Page 63

User Preferences & Miscellaneous Options 4 - 21

Picklist Mode Parameter # F0h 92h Picklist mode enables the digital scanner to decode only the bar code targeted by the aiming dot. Select one of the following picklist modes for the digital scanner:

• Disabled - Picklist mode is always disabled. • Enabled in Trigger Mode - Picklist mode is enabled when the digital scanner is out of trigger mode and disabled when the digital scanner is in presentation mode.

• Enabled Always - Picklist mode is always enabled. NOTE

Picklist mode functions optimally when bar codes are vertically spaced a minimum of 15 mm edge to edge.

Disabled (00h)

*Enabled in Trigger Mode (01h)

Enabled Always (02h)

Page 64

4 - 22 DS9208-1D Product Reference Guide

Continuous Bar Code Read Parameter # F1h 89h Enable this to report every bar code while the trigger is pressed. NOTE

Motorola strongly recommends enabling Picklist Mode with this feature. Disabling Picklist Mode can cause accidental decodes when more than one bar code is in the imaging engine's field of view.

*Disable Continuous Bar Code Read (00h)

Enable Continuous Bar Code Read (01h)

Unique Bar Code Reporting Parameter # F1h D3h Enable this to report only unique bar codes while the trigger is pressed. This option only applies when Continuous Bar Code Read is enabled.

*Disable Continuous Bar Code Read Uniqueness (00h)

Enable Continuous Bar Code Read Uniqueness (01h)

Page 65

User Preferences & Miscellaneous Options 4 - 23

Decode Session Timeout Parameter # 88h This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds. To set a Decode Session Timeout, scan the bar code below. Next, scan two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired on time. Enter a leading zero for single digit numbers. For example, to set a Decode Session Timeout of 0.5 seconds, scan the bar code below, then scan the 0 and 5 bar codes. To correct an error or change the selection, scan Cancel on page D-2. NOTE

The Decode Session Timeout cannot be less than or equal to either Timeout Between Decodes, Same Symbol or Timeout Between Decodes, Different Symbols.

Decode Session Timeout

Timeout Between Decodes, Same Symbol Parameter # 89h Use this option in presentation mode and Continuous Bar Code Read to prevent the beeper from continuously beeping when a symbol is left in the digital scanner’s field of view. It is programmable in 0.1 second increments from 0.0 to 9.9 seconds. The default interval is 0.3 seconds. To select the timeout between decodes for the same symbol, scan the bar code below, then scan two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired interval, in 0.1 second increments. NOTE

The Timeout between Decodes, Same Symbol cannot be greater than or equal to the Decode Session Timeout.

Timeout Between Decodes, Same Symbol

Page 66

4 - 24 DS9208-1D Product Reference Guide

Timeout Between Decodes, Different Symbols Parameter # 90h Use this option in presentation mode and Continuous Bar Code Read to control the time the scanner is inactive between decoding different symbols. It is programmable in 0.1 second increments from 0.1 to 9.9 seconds. The default is 0.2 seconds. To select the timeout between decodes for different symbols, scan the bar code below, then scan two numeric bar codes from Appendix D, Numeric Bar Codes that correspond to the desired interval, in 0.1 second increments. NOTE

The Timeout between Decodes, Different Symbols cannot be greater than or equal to the Decode Session Timeout.

Timeout Between Decodes, Different Symbols

Fuzzy 1D Processing Parameter # F1h 02h This option is enabled by default to optimize decode performance on 1D bar codes, including damaged and poor quality symbols. Disable this only if you experience time delays when detecting a no decode.

*Enable Fuzzy 1D Processing (01h)

Disable Fuzzy 1D Processing (00h)

Page 67

User Preferences & Miscellaneous Options 4 - 25

Motion Tolerance (Hand-Held Trigger Modes Only) Parameter # F2h 5Ah Less Motion Tolerance provides optimal decoding performance on 1D bar codes. To increase motion tolerance and speed decoding when scanning a series of 1D bar codes in rapid progression, scan More Motion Tolerance.

*Less Motion Tolerance (00h)

More Motion Tolerance (01h)

Page 68

4 - 26 DS9208-1D Product Reference Guide

Miscellaneous Scanner Parameters Transmit Code ID Character Parameter # 2Dh A Code ID character identifies the code type of a scanned bar code. This is useful when decoding more than one code type. In addition to any single character prefix already selected, the Code ID character is inserted between the prefix and the decoded symbol. Select no Code ID character, a Symbol Code ID character, or an AIM Code ID character. For Code ID Characters, see Symbol Code Identifiers on page B-1 and AIM Code Identifiers on page B-2. NOTE

If you enable Symbol Code ID Character or AIM Code ID Character, and enable Transmit “No Read” Message on page 4-30, the digital scanner appends the code ID for Code 39 to the NR message.

Symbol Code ID Character (02h)

AIM Code ID Character (01h)

*None (00h)

Page 69

User Preferences & Miscellaneous Options 4 - 27

Prefix/Suffix Values Key Category Parameter # P = 63h, S1 = 62h, S2 = 64h Decimal Value Parameter # P = 69h, S1 = 68h, S2 = 6Ah You can append a prefix and/or one or two suffixes to scan data for use in data editing. To set a value for a prefix or suffix, scan a four-digit number (i.e., four bar codes from Appendix D, Numeric Bar Codes) that corresponds to that value. See Table E-1 on page E-1 for the four-digit codes. When using host commands to set the prefix or suffix, set the key category parameter to 1, then set the 3-digit decimal value. See Table E-1 on page E-1 for the four-digit codes. To correct an error or change a selection, scan Cancel on page D-2. NOTE

To use Prefix/Suffix values, first set the Scan Data Transmission Format on page 4-28.

Scan Prefix (07h)

Scan Suffix 1 (06h)

Scan Suffix 2 (08h)

Data Format Cancel

Page 70

4 - 28 DS9208-1D Product Reference Guide

Scan Data Transmission Format Parameter # EBh To set the scan data format, scan one of the following bar codes. NOTE

If using this parameter do not use ADF rules to set the prefix/suffix.

To set values for the prefix and/or suffix, see Prefix/Suffix Values on page 4-27.

*Data As Is (00h)

<DATA> <SUFFIX 1> (01h)

<DATA> <SUFFIX 2> (02h)

<DATA> <SUFFIX 1> <SUFFIX 2> (03h)

<PREFIX> <DATA > (04h)

Page 71

User Preferences & Miscellaneous Options 4 - 29

Scan Data Transmission Format (continued)

<PREFIX> <DATA> <SUFFIX 1> (05h)

<PREFIX> <DATA> <SUFFIX 2> (06h)

<PREFIX> <DATA> <SUFFIX 1> <SUFFIX 2> (07h)

FN1 Substitution Values Key Category Parameter # 67h Decimal Value Parameter # 6Dh The wedge and USB HID keyboard hosts support a FN1 Substitution feature. Enabling this substitutes any FN1 character (0x1b) in an EAN128 bar code with a value. This value defaults to 7013 (Enter key). When using host commands to set the FN1 substitution value, set the key category parameter to 1, then set the 3-digit keystroke value. See the ASCII character set table for the current host interface for the desired value. To select a FN1 substitution value via bar code menus: 1.

Scan the bar code below.

Set FN1 Substitution Value

2.

Locate the keystroke desired for FN1 substitution in the ASCII character set table in the appropriate host interface chapter. Enter the 4-digit ASCII value by scanning each digit in Appendix D, Numeric Bar Codes.

To correct an error or change the selection, scan Cancel on page D-2. See USB Keyboard FN 1 Substitution on page 5-13 to enable FN1 substitution for the USB HID keyboard.

Page 72

4 - 30 DS9208-1D Product Reference Guide

Transmit “No Read” Message Parameter # 5Eh Scan a bar code below to select whether or not to transmit a No Read message. Enable this to transmit the characters NR when a successful decode does not occur before trigger release or the Decode Session Timeout expires. See Decode Session Timeout on page 4-23. Disable this to send nothing to the host if a symbol does not decode. NOTE

If you enable Transmit No Read, and also enable Symbol Code ID Character or AIM Code ID Character for Transmit Code ID Character on page 4-26, the digital scanner appends the code ID for Code 39 to the NR message.

Enable No Read (01h)

*Disable No Read (00h)