Page 43

CHAPTER 4 USER PREFERENCES & MISCELLANEOUS OPTIONS Introduction You can program the digital scanner to perform various functions, or activate different features. This chapter describes each user preference feature and provides programming bar codes for selecting these features. The digital scanner ships with the settings shown in Table 4-1 on page 4-2 (also see Appendix A, Standard Default Parameters for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the digital scanner is powered down. NOTE

Most computer monitors allow scanning the bar codes directly on the screen (when using the imaging engine). When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces are not merging.

If not using a USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host. To return all features to default values, scan the Set Default Parameter on page 4-4. Throughout the programming bar code menus, asterisks indicate (*) default values.

* Indicates Default

*High Volume

Feature/Option

(00h) Option Hex Value

Page 44

4-2

DS9208-1D Product Reference Guide

Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high, scan the High Frequency (beeper tone) bar code listed under Beeper Tone on page 4-6. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Serial Response Timeout or Data Transmission Formats, require scanning several bar codes. See these parameter descriptions for this procedure.

Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.

User Preferences/Miscellaneous Options Parameter Defaults Table 4-1 lists defaults for user preferences parameters. To change the default values, scan the appropriate bar codes in this guide. These new values replace the standard default values in memory. To recall the default parameter values, scan the Set Default Parameter on page 4-4. NOTE

Table 4-1

See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.

User Preferences Parameter Defaults Parameter

Parameter Number

Default

Page Number

User Preferences Set Default Parameter

Set Defaults

4-4

Parameter Bar Code Scanning

ECh

Enable

4-5

Beep After Good Decode

38h

Enable

4-5

Beeper Tone

91h

Medium

4-6

Beeper Volume

8Ch

High

4-7

Volume Adjustment Trigger Timeout

F0h 93h

5.0 Sec

4-8

Beeper Duration

F1h 74h

Medium

4-9

Suppress Power-up Beeps

F1h D1h

Do not suppress

4-9

Low Power Mode

80h

Disable

4-10

Time Delay to Low Power Mode

92h

1 Hour

4-11

Trigger Mode

8Ah

Presentation

4-13

Trigger Aiming Pattern

F0h 32h

Enable

4-14

Presentation Aiming Pattern

F1h 4Eh

Disable

4-15

Momentary Trigger Mode Timeout

EDh

5 sec

4-16

Motion Detect Range

F2h 3Bh

Full

4-17

Page 45

User Preferences & Miscellaneous Options

Table 4-1

User Preferences Parameter Defaults (Continued) Parameter

Parameter Number

Default

Page Number

Decoding Illumination (Hand-Held Mode Only)

F0h, 2Ah

Enable

4-18

Post Decode Illumination

F2h 29h

Always Off

4-18

Illumination Always On (Presentation Mode Only)

F2h 59h

Illumination Automatically Controlled

4-19

Presentation Mode Field of View

F1h 61h

Full

4-20

Picklist Mode

F0h 92h

Enabled in Trigger Mode

4-21

Continuous Bar Code Read

F1h 89h

Disable

4-22

Unique Bar Code Reporting

F1h D31h

Disable

4-22

Decode Session Timeout

88h

9.9 Sec

4-23

Timeout Between Decodes, Same Symbol

89h

0.3 Sec

4-23

Timeout Between Decodes, Different Symbols

90h

0.2 Sec

4-24

Fuzzy 1D Processing

F1h 02h

Enable

4-24

Motion Tolerance (Hand-Held Trigger Modes Only)

F2h 5Ah

Less Motion Tolerance

4-25

Transmit Code ID Character

2Dh

None

4-26

Prefix Value

63h, 69h

7013 <CR><LF>

4-27

Suffix 1 Value Suffix 2 Value

62h 68h 64h 6Ah

7013 <CR><LF>

4-27

Scan Data Transmission Format

EBh

Data as is

4-28

FN1 Substitution Values

67h 6Dh

Set

4-29

Transmit “No Read” Message

5Eh

Disable

4-30

Miscellaneous Options

4-3

Page 46

4-4

DS9208-1D Product Reference Guide

User Preferences Set Default Parameter You can reset the digital scanner to two types of defaults: factory defaults or custom defaults. Scan the appropriate bar code below to reset the digital scanner to its default settings and/or set its current settings as custom defaults.

• Set Defaults - Scan this bar code to reset all default parameters as follows. • If you previously set custom defaults by scanning Write to Custom Defaults, scan Set Defaults to retrieve and restore the digital scanner’s custom default settings. • If you did not set custom defaults, scan Set Defaults to restore the factory default values listed in Table A-1.

• Set Factory Defaults - Scan this bar code to restore the factory default values listed in Table A-1. This deletes any custom defaults set.

• Write to Custom Defaults - Scan this bar code to set the current digital scanner settings as custom defaults. Once set, you can recover custom default settings by scanning Set Defaults.

*Set Defaults

Set Factory Defaults

Write to Custom Defaults

Page 47

User Preferences & Miscellaneous Options

4-5

Parameter Bar Code Scanning Parameter # ECh To disable the decoding of parameter bar codes, including the Set Defaults parameter bar codes, scan the Disable Parameter Scanning bar code below. To enable decoding of parameter bar codes, scan Enable Parameter Scanning.

*Enable Parameter Bar Code Scanning (01h)

Disable Parameter Bar Code Scanning (00h)

Beep After Good Decode Parameter # 38h Scan a bar code below to select whether or not the digital scanner beeps after a good decode. If selecting Do Not Beep After Good Decode, the beeper still operates during parameter menu scanning and to indicate error conditions.

*Beep After Good Decode (Enable) (01h)

Do Not Beep After Good Decode (Disable) (00h)

Page 48

4-6

DS9208-1D Product Reference Guide

Beeper Tone Parameter # 91h To select a decode beep frequency (tone), scan one of the following bar codes.

Off (03h)

Low Tone (02h)

*Medium Tone (01h)

High Tone (00h)

Medium to High Tone (2-tone) (04h)

Page 49

User Preferences & Miscellaneous Options

Beeper Volume Parameter # 8Ch To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume bar code.

Low Volume (02h)

Medium Volume (01h)

*High Volume (00h)

4-7

Page 50

4-8

DS9208-1D Product Reference Guide

Volume Adjustment Trigger Timeout Parameter # F0h 93h Use this parameter to set the length of time needed to hold the trigger to adjust the volume. The scanner changes volume and beeps with the new volume.

Volume Adjustment Trigger Timeout 3 sec (1Eh)

*Volume Adjustment Trigger Timeout 5 sec (32h)

Volume Adjustment Trigger Timeout 7 sec (46h)

Page 51

User Preferences & Miscellaneous Options

Beeper Duration Parameter # F1h 74h To select the duration for the beeper, scan one of the following bar codes.

Short (00h)

* Medium (01h)

Long (02h)

Suppress Power-up Beeps Parameter # F1h D1h Select whether or not to suppress the digital scanner’s power-up beeps.

* Do Not Suppress Power-up Beeps (00h)

Suppress Power-up Beeps (01h)

4-9

Page 52

4 - 10 DS9208-1D Product Reference Guide

Low Power Mode Parameter # 80h This parameter determines whether or not the digital scanner enters low power mode after a decode attempt. If disabled, power remains on after each decode attempt.

*Disable Low Power Mode (00h)

Enable Low Power Mode (01h)