Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 18 of 21

Monarch DOS-based PATHFINDER Ultra System, pages 171 to 180

Pages 171 to 180 of 210

The original document is the PDF (4.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Monarch Ultra 6035

Page 171

426

Item not checked out. Call Technical Support.

427

Format name is invalid. Valid name is 1 - 8 characters inside quotes or "" for a printer-assigned name. If the error reappears, call Technical Support.

428

Batch name is invalid. If the error reappears, call Technical Support.

429

The field number appears more than once in a format.

431

The format file cannot be found.

433

The batch references a field number that does not exist in the format.

434

Internal software error caused by a downloaded task that is not executable. Turn off the printer. Wait two seconds and turn it back on. If the error persists, call Technical Support.

435

Internal software error caused by a downloaded task that already exists. Turn off the printer. Wait two seconds and turn it back on. If the error persists, call Technical Support.

Data Formatting Failures Formatting errors indicate that a field will print incorrectly. After you have checked the data stream and corrected the data, retransmit the format and batch. For errors 571-619, the batch will still print, but the field, font, bar code, or density may be incomplete, missing or contain incorrect data. 571

UPC or EAN bar code data length is invalid. The bar code data length in the batch does not fit the format.

573

Price field length is invalid. The price field length in the batch does not fit the format or the field contains blanks.

574

No CD scheme or room for CD. The CD scheme in the batch does not fit the format or the field contains blanks.

580

Out of memory. Try to reallocate memory. Resend the packet. If the error persists, call Technical Support.

Troubleshooting 12-9

Page 172

603

Internal software error caused by the batch not being held. Turn off the printer. Wait two seconds and turn it back on. If the error persists, call Technical Support.

611

Font, bar code or density is invalid. The font, bar code or density in the batch does not fit the format.

612

The data in this line of the batch is either missing or does not match the format.

613

Reference point off tag.

614

Portion of field off tag. There may be an invalid character in the packet. Make sure you did not enter O for ∅ .

615

Bar code width is greater than 16 inches or the number of keywords for your PDF 417 bar code exceeds 928. Decrease the density or shorten the amount of data to print the bar code.

616

Dot shifting failed. A bad dot falls on a bar code that cannot be shifted. Call Technical Support.

618

Magnification must be 1 to 7.

Machine Faults Errors 700 to 799 occur when there is a problem with the printer. 703

The printer sensed a calibration of different-sized black marks. Make sure the correct supply is loaded.

704

Printer has not sensed a supply mark within the specified number of inches or out of supplies. Check the supply tracking, supply marks, black mark sensor position, and supply roll for binding. If the error continues to appear, change the supply.

730

A memory allocation error occurred during initialization.

750

Printhead is overheated. Turn off the printer to let the printhead cool. If the error persists, call Technical Support.

12-10 Troubleshooting

Page 173

751

Printer did not sense a black mark when expected. The supply may be jammed. For errors 751-753, Check the supply tracking, supply marks, black mark sensor position, and supply roll for binding. If the error continues to appear, change the supply.

752

Printer sensed a mark in the wrong place.

753

Printer sensed a mark that is too long.

755

Printhead is open. Close the printhead before continuing. If the error persists, call Technical Support.

756

The printer is out of supplies. Load supplies.

757

Load supplies. The calibrated supply length differs by plus or minus .25 inches from the format.

758

Check supply. Either the supply is not seen or the on-demand sensor is broken. Check for a label jam. Clear the supply path or reload supplies. This error may occur if you remove a label too quickly in on-demand mode. The printer does not recalibrate after this error.

762

Low battery. Recharge the battery.

763

Waiting to dispense label. Press the trigger.

765

Printhead failure. You need a new printhead. Call Technical Support.

770

The print motor is not ready. Call Technical Support.

771

The format was not found. Recreate the format, and try again. If the problem continues, call Technical Support.

790

The printer is busy. Turn off the printer. Wait two seconds and turn it back on. Resend the packets. If the problem continues, call Technical Support.

791

The printer has an error pending. Turn off the printer. Wait two seconds and turn it back on. Resend the packets. If the problem continues, call Technical Support.

Troubleshooting 12-11

Page 174

792

The printer is not initialized. Call Technical Support.

793

The printer job queue is full. Turn off the printer. Wait two seconds and turn it back on. Resend the packets. If the problem continues, call Technical Support.

Errors numbered 900-999 are hard printer failures. Call Technical Support if you receive these messages.

12-12 Troubleshooting

Page 175

SAMPLE FORMATS

A

The following pages include several samples of different applications, such as item pricing, item identification and receiving/inventory. You can customize any of these formats to meet your needs.

Item Pricing The following sample, PRETZELS (2.0 long x 2.0 wide), contains two text fields, one bar code field, and one price field. The human readable characters under the bar code are automatically generated using a combo text field that copies the data entered from the bar code field. Use the following information to create the bar code field: Prompts

Bar Code Field 1

Bar Code

1. UPC-A

Field Class

1. Simple

Field Prompt

SCAN UPC#

Fixed Data

None

Row

80

Column

15

Density

1. 80

Bar Height

40

Field Rotation

1. Top of Supply

Edits

None

Sample Formats A-1

Page 176

Use the following information to create the text and combo text field for human readable characters: Prompts

Text Field 2

Combo Field 3

Field Class

1. Simple

2. Combo

Data Type

Alpha-numeric

N/A

Max. Length

10

12

Min. Length

1

1

Field Prompt

ENTER ITEM

N/A

Field Number

N/A

01

Start Position

N/A

01

Num. of Chars.

N/A

12

Fill Direction

N/A

3. Do not Fill

Fixed Data

None

None

Row

135

65

Column

35

15

Font

2. CG Trium 8pt 1001

2. CG Trium 8pt 1001

Height Mag.

1

1

Width Mag.

1

1

Justification

1. Left

1. Left

Field Rotation

1. Top of Supply

1. Top of Supply

Edits

None

None

A-2 Sample Formats

Page 177

Use the following information to create the price field: Prompts

Price Field 4

Field Class

2. Price Field

Max. Length

5 (including the $ and . point)

Min. Length

1

Field Prompt

ENTER PRICE

Fixed Data

None

Row

40

Column

35

Font

2. CG Trium 8pt 1001

Height Mag.

1

Width Mag.

1

Justification

1. Left

Field Rotation

1. Top of Supply

Sample Formats A-3

Page 178

The following sample, DETERGENT (2.0 long x 2.0 wide), contains two text fields, one bar code field, and one price field. To print the human readable characters, you must set the default UPC appearance from the configuration menu. Use the following information to create the bar code field: Prompts

Bar Code Field 1

Bar Code

1. UPC-A

Field Class

1. Simple

Field Prompt

SCAN UPC#

Fixed Data

None

Row

80

Column

25

Density

2. 120

Bar Height

45

Field Rotation

1. Top of Supply

Edits

None

A-4 Sample Formats

Page 179

Use the following information to create the text (item) and text (dept.) fields: Prompts

Text Field 2

Text Field 3

Field Class

1. Simple Field

1. Simple Field

Data Type

Alpha-numeric

Alpha-numeric

Max. Length

12

5

Min. Length

1

1

Field Prompt

ENTER ITEM

ENTER DEPT#

Fixed Data

None

None

Row

55

25

Column

50

15

Font

2. CG Trium 8pt 1001

2. CG Trium 8pt 1001

Height Mag.

1

1

Width Mag.

1

1

Justification

1. Left

1. Left

Field Rotation

1. Top of Supply

1. Top of Supply

Edits

None

None

Sample Formats A-5

Page 180

Use the following information to create the price field: Prompts

Price Field 4

Field Class

2. Price Field

Max. Length

5 (including the $ and . point)

Min. Length

1

Field Prompt

ENTER PRICE

Fixed Data

None

Row

25

Column

140

Font

2. CG Trium 8pt 1001

Height Mag.

1

Width Mag.

1

Justification

1. Left

Field Rotation

1. Top of Supply

A-6 Sample Formats