Defining the System Setup Packet Use the system setup packet (A) to select the power up mode, display language, print separators between batches, print a "slashed zero," and select the symbol set. Syntax A1. A
{I,A,powup_mode,language,sep_on,slash_zero, symbol_set p} System Setup Packet
A2. powup_mode Online Mode. Must use 0. A3. language
Display Language. Must use 0.
A4. sep_on
Batch Separators. Options: 0 Does not print a separator (default for all printers). 1 Prints a separator.
A5. slash_zero
Slash Zero. Options: 0 Print a standard zero (default for all printers). 1 Print a zero with a slash through it.
A6. symbol_set
Symbol Set. Options: 0 Internal/ Monarch (default for all printers) 1 ANSI 2 Code Page 437 3 Code Page 850
Example
{I,A,0,0,1,1,0 p }
Powers up the printer in the online mode, displays prompts in English, prints a separator after each batch, prints zeros with slashes through them, and uses the internal symbol set.
Configuring the Printer 3-9
Page 32
Defining the Supply Setup Packet Use the supply setup packet (B) to select supply type, ribbon, feed mode, supply position, and cut position. Syntax
{I,B,supply_type,ribbon_on,feed_mode, supply_posn,cut_posn p}
B1. B
Supply Setup Packet
B2. supply_type
Supply Type. Options: 0 Black mark stock 1 Die Cut/aperture stock (default for all printers) 2 Non-indexed stock To use black mark supplies, send this packet {I,B,0,,,,, p}. Turn off the printer. Turn the printer on while holding the FEED button. Release when the supply starts to advance. After the printer prints a test label, press the FEED button again to exit Data Dump mode. Turn off the printer and then, turn it back on. The printer is ready for black mark operation.
B3. ribbon_on
Ribbon. Options: 0 Ribbon not installed (9414 default) 1 Ribbon installed (9412/9413 default) NOTE: The 9414 printer does not support a ribbon.
B4. feed_mode
Feed Mode. Options: 0 Continuous operation (default for all printers) 1 On-demand mode For the 9412/9413 printers, you must have the on-demand sensor installed to use on-demand mode. Also, the feed mode is determined by the presence of the on-demand sensor, not from this parameter. If the on-demand sensor is open, you are using on-demand mode. If the on-demand sensor is closed, you are using continuous mode. There is a switch on the 9414 printer for on-demand mode. Refer to your Equipment Manual for more information.
B5. supply_posn -300 to 300 in 1/203 inch. 0 is the default for all printers. Adjusts the machine to print at the vertical 0,0 point on the supply. This adjustment accounts for mechanical tolerances from machine to machine. The supply position adjustment only needs to be made on the initial machine setup. You can’t change the supply position while the printer is active. Changing the supply position will affect the print position.
3-10 Configuring the Printer
Page 33
B6. cut_posn
Example
-99 to 99 in 1/203 inch. Use 0 for these printers.
{I,B,0,0,1,10,0 p }
Indicates black mark and thermal direct stock has been loaded, causes the printer to operate in on-demand mode and feeds the supply approximately .05 inches up before printing the format on each label (10/203 inches).
Defining the Print Control Packet Use the print control packet (C) to set the contrast, print, and margin adjustment, print speed, and printhead width. Syntax
{I,C,contrast,print_adj,margin_adjust, speed_adj,ph_width p }
C1. C
Print Control Packet
C2. contrast
-390 to 156. 0 is the default for all printers.
C3. print_adj
-99 to 99 in 1/203 inch. 0 is the default for all printers. Adjusts where data prints vertically on the supply. Increase the print position to move print up, decrease to move print down.
C4. margin_adj
-99 to 99 in 1/203 inch. 0 is the default for all printers. Adjusts where data prints horizontally on the supply. Increase the margin position to move print to the right, decrease to move print to the left. Margin and print position are format adjustments. They will not affect the supply position.
C5. speed_adj
Print speed. Use 0 for these printers.
C6. ph_width
Width of the printhead in dots. Use 0 for these printers.
Example
{I,C,0,-20,-10,0,0 p }
Uses the default contrast, moves print 0.1 inch closer to the bottom of the supply (20/203 inches) and .05 inch to the left on the supply (10/203 inches), prints at two inches per second, and uses the default printhead width.
Configuring the Printer 3-11
Page 34
Defining the Monetary Formatting Packet The monetary formatting packet (D) selects the monetary symbols to print for a price field. Use the monetary formatting packet to select primary and secondary monetary symbols, and designate the number of digits to appear at the right of a decimal. Syntax
{I,D,cur_sym,secondary,decimals p }
D1. D
Monetary Formatting Packet
D2. cur_sym
Currency Symbol. Options: 0 No symbol 1 USA ($, Dollar- default for all printers) 2 UK (£, Pound) 3 Japan (¥, Yen) 4 Germany (1, Deutsche Mark) 5 France (F, Franc) 6 Spain (P, Peseta) 7 Italy (L., Lira) 8 Sweden (Kr, Krona) 9 Finland (2, Markka) 10 Austria (6, Shilling) 11 India (Rs, Rupee) 12 Russian (3, Ruble) 13 Korean (4 Won) 14 Thai (5, Baht) 15 Chinese (¥, Yuan) NOTE: To use these symbols, select the internal symbol set.
D3. secondary
Secondary Sign. Options: 0 No secondary sign (default for all printers) 1 Print secondary sign NOTE: Secondary symbols only print if you designate at least one decimal place.
D4. decimals
Example
Number of digits to the right of the decimal. Options: 0 No digits 1 One digit 2 Two digits (default for all printers) 3 Three digits
{I,D,1,1,2 p }
Prints the dollar sign, uses a secondary symbol, and places two digits to the right of the decimal. 3-12 Configuring the Printer
Page 35
Defining the Control Characters Packet Use the control characters packet (E) to change the MPCLII control characters, enable and disable the immediate commands, and change the default terminator character for job requests and ENQ’s. Changes take effect with the first character following the end of header character } of the configuration packet. Each control character must be unique and cannot appear anywhere else in your packet, except within quotation marks. You can customize the trailer characters to work with your host. Wait two seconds for the new characters to take effect before sending packets using the new characters. Use the following syntax for the control characters packet. Notice all but the first parameter are within quotation marks. Syntax
{I,E,"ANSI_cd","string1","string2" p }
E1. E
Control Characters Packet
E2. "ANSI_cd"
~123 ~044 ~034 ~124 ~125 ~126 def. ch.
Start of header { (left bracket) Parameter , (comma) separator Quoted strings " (quotes) Field separator p (pipe sign) End of header } (right bracket) Data escape ~~ (double tilde) character (optional) Immediate command character (optional). Up to any 3 digits in the 0 to 255 decimal range. The tilde (~) must be used with decimal characters. The character must be defined before this command can be used. The caret (~094) is normally used.
NOTE: "ANSI_cd" includes seven separate parameters. The first five parameters are required. The other parameters are optional.
Configuring the Printer 3-13
Page 36
E3. "string 1"
Terminator for status requests and ENQ requests. Up to any 3 digits in the 0 to 255 decimal range. The tilde (~) must be used with decimal characters. The default is "013". Sending "" disables this sequence.
E4. "string 2"
Terminator for job requests and data uploads. Up to any 3 digits in the 0 to 255 decimal range. The tilde (~) must be used with decimal characters. The default is none. Sending "" disables this sequence.
After you change these parameters, all packets, including any future configuration packets, must use the new control characters. Monarch recommends using the tilde and ASCII character code sequence when sending this packet multiple times. Also, set the packet delimiters to characters within the 21 hex to 7E hex range. You must send the control characters packet to enable the immediate commands. An immediate command will execute immediately, even if it is embedded within quotation marks, and all data following the command in the string will be ignored. Example
{I,E,"~123~063~034~124~125~126~094" p }
Changes the parameter separator character from , to ?. The other control characters remain unchanged. It also enables the immediate commands by defining the ^ symbol as the command identifier.
Resetting Control Characters You can change the characters in the previous example back to their original settings by downloading this packet: Example
{I?E?"~123~044~034~124~125~126~094" p }
Notice that the parameter separator is ? in this packet. This is the parameter separator that was set before this packet. Once the packet is received by the printer, the new parameter separator (a comma, in this case) is valid.
3-14 Configuring the Printer
Page 37
Be careful when using this feature. If you forget what the control characters were changed to, print a test label. The test label lists the current control characters. See "Printing a Test Label," in Chapter 8 for more information.
Defining the Communication Settings Packet Use the communication settings packet (F) to set the baud rate, word length, stop bits, parity, and flow control for serial communications. To set parallel communications, see "Using Parallel Communications." Changing the communication settings takes approximately two seconds. Communications sent during this interval will be lost. Make sure the host communication values match the values on the printer. Syntax
{I,F,baud,word_length,stop_bits,parity, flow_control p }
F1. F
Communication Settings Packet
F2. baud
Baud Rate. Options: 0 1200 3 1 2400 4 2 4800 5
9600 (default for all printers) 19200 38400
F3. word_length
Word Length. Options: 0 7-bit word length 1 8-bit word length (default for all printers)
F4. stop_bits
Stop Bits. Options: 0 1-stop bit (default for all printers) 1 2-stop bits
F5. parity
Parity. Options: 0 None (default for all printers) 1 ODD parity 2 EVEN parity
F6. flow_control
Flow Control. Options: 0 None 1 DTR (default for all printers)
2 3
(CTS) XON/XOFF
NOTE: If you use the DOS COPY command to download your formats, set "Flow Control" to DTR (not XON/XOFF).
Configuring the Printer 3-15
Page 38
{I,F,3,1,0,0,1 p }
Example
Uses 9600 baud, an 8-bit word length, one stop bit, no parity, and the DTR mode.
Defining the Memory Configuration Packet Use the memory configuration packet (M) to customize the size of your printer’s buffers, which gives you greater flexibility in your formats. Memory must be allocated in 1/2K increments. The memory configuration packet does not accept decimals, so enter whole numbers. Multiply the amount to reallocate (in K) by 10. For example, To reallocate (in K)
Enter this amount
1
10
1.5
15
2
20
2.5
25
32
320
153
1530
229.5
2295
Each buffer’s allocated memory remains in effect until that buffer is reallocated. For this reason, you may want to reallocate all the buffers when reallocating any buffer. If you reallocate more memory than you have available, you will receive an error. Syntax M1. M
3-16 Configuring the Printer
{I,M,buffer,device,buffer_size p } Memory Configuration Packet
Page 39
M2. buffer
Buffer type: D F I R T V
Downloadable Fonts Format Image Receive Transmit Scalable (vector) Fonts
NOTE: The scalable font is not available for these printers. M3. device
Storage type. Options: N R
M4. buffer size
Non-volatile RAM (9412/9413 only) Volatile RAM (9414 only)
Buffer size in 1/10K ranges. See the following table for ranges.
Example
{I,M,I,R,1530 p }
Stores the image buffer in volatile RAM and allocates 153K for it. The following table lists the configured buffer sizes and min-max values for your printer. Buffer
Type
9412
9413/9414
Transmit
Non-Volatile
1K (.5K- 4K)
1K (.5K- 4K)
Receive
Non-Volatile
2K (2K- 64K)
2K (2K- 64K)
Image
Non-Volatile
67K (38.5K- 512K)
83K (38.5K- 512K)
Downloadable Fonts
Non-Volatile
10K (8K- 512K)
10K (8K- 512K)
Scalable Fonts
NA
NA
NA
Formats (Formats and Batches)
Non-Volatile
16K (16K- 512K)
16K (16K- 512K)
Internal
NA cannot reallocate cannot reallocate
The transmit and receive buffers are fixed and cannot be reallocated. The printer’s configuration is stored in non-volatile RAM and retained when you turn off the printer. Configuring the Printer 3-17
Page 40
Checking Current Buffer Sizes Send a configuration upload packet to check the sizes of your current buffers. See "Using Configuration Upload Packet" for more information. After you check your current buffer sizes you can begin reallocating memory. If you want to increase your image buffer and you will not be using scalable fonts, add that memory into your image buffer. Example
{I,M,R,N,20 p M,T,N,10 p M,D,N,80 p M,V,N,160 p M,I,N,3200 p }
Receive buffer 2K Transmit buffer 1K Downloadable fonts 8K Scalable fonts buffer 16K Image buffer 320K
Make sure memory is available before adding memory to a buffer. In the above example, if the image buffer (M,I,N,3200) was defined before the downloadable fonts and scalable fonts buffers (M,D,N,80 and M,V,N,160) were defined, an error would have occurred.
About Memory Buffers Transmit Buffer
Used to send ENQ, job, and upload responses. This buffer must be allocated as non-volatile (N) RAM.
Receive Buffer
Used to save data received from the host before it is processed by the printer. Changing this buffer size affects the amount of data the printer can receive without using flow control. This buffer must be allocated as non-volatile (N) RAM.
3-18 Configuring the Printer