCR 7870 response to the host request. 4A xx xx xx

04

05

06

31 xx xx

7E

Scanner Address Frame Counts Scanner Status Bytes (3) Pacesetter Plus Group Code Seven Bytes BCD Data Pacesetter Plus Function Code CRC Bytes (2) End Byte 16825

Page 182

7-66

Chapter 7: Programming

Host Terminal request using short format codes: Send Tally Count

NCR OCIA

Non-NCR OCIA

C1: 03H 0dH 01H

03H 4DH 21 H With Parity & EOM

83H 0DH C1H With Parity & EOM

C2: 03H 0dH 02H

03H 4DH E3H 03H 4DH 21H

83H 0DH C2H With Parity & EOM

C3: 03H 0dH 03H

03H 4DH A3H With Parity & EOM

83H 0DH 43H With Parity & EOM

C4: 03H 0dH 04H

03H 4DH 65H With Parity & EOM

83H 0DH 24H With Parity & EOM

C5: 03H 0dH 05H

03H 4DH 65H With Parity & EOM

83H 0DH 45H With Parity & EOM

The NCR 7870 response to the host request. 00H 03H 0yH 0xH 0xH 0xH 0xH 0xH 0xH 0xH

Parity & EOM bits added.

x = Decimal digit with high order digit sent first y = Tally count number 16826

Example 4 Host request for tally C5 using short format codes: Send Tally Count

NCR OCIA

Non-NCR OCIA

C5: 03H 0dH 05H

03H 4DH 65H With Parity & EOM

83H 0DH 45H With Parity & EOM

Page 183

Chapter 7: Programming

7-67

The NCR 7870 response to the host request (tally count = 23,456): Send Tally Count

NCR OCIA

Non-NCR OCIA

00H 03H 00H 00H 02H 03H 04H 05H 06H

C0H 03H C5H C0H C0H 42H 03H 84H C5H A6H C0H 03H C0H C0H 42H 03H 84H C5H A6H C0H 03H C0H C0H 42H 03H 84H C5H A6H With Parity & EOM

80H 83H 85H 80H 80H 02H 83H 04H 85H 46H With Parity & EOM

Host Reset of Tallies The host terminal can reset the tally counts using the Long Format OCIA, Short Format OCIA, Single-Cable Scanner/Scale OCIA (parity bits, EOM bits or BCC bytes are not shown), RS-232, and IBM 4683 formats. The OCIA and RS-232 command is given in the following chart: Host terminal request to reset tally counts (OCIA & RS-232) OCIA

RS-232

00H 03H 0DH xxH

44H 43H

XxH = 00H or BBC (where protocol calls for BBC)

An IBM host terminal request to reset tally counts 4A xx

00

33

3D

3C

00 xx xx

7E

Address Frame Request CRC Bytes (2) End Byte

16827

Page 184

7-68

Chapter 7: Programming

Special Programming Some of the NCR 7870 features require programming that is somewhat different than the normal programming.

Delay Weight Data to IBM Host Terminal A timing condition is possible when the NCR 7870 Scanner/Scale communicates with an IBM host terminal. The condition occurs when the IBM Host is requesting weight data, but the scale is not settled. To prevent the problem, you can enable a scale data delay function that gives the scale more time to settle. The default for this parameter is to disable the Scale Data Delay. Enable or disable the Scale Data Delay by scanning the following sequence of programming tags as the first tags scanned after applying power to the NCR 7870. Enable – Programming Mode, Hex 4, Hex C, Hex E, Hex 2, Hex 9, Hex 4, Hex E, Hex 8, Hex 0, and Save and Reset. Disable – Programming Mode, Hex 4, Hex C, Hex E, Hex 2, Hex 9, Hex 4, Hex E, Hex 0, Hex 0, and Save and Reset.

Page 185

Chapter 7: Programming

7-69

EAN/JAN/UPC Multi-Symbol Scanning Parameters The optional Multi-Symbol programming feature permits you to scan bar code labels containing two or three EAN-13, JAN-13, or UPC-A symbols.

Label Construction A multi-symbol label must consist of any combination of two or three EAN-13, JAN-13, or UPC-A symbols, each with different flag digits. Flag digits are the first two digits of the symbol on EAN-13/JAN-13 symbols. Flag digits for UPC-A symbols always have a zero (0) for the first digit with the number system character being the second digit. There is NO restriction on which flag digits may be used except that any flag digits used in a 3-symbol combination cannot be used in any of the 2-symbol combinations, and any flag digits used in a 2-symbol combination cannot be used in any of the 3-symbol combinations. A mixture of 2-symbol and 3-symbol combinations is allowed. A total of five multi-symbol combinations can be programmed.

Single Label Restriction A single-symbol with the same flag digits as programmed for any 2symbol or 3-symbol labels cannot be scanned as a single-symbol label.

Transmitting Label Data Transmission of a multi-symbol label consists of a separate message for each of the symbols. The symbol with the lower numbered flag digits is transmitted first. For example, for the 3-symbol combination of JAN13 flag 21, JAN-13 flag 29, and JAN-13 flag 96, the symbol with flag digits 21 is transmitted first, the symbol with flag digits 29 is transmitted second, and the symbol with flag digits 96 is transmitted third.

Page 186

7-70

Chapter 7: Programming

Perform the following to program the NCR 7870 for multi-symbol scanning. 1. Disconnect the communications cable from the scanner or the terminal. 2. Apply power to the NCR 7870. 3. To enter the Multi-Symbol program parameters mode, scan the following tags: Programming Mode, Hex 1, Hex 3, and Hex F. 4. Choose an option: Option A: Clear multi-symbol programming by scanning the Hex A tag and the Save and Reset tag. Result: All previously programmed combinations are cleared from permanent memory. The scanner goes through a sequence similar to the power up sequence. Option B: Program a 2-symbol label by scanning the Hex 2 tag. Result: The scanner sounds two beeps followed by a 1second pause. After the pause, the scanner beeps to indicate the number of labels that are currently in the scanner memory. Five beeps indicate a full multisymbol memory. Option C: Program a 3-symbol label by scanning the Hex 3 tag. Result: The scanner sounds three beeps followed by a 1-second pause. After the pause, the scanner beeps to indicate the number of labels that are currently in the scanner memory. Five beeps indicate a full multisymbol memory. Option D: Scan a multi-symbol label (2-symbol label if you scanned the Hex 2 tag or 3-symbol label if you scanned the Hex 3 tag).