The text of a manual · part 10 of 26
NCR 7870 Scanner/Scale Release 1.0 User's Guide: Chapter 4: Installation
Pages 75 to 86 of 228, from NCR 7870 Scanner/Scale Release 1.0 User's Guide
The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the NCR 7870
Page 75
Chapter 4: Installation
Getting Started This chapter describes the installation process for the NCR 7870. Before installation, prepare the site in accordance to the requirements in Chapter 2 – Site Preparation. The first step is to perform an inspection to verify that the unit and checkstand are ready.
Reporting a Damaged Unit Upon receiving an NCR 7870, inspect the shipping for damage. If the carton is damaged, open it in the presence of the shipping carrier before signing the bill of lading. If the scanner/scale has been damaged due to shipping, notify the carrier and an NCR representative. If the unit was not purchased directly from NCR, notify your supplier.
What’s in the Box Unpack the unit according to the instructions on the box. Inventory the contents to ensure you have received the following components. •
NCR 7870
•
Power Cord
•
Top Plate
•
Documentation
•
Country Language Specific IEC Class 1 Laser Labels (International Units)
•
Metal Foil Stamping Plate (200x Model International Units)
•
Power Cord Documents (International Units)
•
Interface Cable (when cable feature requested with order)
Page 76
4-2
Chapter 4: Installation
Cable Verification The NCR 7870 can be used with many different host terminals. Verify that you have received the correct interface cable (some set-ups require two cables). A list of available interface cables is provided in the NCR 7870 Repair Guide (BD20-0966-A).
Checkstand Verification Verify, as a minimum, that the checkstand is prepared according to the following. •
Checkstand cutout is correct size.
•
Display and service clearances are adequate.
•
Checkstand is properly wired.
•
Power cord is correct for unit and electrical outlet.
Page 77
Chapter 4: Installation
4-3
Installing Unit in Checkstand The NCR 7870 is fully assembled at the factory and requires no operator assembly. The laser module is an integral part of the factory assembled device and does not have any controls that can increase the level of laser light or collateral radiation from the NCR 7870.
Instructions Install Cables 1. Verify power receptacle switch is off. 2. Turn NCR 7870 on its side. 3. Route power cable through groove on bottom of unit. 4. Return unit to upright position. 5. Place unit so a portion of the tower is directly over the cutout in the checkstand counter. 6. Pass Power Cord down through cutout and plug into dedicated NCR power receptacle. 7. Connect communication interface cables to host terminal or PC. Because installation varies from one terminal to another, refer to your host terminal’s documents for specific information on interface cable connection. Note: A trained service technician may be required to open some host terminals to connect the interface cables. 8. Connect interface cables to NCR 7870. Four interface connectors are located on the rear side of the Tower Cabinet. These are for the •
REMOTE DISPLAY – used to connect the NCR 7825 Remote Display, which is for price and weight information.
•
SCANNER (or RS-232) – used to connect interface cable on single cable installations or the scanner.
Page 78
Chapter 4: Installation
•
TERMINAL DISPLAY – Not used.
•
SCALE (or Datachecker) – used to connect the scale interface cable on dual cable installations.
9. See following diagrams for installation information for single, dual cable, and Datachecker/RS-232 set-ups.
Power Cord
Power Cable
Remote Display
Interface Cable
Host Terminal
SCALE
TERMINAL DISPLAY
SCANNER
REMOTE DISPLAY
Single Cable Set-Up
DC POWER
4-4
Page 79
Chapter 4: Installation
SCALE SCALE
DISPLAY DISPLAY INPUT INPUT
SCANNER
DISPLAY DISPLAY OUTPUT OUTPUT
DC DC POWER POWER
Dual Cable Set-Up
AC Power Cord
7870 Scanner/Scale
Power Supply Remote Display
DC Power Cable
Interface Cable
Display Cable Host Terminal
Interface Cable
4-5
Page 80
Chapter 4: Installation
DATACHKR
TERMINAL DISPLAY
RS-232
REMOTE DISPLAY
Datachecker or RS-232 Cable Set-Up
DC POWER
4-6
Interface Ports Label
Power Cord
Power Cord
Interface Cable Terminal Junction Box
Host Terminal
11628
Note: Use the Terminal Junction Box as needed to provide additional ports. Contact your terminal vendor for ordering information. 10. If the checkstand counter has adjustable posts to support the NCR 7870, set to the following: •
Scanner Only Models:
0.95 cm (0.375 in.) deep
•
Scanner/Scale Models:
1.27 cm (0.50 in.)
If fixed flanges are used, ensure they are at the appropriate height.
Page 81
Chapter 4: Installation
4-7
11. Locate small plastic Cover inset in Subplate Assembly. Carefully release Cover.
Tower
Subplate Assembly
Cover/Lift Strap 11189
12. Use Cover/Lift Strap to lift the unit. 13. Position unit over checkstand cutout. 14. Lower unit into cutout. For proper operation, the NCR 7870 must be level. It should have support within two inches of each corner to prevent rocking. Also, the leading edge of the Top Plate must be flush or up to 0.15 cm (0.06 in.) below the counter top. The trailing edge of the Top Plate must be flush with the checkstand. Note: The four adjustable support posts on the Scale Hinge Assembly are set at the factory. Do NOT attempt to adjust the Top Plate by using these posts. 15. Replace Cover. 16. Place Top Plate on the four supports (plastic caps for scanners, rubber bumpers for scanner/scales). 17. Turn ON the unit using the circuit breaker switch. End of Procedure
Page 82
4-8
Chapter 4: Installation
Determining if the Unit is Operational When power is applied to the NCR 7870 Scanner/Scale, it automatically performs Level 0 Diagnostics to check various components.
NCR 7870-1000 and 3000 Scanners After passing Level 0 diagnostics the Status indicator flashes green, a tone sounds, then the Status indicator turns red. The NCR 7870 is now operational.
NCR 7875-2000, 4000, and 4500 Scanner/Scales After passing Level 0 diagnostics the NCR 7870 runs scale diagnostics. During this time, all segments on the integrated or remote display are turned ON so the operator can verify the display works correctly. Then the display reads Ready 0.000 kg (Ready 0.00 lb). The Status Indicator flashes red for five seconds, then the Status indicator flashes green momentarily, a tone sounds, and the Status indictor turns red. The NCR 7870 is now operational.
If the NCR 7870 Does Not Pass Level O Diagnostics If an error occurs during Level 0 diagnostics, the integrated or remote display (if the unit has one) displays an error code, and if enabled, the NCR 7870 emits an audible description of the error and what action to take. There may be some simple steps you can take to correct the problem. See Chapter 8: Troubleshooting. If you cannot correct the problem, contact NCR for warranty information.
Page 83
Chapter 4: Installation
4-9
Checkout Reading Operation To check the tag reading operation of the NCR 7870, attempt to read a good tag on an item. The Status indicator turns red when the NCR 7870 is ready to scan a label. A good read is indicated when the Status indicator turns green and a tone sounds (if enabled).
Programming Your NCR 7870 comes from the factory with the programming parameters set to default values. The Communications Protocol is set to the specifications on your order. However, you may want to make some parameter changes for your particular installation. See Chapter 7: Programming.
Page 84
4-10
Chapter 4: Installation
Determining Communications Protocol Use the following procedure to determine the communications protocol programmed in your NCR 7870. 1. Apply power to the NCR 7870. 2. Scan the Diagnostic Mode tag -- must be first tag scanned after applying power. 3. Scan the Hex 3 tag. The good read tone for this tag sounds (three beeps). If the NCR 7870 has the Voice feature enabled, the communications protocol is given audibly. If the Voice feature is not enabled, the Status Indicator flashes green and the tone beeps, identifying the communication protocol. Tone
Communications Protocol
Hex Code
1 short, highpitched beep
OCIA NCR Short
100
1 beep
OCIA NCR Long
101
2 beeps
IBM 468x/9x Port 4A (Slot Scanner)
102
3 beeps
IBM 468x/9x Port 4B (HHBRC)
103
4 beeps
IBM 468x/9x Port 4B (HHBCR)
104
6 beeps
RS-232
105
7 beeps
OCIA Single Cable
106
8 beeps
OCIA NCR Dual Cable
107
11 beeps
Casio 4-Bit, Parallel, Dual Cable
10A
12 beeps
IBM 1520 (BRC)
10B
13 beeps
TEC 4-Bit, Parallel, Dual Cable
10C
4. Remove power from 7870.
Page 85
Chapter 4: Installation
4-11
Scale Address for IBM Most IBM systems have software called Integrated Scanner/Scale that permits a single-cable installation. You can check the terminal configuration at the controller to be sure this IBM option is activated. Once chosen, the scale address is 6E (default setting), and no other action is required other than plugging the NCR 7870 interface cable into port 17 (468x). This is the preferred and most common configuration. For the 4682/469x series IBM terminals, the NCR 7870 interface cable plugs into port 9B. This series has no port 17. Some older 468x systems require a dual-cable system, where one cable connects to the scanner and the other connects to the scale. The scale cable usually plugs into port 21 of a "B" or "C" feature card. It is possible to preserve the existing terminal configuration and still use the single-cable feature of the NCR 7870. If there are no other ports used on the "B" or "C" feature card, you can remove the feature card from the terminal even though it is configured to be installed. •
If the card was in slot 2A, program the NCR 7870 scale address to 6A and plug the NCR 7870 Interface Cable into port 17.
•
If the card was in slot 2B, program the NCR 7870 scale address to 6B and plug the NCR 7870 Interface Cable into port 17.
•
If other ports beside port 21 are used on the "B" or "C" card and the other card slot is empty (2A or 2B), you can still use this procedure but the terminal configuration must be changed to define that there is a card in the empty slot and that its port 21 is connected to a scale. Program the scale to the empty slot address (2A = 6A, 2B = 6B). The existing card port 21 must be configured as not used and must not be removed from the terminal.
•
If both card slots are used on the terminal, the terminal software must be a version that can be configured to support an integrated scanner/scale. This may require upgrading the software.
Page 86
4-12
Chapter 4: Installation