Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 19 of 26

NCR 7870 Scanner/Scale Release 1.0 User's Guide: Chapter 7: Programming, pages 167 to 176

Pages 167 to 176 of 228, from NCR 7870 Scanner/Scale Release 1.0 User's Guide

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the NCR 7870

Page 167

Chapter 7: Programming

7-51

Following is the normal (default) format for scanner/scale tag data messages. •

Scanner/Scale Tag Data

•

Message Format

Prefix Byte

30

38

Add

FC

Label Identifier

Tag Data

PPD

Terminator Byte

BCC Byte

Shading indicates optional information. 16565

The difference between the scanner only and the scanner/scale format is that the scanner/scale format has an address and a function code following the optional Prefix Byte. For more detailed information on message formats refer to the NCR Scanner/Scale Interface Programmer's Guide (BD20-1074-A).

Beep at Scale Weight Transmission This parameter allows the scanner to signal the transmission of a scale weight that was requested by the host terminal. Scanning the Hex 9 tag activates this feature and causes the unit to sound a Good Read tone as the weight information is sent to the terminal.

Page 168

7-52

Chapter 7: Programming

Program Example Following is an example of a completed RS-232 Communications Options programming worksheet. This example shows the following programming selections. •

Message delay – 10 ms

•

Format – Scanner only

•

Normal or Eavesdrop – Normal Mode

•

Scale Weight Transmission - Beep

Your Program

2

A

B

C

D

Message Delay

Scanner or Scanner/Scale Format

Normal or Eavesdrop Mode

Beep/No Beep Scale Weight Transmission

4

RS-232 Communications Options

12164

Page 169

Chapter 7: Programming

7-53

Scale Parameters The Scale Parameters programming mode controls specific parameters associated with the NCR 7870-2000, 4000, 4500 Scales. You can use it to identify if the NCR 7870 includes a scale, and to define the address if the scale is connected to an IBM terminal.

Defaults Parameter

Default Value

Model Number

No Default

9.995 kg/13.995 kg

No Default

IBM Address

Address 6E set by selecting IBM 468x on Communications Protocol Worksheet

Specific Program Parameters Model Number The Model Number parameter specifies if your unit is an NCR 78701000/3000 Scanner or an NCR 7870-2000, 4000, or 4500 Scanner/Scale. This parameter is set at the factory and should not need changing under normal circumstances. Scan the Hex 3 tag to specify that the unit is an NCR 7875-2000, 4000, or 4500 (scanner and scale), or scan the Hex 4 tag to specify the unit as being an NCR 7875-1000 or 3000 (scanner only). If you disable the scale on an NCR Scanner/Scale unit by scanning the Hex 4 tag, the BCC option also changes to the appropriate state. IBM Address When programming an NCR 7870-2000, 4000, or 4500 Scanner/Scale for IBM communications, you must select the proper scale communications address. Selecting the IBM 468x communications

Page 170

7-54

Chapter 7: Programming protocol sets the scale address to 6E; however, it may need to be changed to 6A or 6B, depending on the IBM configuration in the particular IBM customer retail application. Scan the Hex 5 tag for address 6A, the Hex 6 tag for address 6B, or the Hex 7 tag for address 6E. The IBM terminal integrated scanner/scale driver normally uses address 6E. However, if the scanner works but the scale does not, you should try using the other two scale addresses. 9.995 kg / 13.995 kg The 9.995 kg / 13.995 kg parameter toggles between a maximum weight of either 9.995 kg or 13.995 kg. Use the Hex B tag to toggle between the two weights.

Program Example Following is an example of a completed Scale Parameters programming worksheet. This example shows the following programming selections. •

Weight – displayed in kilograms

•

Unit – NCR 7870-2000 Scanner/Scale

•

IBM address – 6B

•

9.995 kg / 13.995 kg – the Hex B tag toggles this parameter

Your Program

3

0

Scale Parameters

Model Number

IBM Address

9.995 kg / 13.995 kg

R0140

Page 171

Chapter 7: Programming

7-55

Miscellaneous Parameters The Miscellaneous Parameters programming mode controls parameters associated with the NCR 7870-2000, 4000, and 4500 Scales that do not fit easily into any of the other categories. The NCR 7870 firmware is programmed to accept one parameter at a time and then leave this programming mode. Therefore, each of the parameters must be programmed separately.

Defaults Parameter

Default Value

5-Second Weight Display Timer

Enabled

IBM Tone Control

Enabled

OCIA Price Display

Enabled

IBM Rexmit Control

Permanently Enabled

OCIA Blank Display in Price Mode

Disabled

Enable/Disable Voice Messages

No Default

IBM Tag Data Format

Hex

Specific Program Parameters 5-Second Weight Display Timer This timer controls how long a price is shown on the integrated or remote display. The 5-Second Weight Display Timer will only work if the NCR 7870 is in OCIA Price Display Mode. The OCIA Blank Display may or may not be enabled –- it is optional. When the 5-Second Weight Display Timer is enabled (which is the default setting), the display will show a weight until the host terminal sends a price. The price is displayed for no more than five seconds before returning back to weight. The weight value will remain on the display until new information is sent to the display, e.g. – an item is

Page 172

7-56

Chapter 7: Programming scanned or a weight change is registered by the scale. Use the Hex 2 tag to enable the timer. When the 5-Second Weight Timer is disabled, the display will show a weight value until the host terminal sends price information. The price will remain on the display until new weight or price information is sent to the display. Use the Hex 1 tag to disable the timer. IBM Tone Control (Good Read Tone) When you use an IBM terminal, this parameter determines what device controls the tone. Scanning the Hex 4 tag enables this option and the IBM terminal controls the tone. Scanning the Hex 3 tag disables this option and the scale controls the tone. OCIA Price Display When you use an OCIA terminal, this parameter controls the price display. If you select enable by scanning the Hex 6 tag, the scale accepts and displays price information from the terminal. If you select disable by scanning the Hex 5 tag, the scale does not accept or display any price information. IBM Rexmit Control When you use an IBM terminal and the scale detects a bad message from the terminal, this parameter controls how the original message gets retransmitted. If you select enable by scanning the Hex 7 tag, the scale retransmits the original message three times, and then terminates the sequence. If you select forever by scanning the Hex 8 tag, the scale retransmits the original message until it is accepted, or until the scale is told to reset by the terminal. You should not use the enable selection unless advised to do so by NCR to solve a problem. OCIA Blank Display In Price Mode When Price Display mode is enabled, the OCIA Blank Display in Price Mode parameter controls how the scale reacts to blank screen commands. If you select enable by scanning the Hex A tag, the scale blanks the screen when it receives the command. If you select disable by scanning the Hex 9 tag, the scale ignores the command.

Page 173

Chapter 7: Programming

7-57

Enable/Disable Voice Messages When you have the voice messages feature on your scanner/scale, the Voice Messages Enabled/Disabled parameter toggles to enable or disable the feature. If voice messages are enabled, you hear them at the appropriate time. If they are disabled, you hear the beep tones instead. The Hex D tag toggles this parameter between enabled and disabled. There is no indication, visual or otherwise, of the state of the enable/disable condition. If you do not hear the voice messages when you expect to hear them, toggle this parameter. If you still do not hear them, the problem could be in the programming ROM, the speaker chip, or elsewhere. IBM Tag Data Format This option is included because most IBM devices that have a select address of 4B require the bar code data to be transmitted as ASCII characters. (For hand-held bar code readers, see Communications Protocol Programming Mode.) Therefore, when selecting Communications Protocol choice 4B, NCR recommends that you set the tag format to ASCII. Use the Hex E tag to select hex and use the Hex F tag to select ASCII. The hex format is the default.

Program Example Following is an example of a completed Miscellaneous Parameters programming worksheet showing the following programming selections. •

5-Second Weight Display Timer – disabled

•

IBM Tone Control – disabled

•

OCIA Price Display – enabled

•

IBM Rexmit Control – 3 times

•

OCIA Blank Display in Price Mode – enabled

•

Enable/Disable Voice Messages – the Hex D tag toggles this parameter

•

IBM Tag Data Format – ASCII

Page 174

7-58

Chapter 7: Programming

Your Program

3

2

Miscellaneous Parameters

1

5-Second Weight Display Timer

3

IBM Tone Control

6 7

OCIA Price Display

IBM Rexmit Control

A

OCIA Blank Display in Price Mode

D

Toggle Enable/Disable of Voice Messages

F

IBM Tag Data Format 11822

Page 175

Chapter 7: Programming

7-59

PACESETTER Plus Information The PACESETTER Plus optional feature of the NCR 7870 Scanner/Scale determines what is wrong with a bar code label, fixes it, and then transfers the information to the host terminal. In addition, the scanner keeps track of what is wrong with the labels.

Mode 1 - Inquiry Mode 1 keeps the following tallies. Included are the maximum counts.

Tally Count Type

Description

Maximum Count

C1

Good Reads

1,000,000

C2

No reads due to lack of a full label (bars missing, folded label, etc.)

65,535

C3

Good reads with very highly overprinted bars

65,535

C4

Good reads with very highly underprinted bars

65,535

C5

Missing margins

65,535

Enter Mode 1 by scanning the Mode 1 tag. Tally counts are displayed on the Integrated Display or the NCR 7825 Remote Display. First the display shows the tally count number and the percentage of that count to the number of good reads. Three seconds later the actual tally count is displayed. This cycle continues every three seconds.

Page 176

7-60

Chapter 7: Programming

C3

1136

03.4

Tally Count 3 3.4% of Good Reads

Tally Count = 1136

Note: These displays alternate every three seconds. 16566

Scanning the Mode 1 tag again changes the display sequence to the next tally count. Continue to scan the Mode 1 tag to view all tally counts. The tally count information is displayed in order according to the tally count number (C1 – C5). Exit Mode 1 by pressing the Scale Zero Button on the Operator Display Panel or by scanning the Mode 2 tag.

Mode 2 - Real Time Enter Mode 2 by scanning the Mode 2 tag. The scanner goes off-line and disables the scale so that the integrated display or the NCR 7825 Remote Display can show Ready 4 label. Every subsequent scan until the scanner is powered off (or the Scale Zero Button is pressed) causes the scanner to indicate the status of label readability. The scanner can recognize missing bars in labels, highly over/under printed labels, missing margins, or a no-read condition. If you scan a UPC/EAN label for analysis, the display shows label followed in one second by the display of the first half of the UPC/EAN label. If the label is a version E, no second half is displayed, since the E label is only six digits in length. After another two-second pause, the display shows CODE xx where "xx" is a code number to indicate one of the following.