Page 17

Chapter 1 Getting Started Introduction This chapter lists the parts and accessories for the wearable terminal and explains how to install and charge the batteries and start the wearable terminal for the first time.

Power Button

Display

Charge Status LED Application Keypad

Data Entry Keypad

Speaker

Action Keypad Interface Connector Rubber Plug

Battery

Battery Release

Cleat Cradle Connector

Figure 1-1 WT4070/90 Wearable Terminal

Interface Connector (shown without Rubber Plug)

Page 18

1-2

WT4070/90 Wearable Terminal User Guide

Table 1-1 Parts of the WT4070/90

Item

Description

Display

Displays the application and data stored on the device.

Power Button

Places the wearable terminal in to the suspend mode or resumes normal operation. Performs a warm boot when held down for five seconds. See Resetting the Wearable Terminal on page 2-14 for information about performing a warm boot.

Charge Status LED

Indicates the charging status of the battery.

Speaker

Provides audio playback.

Keypads

Enable user input.

Battery

Provides power to the wearable terminal.

Interface Connector

Provides electrical connection to an accessory, such as a scanner.

Cradle Connector

Provides electrical connection to a cradle.

Battery Release

Releases the battery for removal.

Cleat

Provides mounting for the wrist mount and cradles.

Unpacking the Wearable Terminal Carefully remove all protective material from around the wearable terminal and save the shipping container for later storage and shipping. Verify that you received all equipment listed below:

• Wearable terminal • Lithium-ion battery • Regulatory Guide • Quick Start Guide. Inspect the equipment for damage. If you are missing any equipment or if you find any damaged equipment, contact the Symbol Global Interactive Center immediately. See page xiii for contact information.

Page 19

Getting Started

1-3

Accessories Table 1-2 lists the major accessories available for the wearable terminal: Table 1-2 Wearable Terminal Accessories

Accessory

Description

Single Slot USB Cradle

Charges the wearable terminal main battery and a spare battery. It also synchronizes the wearable terminal with a host computer through a USB connection.

Four Slot Ethernet Cradle

Charges up to four wearable terminals (with main battery installed) and provides communication through an Ethernet connection.

Four Slot Spare Battery Charger

Charges up to four spare batteries.

RS409 Scanner

Provides scanning capability.

RS309 Scanner

Provides scanning capability.

Wrist Mount

Provides a means for wearing the wearable terminal on the arm for hands-free applications.

Hip Mount

Provides a means for wearing the wearable terminal on a belt for hands-free applications.

Headset

For audio playback/recording during voice-enabled applications.

Headset Adapter

Connects an optional headset with a barrel jack connector to the wearable terminal.

Replacement Batteries

Standard Capacity Battery: 2330 mAh

Software

Symbol Mobility Developer Kits available at: http://support.symbol.com. Device Configuration Package (DCPforWT40x0c50) and Platform SDK (PSDK40x0c50) for WT40x0, available at: http://support.symbol.com.

Scan LED Connector Rotating Scan Assembly Exit Window

Ring Mount Finger Strap

Trigger Assembly Scan Trigger

Figure 1-2 RS409 Scanner

Page 20

1-4

WT4070/90 Wearable Terminal User Guide

Protective Cap

Scan LED Trigger Connector

Interface Connector

Exit Window

Trigger Cable

Scan Button

Interface Cable

Figure 1-3 RS309 Scanner

Page 21

Getting Started

1-5

Getting Started In order to start using the wearable terminal for the first time:

• Install the main battery • Charge the main battery and backup battery • Install the wearable terminal onto the wrist mount • Install an optional scanner • Start the wearable terminal. NOTE

The main battery can be charged before or after installation into the wearable terminal. Use the Single Slot USB cradle or Four Slot Spare Battery Charger to charge the main battery before installation, or the Single Slot USB cradle or Four Slot Ethernet cradle to charge the main battery after installation.

Installing and Removing the Main Battery Installing the Main Battery Before using the wearable terminal, install a lithium-ion (Li-ion) battery by placing the battery into the wearable terminal as shown in Figure 1-4. NOTE

Ensure the battery is fully inserted. An audible click can be heard as the battery is fully inserted. A partially inserted battery may result in unintentional data loss.

When a battery is installed in a wearable terminal for the first time the wearable terminal boots and powers on automatically.

Figure 1-4 Installing the Main Battery

Page 22

1-6

WT4070/90 Wearable Terminal User Guide

Charging the Battery CAUTION

Ensure that you follow the guidelines for battery safety described in Battery Safety Guidelines on page 4-2.

Charging the Main Battery and Memory Backup Battery Before using the wearable terminal for the first time, charge the main battery until the amber Charge Status LED remains lit (see Table 1-3 on page 1-6 for charge status indications). The wearable terminal is equipped with a memory backup battery which automatically charges from the main battery whether or not the wearable terminal is operating or is in suspend mode. The memory backup battery retains data in memory for at least 30 minutes when the wearable terminal's main battery is removed or fully discharged. When the wearable terminal is used for the first time or after the memory backup battery has fully discharged, the memory backup battery requires approximately 15 hours to fully charge. Do not remove the main battery from the wearable terminal for 15 hours to ensure that the memory backup battery fully charges. If the main battery is removed from the wearable terminal or the main battery is fully discharged, the memory backup battery completely discharges in several hours. When the wearable terminal reaches a very low battery state, the combination of main battery and backup battery retains data in memory for at least 24 hours. NOTE

Do not remove the main battery within the first 15 hours of use. If the main battery is removed before the backup battery is fully charged, data may be lost.

Charge the wearable terminal with an installed main battery using either the Single Slot USB cradle or the Four Slot Ethernet cradle. To charge the main battery: 1.

Ensure the cradle used to charge the main battery is connected to the appropriate power source.

2.

Insert the wearable terminal into a cradle.

3.

The wearable terminal starts to charge automatically. The amber Charge Status LED lights to indicate the charge status. See Table 1-3 for charging indications. The standard capacity battery fully charges in less than four hours.

Table 1-3 Wearable Terminal LED Charge Indicators

LED

Indication

Off

Wearable terminal is not in cradle. Wearable terminal not placed correctly. Charger is not powered.

Fast Blinking Amber

Charging error: • Temperature is too low or too high. • Charging has gone on too long without completing (typically eight hours).

Slow Blinking Amber

Wearable terminal is charging.

Solid Amber

Charging complete. Note: When the battery is initially inserted in the wearable terminal, the amber LED flashes once if the battery power is low or the battery is not fully inserted.

Page 23

Getting Started

1-7

Charging Spare Batteries Use the following accessories to charge spare batteries:

• Single Slot USB Cradle • Four Slot Spare Battery Charger. To charge a spare battery: 1.

Ensure the accessory used to charge the spare battery is connected to the appropriate power source.

2.

Insert the spare battery into the accessory’s spare battery charging slot with the charging contacts facing down (over the charging pins) and gently press down on the battery to ensure proper contact.

3.

The battery starts to charge automatically. The amber charge LED on the accessory lights to show the charge status. See Chapter 3, Accessories for accessory charge LED indicator definitions.

The standard capacity battery fully charges in less than four hours.

Removing the Main Battery To remove the main battery: 1.

Prior to removing the battery, ensure that the wearable terminal is in suspend mode. If the wearable terminal is not in suspend mode, press the Power button to place the wearable terminal in suspend mode.

2.

Press the battery release button. The battery partially ejects from the wearable terminal.

3.

Remove the battery from the wearable terminal.

Battery Release

Figure 1-5 Removing the Main Battery

Page 24

1-8

WT4070/90 Wearable Terminal User Guide

Installing the Wrist Mount The wrist mount provides the mounting of the wearable terminal on the forearm for hands-free applications. Refer to the Wrist Mount Installation Guide for information on the wrist mount.

Mounting Bracket

Release Lever Figure 1-6 Wrist Mount

To install the wrist mount: 1.

Determine which arm the wrist mount will be used on.

2.

Install the short strap on the end closest to the wrist.

3.

Install the long strap on the other end.

4.

Slide the hand into the wrist mount.

5.

Tighten the straps.

6.

Align the cleat on the back of the wearable terminal with the mounting bracket on the wrist mount.

Mounting Bracket

Figure 1-7 Aligning the Cleat 7.

Slide the wearable terminal onto the wrist mount until it clicks into place.

8.

If necessary, loosen and re-tighten the straps.

Page 25

Getting Started

1-9

Figure 1-8 Wearable Terminal and Wrist Mount

To remove the wearable terminal from the wrist mount, press down on the release lever and slide the wearable terminal out.

Release Lever Figure 1-9 Wearable Terminal Removal

Page 26

1 - 10 WT4070/90 Wearable Terminal User Guide

Connecting a Scanner The RS309 and RS409 scanners can be used with the wearable terminal. Refer to RS309 Scanner on page 3-9 and RS409 Scanner on page 3-7 for procedures for connecting the scanner to the wearable terminal.

Starting the Wearable Terminal Press the Power button to turn on the wearable terminal. If the wearable terminal does not power on, perform a cold boot. See Resetting the Wearable Terminal on page 2-14. NOTE

When a battery is fully inserted in a wearable terminal for the first time, upon the wearable terminal’s first power up, the device cold boots and powers on automatically.

When the wearable terminal is powered on for the first time, it initializes its system. The Symbol splash screen (Figure 1-10) appears for a short period of time followed by the Start Up window.

Figure 1-10 Symbol Splash Screen

OEM VERSION 02.17.0001

Figure 1-11 Start Up Window

OEM VERSION 03.17.0001

OEM VERSION 04.20.0004 or 05.30.0001