Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 35

DS9208-1D Digital Scanner Product Reference Guide: Maintenance & Technical Specifications

Pages 35 to 42 of 276, from DS9208-1D Digital Scanner Product Reference Guide

The original document is the PDF (6.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Motorola DS-9208

Page 35

CHAPTER 3 MAINTENANCE & TECHNICAL SPECIFICATIONS Introduction This chapter provides suggested digital scanner maintenance, troubleshooting, technical specifications, and signal descriptions (pinouts).

Maintenance Cleaning the scan window is the only maintenance required. A dirty window can affect scanning accuracy.

• Do not allow abrasive material to touch the window. • Remove any dirt particles with a damp cloth. • Wipe the window using a dust-free soft cloth moistened with isopropyl alcohol-based cleaner. Do not let liquid pool around the window or any other area on the scanner.

• Do not spray water or other cleaning liquids directly into the window.

Page 36

3-2

DS9208-1D Product Reference Guide

Troubleshooting Table 3-1 Troubleshooting

Problem The aiming dot does not appear when pressing the trigger.

Possible Causes

Possible Solutions

No power to the digital scanner.

If the configuration requires a power supply, re-connect the power supply.

Incorrect host interface cable is used.

Connect the correct host interface cable.

Interface/power cables are loose.

Re-connect cables.

Digital scanner is disabled.

For IBM 468x and USB IBM hand-held, IBM table top, and OPOS modes, enable the digital scanner via the host interface. Otherwise, see the technical person in charge of scanning.

If using RS-232 Nixdorf B mode, CTS is not asserted.

Assert CTS line.

Aiming dot is disabled.

Enable the aiming dot. See Trigger Aiming Pattern on page 4-14.

Digital scanner emits short low/short medium/short high beep sequence (power-up beep sequence) more than once.

The USB bus may put the digital scanner in a state where power to the scanner is cycled on and off more than once.

Normal during host reset.

Digital scanner emits aiming dot, but does not decode the bar code.

Digital scanner is not programmed for that bar code type.

Program the digital scanner to read that type of bar code. See Chapter 9, Symbologies.

Bar code symbol is unreadable.

Scan test symbols of the same bar code type to determine if the bar code is defaced.

The aiming dot is not centered on the symbol.

Center the aiming dot on the symbol. See Aiming in Momentary Trigger Mode on page 2-7.

Picklist mode is preventing the digital scanner from decoding all bar codes in the field of view.

Disable Picklist mode. See Picklist Mode on page 4-21.

Page 37

Maintenance & Technical Specifications

3-3

Table 3-1 Troubleshooting (Continued)

Problem

Possible Causes

Possible Solutions

Digital scanner decodes bar code, but does not transmit the data to the host.

Digital scanner is not programmed for the correct host type.

Scan the appropriate host type programming bar code. See the chapter corresponding to the host type.

Interface cable is loose.

Re-connect the cable.

If the digital scanner emits 4 long low beeps, a transmission error occurred.

Set the scanner's communication parameters to match the host's setting.

If the digital scanner emits 5 low beeps, a conversion or format error occurred.

Configure the digital scanner's conversion parameters properly.

If the digital scanner emits low/high/low beeps, it detected an invalid ADF rule.

Program the correct ADF rules. Refer to the Advanced Data Formatting Programmer Guide.

If the digital scanner emits high/low beeps, the scanner is buffering Code 39 data.

Normal scanning a Code 39 bar code and the Code 39 Buffering option is enabled.

Digital scanner is not programmed to work with the host.

Scan the appropriate host type programming bar code.

Host displays scanned data incorrectly.

For RS-232, set the digital scanner's communication parameters to match the host's settings. For a Keyboard Wedge configuration, program the system for the correct keyboard type, and turn off the CAPS LOCK key. Program the proper editing options (e.g., UPC-E to UPC-A Conversion). Digital scanner emits low/low/low/extra low beeps when not in use.

RS-232 receive error.

Normal during host reset. Otherwise, set the digital scanner's RS-232 parity to match the host setting.

Digital scanner emits low/high beeps during programming.

Input error or Cancel bar code was scanned.

Scan the correct numeric bar codes within range for the parameter programmed.

Digital scanner emits low/high/low/high beeps during programming.

Out of ADF parameter storage space.

Erase all rules and re-program with shorter rules.

Page 38

3-4

DS9208-1D Product Reference Guide

Table 3-1 Troubleshooting (Continued)

Problem

Possible Causes

Possible Solutions

Digital scanner emits low/high/low beeps.

Clearing Code 39 buffer.

Normal when scanning the Code 39 Buffering Clear Buffer bar code or upon attempt to transmit an empty Code 39 buffer.

Digital scanner emits a power-up beep after changing USB host type.

The USB bus re-established power to the digital scanner.

Normal when changing USB host type.

Digital scanner emits one high beep when not in use.

In RS-232 mode, a <BEL> character was received and Beep on <BEL> option is enabled.

Normal when Beep on <BEL> is enabled and the digital scanner is in RS-232 mode.

NOTE

If after performing these checks the digital scanner still experiences problems, contact the distributor or Motorola Solutions support. See page xvi for contact information.

Report Software Version Bar Code When contacting Motorola Solutions support, a support representative may ask you to scan the bar code below to determine the version of software installed in the digital scanner.

Report Software Version

Page 39

Maintenance & Technical Specifications

3-5

Technical Specifications Table 3-2 Technical Specifications

Item

Description

Physical Characteristics Dimensions

5.512 in H x 3.232 in W x 3.150 in D 14.0 cm H x 8.21 cm W x 8.0 cm D

Weight

9.5 oz (269.3 g)

Voltage and Current

Idle: 5 +/-10% VDC @ 150 ma average Scanning: 5 +/-10% VDC @ 230 ma average

Performance Characteristics Light Source

Aiming dot: 625 nm LED Illumination: 630 nm LEDs

Imager Field of View (Horizontal x Vertical)

46º H x 29.5º V

Roll Pitch Yaw

360º +/- 65º +/- 60º

Swipe Speed

Up to 90 in (2.3 m) per second

Symbology Decode Capability 1D

UPC/EAN (UPC-A/UPC-E/UPC-E1/EAN-8/EAN-13/JAN-8/JAN-13 plus supplementals, ISBN (Bookland), ISSN, Coupon Code), Code 39 (Standard, Full ASCII, Trioptic, Code 32 (Italian Pharmacode)), Code 128 (Standard, Full ASCII, UCC/EAN-128, ISBT-128 Concatenated), Code 93, Codabar/NW7, 2 of 5 (Interleaved 2 of 5, Discrete 2 of 5, IATA, Chinese 2 of 5, Matrix 2 of 5, Code 11), MSI Plessey, GS1 DataBar (Omnidirectional, Truncated, Stacked, Stacked Omnidirectional, Limited, Expanded, Expanded Stacked)

Minimum Resolution

Code 39 – 4 mil, UPC – 7.8 mil (60%)

Typical Working Distance

See Decode Ranges on page 2-8.

Interfaces Supported

USB, RS-232, RS-485 (IBM 46xx protocols), keyboard wedge

User Environment Operating Temperature

32º F to 104º F (0º C to 40º C)

Humidity

5% to 85% RH, non-condensing

Drop Specifications

Withstands multiple 5 ft. (1.5 m) drops to concrete

Sealing

IP50

Page 40

3-6

DS9208-1D Product Reference Guide

Table 3-2 Technical Specifications (Continued)

Item Ambient Light Immunity

Description Immune to natural and artificial ambient light (i.e., sunlight, incandescent, fluorescent, mercury vapor, sodium vapor)

Options Electronic Article Surveillance (EAS)

Compatible with Checkpoint EAS deactivation systems

Mounting Options

Wall mount bracket, locking mount bracket

Page 41

Maintenance & Technical Specifications

Digital Scanner Signal Descriptions

Pin 10

Pin 1 Interface cable modular connector Figure 3-1 Digital Scanner Cable Pinouts

The signal descriptions in Table 3-3 apply to the connectors on the DS9208 digital scanner and are for reference only. Table 3-3

Pin

DS9208 Digital Scanner Signal Pin-outs Keyboard Wedge

IBM

RS-232

USB

1

Reserved

Reserved

Reserved

Jump to Pin 6

2

Power

Power

Power

Power

3

Ground

Ground

Ground

Ground

4

IBM_A(+)

TxD

KeyClock

Reserved

5

Reserved

RxD

TermData

D+

6

IBM_B(-)

RTS

KeyData

Jump to Pin 1

7

Reserved

CTS

TermClock

D-

8

Reserved

Reserved

Reserved

Reserved

9

Reserved

Reserved

Reserved

Reserved

10

Reserved

Reserved

Reserved

Reserved

3-7

Page 42

3-8

DS9208-1D Product Reference Guide