Page 161
Deleting a Format We will delete our SHOE-TAG format. - = Main Menu = 1. Design Formats 2. Print Labels 3. Configuration
1.
Press 1 to design your formats.
- = Design Menu = 1. Create New Format 2. Edit Old Format 3. Copy Format 4. Delete Format
2.
Press 4 to delete an existing format.
Select Format for Deletion _
3.
Select SHOE-TAG. Press e.
4.
Press Y.
5.
The format is deleted and you return to the Design menu.
- = Format Menu = 01 SHOE-TAG 02 SHOE-PRICE 03 AUTOPART 04 PRICE 05 LINE2 06 LINE 07 CONSTANT Delete Format: 01 SHOE-TAG Are you sure? Y/N _ L Format Deleted!
- = Design Menu = 1. Create New Format 2. Edit Old Format 3. Copy Format 4. Delete Format
Editing a Format 11-13
Page 162
11-14 Editing a Format
Page 163
TROUBLESHOOTING
12
This chapter explains how to reset the printer, call Technical Support, and gives explanations of your printer's errors. The errors are classified by type and are listed in order. Call Technical Support if you receive any error message not listed in this chapter. If you have trouble loading supplies or performing maintenance, refer to your Equipment Manual. Problem
Solution
Error:Field off tag MPCL Error #614 Redefine current field
The field you are defining has run off the tag. You must redefine it.
Warning: Possible Field off tag error. Do you wish to redefine current field? (Y)es / (N)o > _
The field you are defining may run off the tag. You can, but it is not necessary, to redefine the field. Press Y to redefine or N to continue. When you print, one or more fields may not print if they are off the supply.
No fields in fmt
You saved the format without entering any fields. Delete the format, and recreate it.
Warning: Low Battery Save changes and exit to Main Menu (Press any key)
Replace the current battery handle with a fully charged one. See your Equipment Manual for battery charging information.
Duplicate Name ReEnter _
Type a new format name and press e. You cannot have duplicate format names.
If you see the “Hot Key List”
Press e or b to return to the Main Menu.
Troubleshooting 12-1
Page 164
Problem
Solution
If you see the DOS prompt B:\
Type g and press e to start the application.
I2 of 5 bar codes do not scan.
Refer to the Equipment Manual for proper scanning techniques. Verify that the I2 of 5 bar code scan lengths specified in the printer configuration are even numbers of characters.
Troubleshooting Information If you experience problems using your printer, refer to this section.
If You Receive an Error Message Any time you receive a message that is not described in this manual, or the recommended action does not solve the problem, call Technical Support.
Calling Technical Support Technical support representatives are available Monday through Friday during regular business hours at 1-800-543-6650. Follow these steps before you call: 1.
Record any error messages that occurred.
2.
Try to recreate the problem, if you can.
3.
List any changes that have recently been made to the system. Try to record what you did when the problem occurred.
If these steps do not solve the problem, call Technical Support.
12-2 Troubleshooting
Page 165
Have the following information ready before you call: ♦
Monarch printer model
♦ support agreement, contract number, or invoice information
♦ customer number
♦ printer serial number
Data Errors Errors 001 to 499 are data errors. A data error indicates that incorrect data was received from the host, causing the printer to ignore the entire print job. After checking the packet and correcting the problem, transmit the print job again. The following is a list of data errors. These errors occur because data in the format, batch, check digit, font, or graphic packet is invalid.
Format Errors (1 - 99) Error Code
Description
001
Format ID number must be 1 to 99.
002
Name must be 1 to 8 characters inside quotes or a printer-assigned name ("").
003
Action must be A (add) or C (clear).
004
Supply length is invalid (maximum is 4").
005
Supply width is invalid (maximum is 2").
006
Storage device must be R (volatile RAM).
007
Unit of measure must be E (English).
010
Field ID number is outside the range 0 to 999.
011
Field length exceeds 2710.
012
Row field position is greater than the maximum stock dimension.
013
Column field position is greater than the maximum stock dimension.
Troubleshooting 12-3
Page 166
014
Font style is invalid. See Chapter 5, "Defining Text Fields," for more information.
015
Character rotation must be 0 (0 degrees), 1 (90 degrees), 2 (180 degrees), or 3 (270 degrees). See Chapter 5, “Defining Text Fields," for information.
016
Field rotation must be 0 (0 degrees), 1 (90 degrees), 2 (180 degrees), or 3 (270 degrees). See Chapter 5, “Defining Text Fields" for information.
017
Field restriction must be V (variable) or F (fixed).
018
Code page selection defined in the field must be 1 (ASCII).
020
Vertical magnification must be 1 to 7.
021
Horizontal magnification must be 1 to 7.
022
Color must be Black Opaque, White Opaque, Black Transparent, or White Transparent. See Chapter 5, "Defining Text Fields," for more information.
023
Intercharacter gap must be 0 to 9 dots.
024
Field justification must be B (balanced), L (left), or R (right). See Chapter 5, "Defining Text Fields," for more information.
025
Data length is too long.
030
Bar code height must be at least 1 or is not within the supply dimensions.
031
Human readable option must be 1 no CD or NS 5 NS at bottom, no CD 6 CD at bottom, no NS 7 CD and NS at bottom 8 no text
032
Bar code type is invalid. See Chapter 6, “Defining Bar Code Fields," for valid options.
12-4 Troubleshooting
Page 167
033
Bar code density is invalid. See Chapter 6, "Defining Bar Code Fields," for the bar code density values.
040
Line thickness must be 1 to 10.
041
Line angle must be 0, 90, 180, or 270.
042
End row is invalid. Line segment end row is defined outside of printable area. See Chapter 8, “Defining Line Fields,” for more information.
043
End column is invalid. Line segment end column is defined outside of printable area. See Chapter 8, “Defining Line Fields,” for more information.
044
Dot pattern for line or box must be "".
045
Line length is defined beyond the maximum length of 3.72". See Chapter 8, "Defining Line Fields," for valid lengths.
046
Line type must be S (segment) or V (vector).
051
Imaging mode in the graphic header must be 0.
Batch Errors (100 - 199) 101
The format referenced by batch is not in memory.
102
Print quantity is outside the range 0 to 25.
104
Batch mode must be N (new) or U (update).
105
Batch separator in a batch control field must be 0 (Off).
106
Print multiple is not 1.
108
Multiple part supply is outside the range 1 to 5.
Option Errors (200 - 249) 200
Option number must be 1, 4, 31, or 50.
201
Copy length is outside the range 0 to 255.
Troubleshooting 12-5
Page 168
202
Copy start position must be 1 to 255.
203
Destination start position must be 1 to 255.
204
Source field must be 0 to 999.
205
Copy type must be 1 (copy after rules) or 2 (copy before rules).
211
Narrow element value is less than 1 or greater than 99. Correct the value and resend the format to the printer.
212
Wide element value is less than 1 or greater than 99. Correct the value and resend the format to the printer.
214
Truncation code must be S (standard) or T (truncated bar code).
215
Aspect code must be C (columns) or R (rows).
216
Option definition must be S (set) or T (template).
217
Input device must be D (Default), H (Host), K (Keyboard), N (None), or S (Scanner).
220
Check digit selection must be G to generate check digit.
221
Primary or secondary price format is outside the range 1 to 15.
222
Data type restriction is outside the range of 1 to 6.
223
Option is not valid for the field.
Online Configuration Errors (250 - 299) 251
Power up mode must be 0 (online).
252
Language selection must be 0 (English).
253
Batch separator code in a supply setup packet must be 0 (off).
254
Slash zero selection must be 0 (standard zero).
255
Supply type must be 0 (black mark) or 1 (die cut).
256
Ribbon selection must be 0 (direct) or 1 (transfer).
257
Feed mode must be 0 (continuous) or 1 (on-demand).
12-6 Troubleshooting
Page 169
258
Supply position is outside the range.
259
Contrast adjustment must be -28 to 11.
260
Print adjustment must be -99 to 99.
261
Margin adjustment must be -99 to 99.
262
Speed adjustment must be 0 (1.0 IPS).
263
Primary monetary symbol is invalid.
264
Secondary symbol selection must be 0 (none) or 1 (print secondary sign).
265
Monetary decimal places must be 0 to 3.
272
Internal code page selection must be 1 (ASCII).
273
Cut adjustment must be -99 to 99 dots.
282
RS232 Trailer string is too long. Use a maximum of 3 characters.
283
ENQ Trailer string is too long. Use a maximum of 3 characters.
284
The buffer type must be T (Transmit), R (Receive), I (Image), F (Format), or D (Downloadable Fonts).
285
The storage device type in the memory configuration packet must be R (volatile RAM).
286
The buffer size is invalid.
287
The printhead width must be 1.83 inches.
288
The battery voltage must be 1 (12-volt battery).
289
The printer address specified in the communication settings packet must use exactly six characters.
Check Digit Errors (300 - 324) 310
Check digit scheme number must be 1 to 10.
311
Modulus must be 2 to 11.
Troubleshooting 12-7
Page 170
314
Check digit algorithm must be D (sum of digits) or P (sum of products).
General Packet Errors (400 - 435) 400
The character immediately following { is invalid.
401
Internal data error. Call Technical Support.
402
Field separator is not in the expected location.
403
Field separator was not found.
404
The number or string that is currently being processed is too long.
405
Too many fields exist in the format. You cannot have more than 50 fields in the format. Lines and constant text fields count as fields.
406
Packet is incomplete, attempted to delete or overwrite a format used by the current batch, or attempted to load a graphic while the printer was busy.
407
Parser timed out- no data. Resend packet to the printer.
408
No data. Resend packet to the printer.
409
The printer memory is full. Delete unnecessary formats from memory.
415
The buffer size you defined exceeds the total available in your machine.
420
Internal software error relating to list sync. Call Technical Support.
421
Internal software error relating to location name. Call Technical Support.
422
Internal software error relating to duplicate name. Call Technical Support.
423
Internal mailbox error. Call Technical Support.
424
Item in use. Call Technical Support.
425
Item already checked out. Call Technical Support.
12-8 Troubleshooting