The text of a manual · part 17 of 21

Monarch DOS-based PATHFINDER Ultra System, pages 161 to 170

Pages 161 to 170 of 210

The original document is the PDF (4.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Monarch Ultra 6035

Page 161

Deleting a Format We will delete our SHOE-TAG format. - = Main Menu = 1. Design Formats 2. Print Labels 3. Configuration

1.

Press 1 to design your formats.

- = Design Menu = 1. Create New Format 2. Edit Old Format 3. Copy Format 4. Delete Format

2.

Press 4 to delete an existing format.

Select Format for Deletion _

3.

Select SHOE-TAG. Press e.

4.

Press Y.

5.

The format is deleted and you return to the Design menu.

- = Format Menu = 01 SHOE-TAG 02 SHOE-PRICE 03 AUTOPART 04 PRICE 05 LINE2 06 LINE 07 CONSTANT Delete Format: 01 SHOE-TAG Are you sure? Y/N _ L Format Deleted!

- = Design Menu = 1. Create New Format 2. Edit Old Format 3. Copy Format 4. Delete Format

Editing a Format 11-13

Page 162

11-14 Editing a Format

Page 163

TROUBLESHOOTING

12

This chapter explains how to reset the printer, call Technical Support, and gives explanations of your printer's errors. The errors are classified by type and are listed in order. Call Technical Support if you receive any error message not listed in this chapter. If you have trouble loading supplies or performing maintenance, refer to your Equipment Manual. Problem

Solution

Error:Field off tag MPCL Error #614 Redefine current field

The field you are defining has run off the tag. You must redefine it.

Warning: Possible Field off tag error. Do you wish to redefine current field? (Y)es / (N)o > _

The field you are defining may run off the tag. You can, but it is not necessary, to redefine the field. Press Y to redefine or N to continue. When you print, one or more fields may not print if they are off the supply.

No fields in fmt

You saved the format without entering any fields. Delete the format, and recreate it.

Warning: Low Battery Save changes and exit to Main Menu (Press any key)

Replace the current battery handle with a fully charged one. See your Equipment Manual for battery charging information.

Duplicate Name ReEnter _

Type a new format name and press e. You cannot have duplicate format names.

If you see the “Hot Key List”

Press e or b to return to the Main Menu.

Troubleshooting 12-1

Page 164

Problem

Solution

If you see the DOS prompt B:\

Type g and press e to start the application.

I2 of 5 bar codes do not scan.

Refer to the Equipment Manual for proper scanning techniques. Verify that the I2 of 5 bar code scan lengths specified in the printer configuration are even numbers of characters.

Troubleshooting Information If you experience problems using your printer, refer to this section.

If You Receive an Error Message Any time you receive a message that is not described in this manual, or the recommended action does not solve the problem, call Technical Support.

Calling Technical Support Technical support representatives are available Monday through Friday during regular business hours at 1-800-543-6650. Follow these steps before you call: 1.

Record any error messages that occurred.

2.

Try to recreate the problem, if you can.

3.

List any changes that have recently been made to the system. Try to record what you did when the problem occurred.

If these steps do not solve the problem, call Technical Support.

12-2 Troubleshooting

Page 165

Have the following information ready before you call: ♦

Monarch printer model

♦ support agreement, contract number, or invoice information

♦ customer number

♦ printer serial number

Data Errors Errors 001 to 499 are data errors. A data error indicates that incorrect data was received from the host, causing the printer to ignore the entire print job. After checking the packet and correcting the problem, transmit the print job again. The following is a list of data errors. These errors occur because data in the format, batch, check digit, font, or graphic packet is invalid.

Format Errors (1 - 99) Error Code

Description

001

Format ID number must be 1 to 99.

002

Name must be 1 to 8 characters inside quotes or a printer-assigned name ("").

003

Action must be A (add) or C (clear).

004

Supply length is invalid (maximum is 4").

005

Supply width is invalid (maximum is 2").

006

Storage device must be R (volatile RAM).

007

Unit of measure must be E (English).

010

Field ID number is outside the range 0 to 999.

011

Field length exceeds 2710.

012

Row field position is greater than the maximum stock dimension.

013

Column field position is greater than the maximum stock dimension.

Troubleshooting 12-3

Page 166

014

Font style is invalid. See Chapter 5, "Defining Text Fields," for more information.

015

Character rotation must be 0 (0 degrees), 1 (90 degrees), 2 (180 degrees), or 3 (270 degrees). See Chapter 5, “Defining Text Fields," for information.

016

Field rotation must be 0 (0 degrees), 1 (90 degrees), 2 (180 degrees), or 3 (270 degrees). See Chapter 5, “Defining Text Fields" for information.

017

Field restriction must be V (variable) or F (fixed).

018

Code page selection defined in the field must be 1 (ASCII).

020

Vertical magnification must be 1 to 7.

021

Horizontal magnification must be 1 to 7.

022

Color must be Black Opaque, White Opaque, Black Transparent, or White Transparent. See Chapter 5, "Defining Text Fields," for more information.

023

Intercharacter gap must be 0 to 9 dots.

024

Field justification must be B (balanced), L (left), or R (right). See Chapter 5, "Defining Text Fields," for more information.

025

Data length is too long.

030

Bar code height must be at least 1 or is not within the supply dimensions.

031

Human readable option must be 1 no CD or NS 5 NS at bottom, no CD 6 CD at bottom, no NS 7 CD and NS at bottom 8 no text

032

Bar code type is invalid. See Chapter 6, “Defining Bar Code Fields," for valid options.

12-4 Troubleshooting

Page 167

033

Bar code density is invalid. See Chapter 6, "Defining Bar Code Fields," for the bar code density values.

040

Line thickness must be 1 to 10.

041

Line angle must be 0, 90, 180, or 270.

042

End row is invalid. Line segment end row is defined outside of printable area. See Chapter 8, “Defining Line Fields,” for more information.

043

End column is invalid. Line segment end column is defined outside of printable area. See Chapter 8, “Defining Line Fields,” for more information.

044

Dot pattern for line or box must be "".

045

Line length is defined beyond the maximum length of 3.72". See Chapter 8, "Defining Line Fields," for valid lengths.

046

Line type must be S (segment) or V (vector).

051

Imaging mode in the graphic header must be 0.

Batch Errors (100 - 199) 101

The format referenced by batch is not in memory.

102

Print quantity is outside the range 0 to 25.

104

Batch mode must be N (new) or U (update).

105

Batch separator in a batch control field must be 0 (Off).

106

Print multiple is not 1.

108

Multiple part supply is outside the range 1 to 5.

Option Errors (200 - 249) 200

Option number must be 1, 4, 31, or 50.

201

Copy length is outside the range 0 to 255.

Troubleshooting 12-5

Page 168

202

Copy start position must be 1 to 255.

203

Destination start position must be 1 to 255.

204

Source field must be 0 to 999.

205

Copy type must be 1 (copy after rules) or 2 (copy before rules).

211

Narrow element value is less than 1 or greater than 99. Correct the value and resend the format to the printer.

212

Wide element value is less than 1 or greater than 99. Correct the value and resend the format to the printer.

214

Truncation code must be S (standard) or T (truncated bar code).

215

Aspect code must be C (columns) or R (rows).

216

Option definition must be S (set) or T (template).

217

Input device must be D (Default), H (Host), K (Keyboard), N (None), or S (Scanner).

220

Check digit selection must be G to generate check digit.

221

Primary or secondary price format is outside the range 1 to 15.

222

Data type restriction is outside the range of 1 to 6.

223

Option is not valid for the field.

Online Configuration Errors (250 - 299) 251

Power up mode must be 0 (online).

252

Language selection must be 0 (English).

253

Batch separator code in a supply setup packet must be 0 (off).

254

Slash zero selection must be 0 (standard zero).

255

Supply type must be 0 (black mark) or 1 (die cut).

256

Ribbon selection must be 0 (direct) or 1 (transfer).

257

Feed mode must be 0 (continuous) or 1 (on-demand).

12-6 Troubleshooting

Page 169

258

Supply position is outside the range.

259

Contrast adjustment must be -28 to 11.

260

Print adjustment must be -99 to 99.

261

Margin adjustment must be -99 to 99.

262

Speed adjustment must be 0 (1.0 IPS).

263

Primary monetary symbol is invalid.

264

Secondary symbol selection must be 0 (none) or 1 (print secondary sign).

265

Monetary decimal places must be 0 to 3.

272

Internal code page selection must be 1 (ASCII).

273

Cut adjustment must be -99 to 99 dots.

282

RS232 Trailer string is too long. Use a maximum of 3 characters.

283

ENQ Trailer string is too long. Use a maximum of 3 characters.

284

The buffer type must be T (Transmit), R (Receive), I (Image), F (Format), or D (Downloadable Fonts).

285

The storage device type in the memory configuration packet must be R (volatile RAM).

286

The buffer size is invalid.

287

The printhead width must be 1.83 inches.

288

The battery voltage must be 1 (12-volt battery).

289

The printer address specified in the communication settings packet must use exactly six characters.

Check Digit Errors (300 - 324) 310

Check digit scheme number must be 1 to 10.

311

Modulus must be 2 to 11.

Troubleshooting 12-7

Page 170

314

Check digit algorithm must be D (sum of digits) or P (sum of products).

General Packet Errors (400 - 435) 400

The character immediately following { is invalid.

401

Internal data error. Call Technical Support.

402

Field separator is not in the expected location.

403

Field separator was not found.

404

The number or string that is currently being processed is too long.

405

Too many fields exist in the format. You cannot have more than 50 fields in the format. Lines and constant text fields count as fields.

406

Packet is incomplete, attempted to delete or overwrite a format used by the current batch, or attempted to load a graphic while the printer was busy.

407

Parser timed out- no data. Resend packet to the printer.

408

No data. Resend packet to the printer.

409

The printer memory is full. Delete unnecessary formats from memory.

415

The buffer size you defined exceeds the total available in your machine.

420

Internal software error relating to list sync. Call Technical Support.

421

Internal software error relating to location name. Call Technical Support.

422

Internal software error relating to duplicate name. Call Technical Support.

423

Internal mailbox error. Call Technical Support.

424

Item in use. Call Technical Support.

425

Item already checked out. Call Technical Support.

12-8 Troubleshooting