The text of a manual · part 11 of 35
DS9208-1D Digital Scanner Product Reference Guide: USB Interface, pages 73 to 82
Pages 73 to 82 of 276, from DS9208-1D Digital Scanner Product Reference Guide
The original document is the PDF (6.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Motorola DS-9208
Page 73
CHAPTER 5 USB INTERFACE Introduction This chapter describes how to set up the digital scanner with a USB host. The digital scanner connects directly to a USB host, or a powered USB hub, which powers it. No additional power supply is required. Throughout the programming bar code menus, asterisks (*) indicate default values.
*Indicates Default
NOTE
*North American Standard USB Keyboard
Feature/Option
Most computer monitors allow scanning the bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces are not merging.
Page 74
5-2
DS9208-1D Product Reference Guide
Connecting a USB Interface
Interface Cable
USB Connector
Figure 5-1 USB Connection
The digital scanner connects with USB-capable hosts including:
• Desktop PCs and notebooks • Apple™ iMac, G4, iBooks (North America only) • IBM SurePOS terminals
• Sun, IBM, and other network computers that support more than one keyboard. The following operating systems support the digital scanner through USB:
• Windows® 98, 2000, ME, XP • MacOS 8.5 and higher • IBM 4690 OS. The digital scanner also interfaces with other USB hosts which support USB Human Interface Devices (HID). To set up the digital scanner: NOTE
Interface cables vary depending on configuration. The connectors illustrated in Figure 5-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the digital scanner are the same. For digital scanners with the optional RFID module, connection requires a power supply.
1.
Connect the modular connector of the USB interface cable to the cable interface port on the digital scanner (see Installing the Interface Cable on page 1-3).
2.
Plug the series A connector in the USB host or hub, or plug the Plus Power connector in an available port of the IBM SurePOS terminal.
3.
Select the USB device type by scanning the appropriate bar code from USB Device Type on page 5-4.
Page 75
USB Interface
5-3
4.
On first installation when using Windows, the software prompts to select or install the Human Interface Device driver. To install this driver, provided by Windows, click Next through all the choices and click Finished on the last choice. The digital scanner powers up during this installation.
5.
To modify any other parameter options, scan the appropriate bar codes in this chapter.
If problems occur with the system, see Troubleshooting on page 3-2.
USB Parameter Defaults Table 5-1 lists the defaults for USB host parameters. To change any option, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 5-4. NOTE
See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies, and miscellaneous default parameters.
Table 5-1 USB Interface Parameter Defaults
Parameter
Default
Page Number
USB Host Parameters USB Device Type
HID Keyboard Emulation
5-4
Symbol Native API (SNAPI) Status Handshaking
Enable
5-5
USB Country Keyboard Types (Country Codes)
North American
5-6
USB Keystroke Delay
No Delay
5-8
Simulated Caps Lock
Disable
5-9
USB CAPS Lock Override
Disable
5-9
USB Ignore Unknown Characters
Enable
5-10
USB Convert Unknown to Code 39
Disable
5-10
USB Ignore Beep Directive
Honor
5-11
USB Ignore Type Directive
Honor
5-11
Emulate Keypad
Disable
5-12
Emulate Keypad with Leading Zero
Disable
5-12
USB FN1 Substitution
Disable
5-13
Function Key Mapping
Disable
5-13
Convert Case
None
5-14
USB Static CDC
Enable
5-14
USB Polling Interval
8 msec
5-15
Quick Keypad Emulation
Disable
5-17
Fast HID Keyboard Emulation
Disable
5-17
IBM Specification Version
Original Specification
5-18
Page 76
5-4
DS9208-1D Product Reference Guide
USB Host Parameters USB Device Type Select the desired USB device type. NOTE
When changing USB Device Types, the digital scanner automatically resets and issues the standard startup beep sequences.
NOTE
Before selecting USB CDC Host, install the CDC INF file on the host to ensure the scanner does not stall during power up (due to a failure to enumerate USB). If the scanner stalls, to recover it: 1) Install the CDC INF file or 2) After power-up, hold the trigger for 10 seconds, which allows the scanner to power up using an alternate USB configuration. Upon power-up, scan another USB Device Type.
*HID Keyboard Emulation
IBM Table Top USB
IBM Hand-Held USB
USB OPOS Hand-Held
Page 77
USB Interface
USB Device Type (continued)
Simple COM Port Emulation
USB CDC Host
Symbol Native API (SNAPI)
Symbol Native API (SNAPI) Status Handshaking After selecting a SNAPI interface as the USB device type, select whether to enable or disable status handshaking.
*Enable SNAPI Status Handshaking
Disable SNAPI Status Handshaking
5-5
Page 78
5-6
DS9208-1D Product Reference Guide
USB Country Keyboard Types - Country Codes Scan the bar code corresponding to the keyboard type. This setting applies only to the USB HID Keyboard Emulation device. NOTE
When changing USB country keyboard types the digital scanner automatically resets and issues the standard startup beep sequences.
*North American Standard USB Keyboard
German Windows
French Windows
French Canadian Windows 95/98
French Canadian Windows 2000/XP
Page 79
USB Interface
USB Country Keyboard Types - Country Codes (continued)
French Belgian Windows
Spanish Windows
Italian Windows
Swedish Windows
UK English Windows
Japanese Windows (ASCII)
Portuguese-Brazilian Windows
5-7
Page 80
5-8
DS9208-1D Product Reference Guide
USB Keystroke Delay This parameter sets the delay, in milliseconds, between emulated keystrokes. Scan a bar code below to increase the delay when hosts require a slower transmission of data.
*No Delay
Medium Delay (20 msec)
Long Delay (40 msec)
Page 81
USB Interface
5-9
Simulated Caps Lock Enable this to invert upper and lower case characters on the bar code as if the Caps Lock state is enabled on the keyboard. This inversion occurs regardless of the keyboard’s Caps Lock state. Note that this only applies to alpha characters.
*Disable Simulated Caps Lock
Enable Simulated Caps Lock
USB CAPS Lock Override This option applies only to the HID Keyboard Emulation device. Enable this to preserve the case of the data regardless of the state of the Caps Lock key. This setting is always enabled for the Japanese, Windows (ASCII) keyboard type and can not be disabled.
Override Caps Lock Key (Enable)
*Do Not Override Caps Lock Key (Disable)
NOTE
If both Simulated Caps Lock and Caps Lock Override are enabled, Caps Lock Override takes precedence.
Page 82
5 - 10 DS9208-1D Product Reference Guide
USB Ignore Unknown Characters This option applies only to the HID Keyboard Emulation device and IBM device. Unknown characters are characters the host does not recognize. Select Send Bar Codes With Unknown Characters to send all bar code data except for unknown characters. The digital scanner issues no error beeps. Select Do Not Send Bar Codes With Unknown Characters, for IBM devices, to prevent sending bar codes containing at least one unknown character are to the host, or for HID Keyboard Emulation devices, this sends the bar code characters up to the unknown character. The digital scanner issues an error beep.
*Send Bar Codes with Unknown Characters (Transmit)
Do Not Send Bar Codes with Unknown Characters (Disable)
USB Convert Unknown to Code 39 This option applies only to the IBM hand-held, IBM tabletop, and OPOS devices. Scan a bar code below to enable or disable converting unknown bar code type data to Code 39.
*Disable Convert Unknown to Code 39