Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 19

Monarch 9412, 9413, 9414 Printers, pages 21 to 30

Pages 21 to 30 of 184

The original document is the PDF (1.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Monarch 9414 and Paxar 9414

Page 21

Using the Format Worksheet The Format Worksheet is divided into sections that list the field types. Each section has boxes to fill in with parameters that define your format. A format worksheet is included in Appendix D, "Format Design Tools."

Filling in the Format Worksheet Decide what type of field to use on your label. 1. Make a copy of the Format Worksheet. 2. Define the Format Header. 3. Define all non-printable text fields before you define the ones you want to print. See "Defining Non-printable Text Fields" in Chapter 4 for more information. 4. Define options as you require them. See Chapter 5, "Defining Field Options" for more information.

Designing a Format 2-7

Page 22

2-8 Designing a Format

Page 23

CONFIGURING THE PRINTER

3

This chapter discusses how to u set communication parameters.

u upload the printer’s configuration or font information.

u configure the printer using online configuration packets.

u use immediate commands to control the printer’s operation at any time.

Configuring the Printer 3-1

Page 24

Setting Communication Parameters Use the following information for serial communications. See "Using Parallel Communications" for information about parallel communications. The communication parameters at the printer must match those at the host, or you will not be able to communicate. You can use the communication settings packet to set communication parameters for your printer. On MS-DOS computers, you can use the MODE command to set communication values on your PC. For example MODE COM1:9600,N,8,1 This command sets your host to these communication values: u a baud rate of 9600 u no parity u

8 bit word length u

1 stop bit

Using Parallel Communications If your printer supports parallel communications, the parallel port is Centronics®-compatible. The communication settings are automatically configured for you. There are no operator settings required.

3-2 Configuring the Printer

Page 25

Using MPCLII Conventions Here are some guidelines to follow when using MPCLII.

MPCLII Punctuation Use the following symbols when creating MPCLII packets: { start of header

} end of header p field separator

, parameter separator

"ABC"

Quotation marks enclose character strings. Empty quotes ("") identify null strings or unused fields.

‘comment‘

Grave accents enclose comments. Any data enclosed in grave accents is ignored. Do not embed comments within a quoted string. Grave accents are also used to reject mainframe data.

These MPCL characters are the default. See "Defining the Control Characters Packet" to change these characters.

Standard Syntax Guidelines When creating MPCLII packets: u

Begin each packet with a start of header ({).

u

End each packet with an end of header (}).

Configuring the Printer 3-3

Page 26

u

Define no more than 1000 fields in a format. Each p indicates one field. However, options are not counted as fields. The actual number of fields a format can have may be less, because the number of fields is limited by the available memory.

u

The field number 0 to 999 must be unique. Monarch recommends starting at 1, instead of 0.

u

Do not use a field number more than once per format.

u

Define all fields in the order you want to image/print them. The printer does not print in field number order.

u

Separate all parameters with a Parameter Separator (,).

u

End each field with a Field Separator ( p ).

u

Enter all information in CAPITAL letters, except words or phrases within quotation marks.

u

Include all field parameters unless documented as optional.

u

Define non-printable text fields before the field to which they apply.

u

Define options immediately after the field to which they apply.

u

Multiple options can be used with most fields. Options can be used in any combination except as noted with each definition.

u

Keep in mind that proportionally spaced fonts need wider fields than monospaced fonts. For variable field data, use a letter "W" to determine the maximum field size.

u

Do not place a new line (return) or any other non-printing character in a character string. However, a carriage return or line break after each p makes your formats easier to read. T,1,20,V,30,30,1,1,1,1,B,C,0,0,0 p T,2,10,V,50,30,1,1,1,1,B,C,0,0,0 p u

Spaces are ignored, except within character strings.

u

Indenting options improves readability of your formats. T,1,18,V,30,30,1,1,1,1,B,C,0,0,0 p R,42,1 p u

Use a tilde (~) followed by a 3-digit ASCII code in a quoted string to send function codes or extended characters.

3-4 Configuring the Printer

Page 27

You can modify formats and fields with the optional entry method. See "Optional Entry Method" in Chapter 6 for more information.

Using Online Configuration Packets Use online configuration packets to change the printer settings. You can send an individual packet or a packet that contains all seven online configuration packets. You can supply all parameters for each packet. Leave the parameters blank that you do not need to change. For example, {I,A,,,,1 p } prints a slashed zero and uses the last sent online System Setup parameters. Make a copy of the online configuration worksheet in Appendix D, "Format Design Tools," and save the original. Packets A-M are listed on the worksheet. When you turn off the printer, all the information in the online configuration packets is saved and used when the printer is turned back on. After you change printer configurations, you must resend the format or batch to the printer before the changes take effect.

Configuration Packet Header Always include an I, immediately after the left bracket { and before the packet identifier (A, B, C, etc.). The I parameter identifies the data stream as a configuration packet. Include the I parameter with each packet if you are sending them individually. Include it only at the beginning of a data stream if you are sending multiple packets.

Configuring the Printer 3-5

Page 28

This is the syntax to use when you create online configuration packets: Syntax {I,1 to 7 optional packet A, parameter 1...parameter 5 p B, parameter 1...parameter 5 p C, parameter 1...parameter 5 p D, parameter 1...parameter 3 p E, parameter 1...parameter 9 p F, parameter 1...parameter 5 p M, parameter 1_parameter 4 p }

Start of Header, Configuration Header System Setup Supply Setup Print Control Monetary Formatting Control Characters Communication Settings Memory Configuration, End of Header

Syntax for single packet { I A, parameter 1...parameter 5 p }

Start of Header Configuration Packet Identifier System Setup End of Header

You can also add a configuration to non-volatile RAM or specify units for supply, print, and margin positions. If you use the optional parameters with the I packet, any online configuration packets following the split vertical bar ( p ) must specify distances using the selected units. Syntax

{header,ID#,action,device p}

1. header

Constant I

2. ID#

ID. Use 0.

3. action

Action. Options: A Add configuration U Upload User Configuration

4. device

Storage Device. Options: F Flash (9414 only) N Non-volatile RAM (9412/9413 default) R RAM (9414 default)

5. units

Units (optional parameter). Options: E English M Metric G Dots

3-6 Configuring the Printer

Page 29

Example

{I,0,A,N,E p C,0,25,0,0,0 p }

Adds a configuration to non-volatile RAM and specifies English units. It also uses the default contrast, moves print 0.25 inches closer to the bottom of the supply and does not change the margin adjustment, prints at the default print speed, and uses the default printhead width. If you do not use the optional parameters, the syntax for the online configuration packets does not change. For example, {I,C,0,50,0,0,0 p } uses the default contrast, moves print 50 dots (025 inches) closer to the bottom of the supply and does not change the margin adjustment, prints at the default print speed, and uses the default printhead width. Example

{I,0,U,N p }

Uploads the printer configuration from non-volatile RAM and returns the following to the host. A,0,0,0,0 p B,1,0,0,0,0,0 p C,0,0,0,0,0 p D,1,0,2 p E,"~123~044~034~124~125~126","~013~010","" F,3,1,0,0,1 p M,R,0,0,N,2424,0 p M,R,N,20 p M,T,N,10 p M,I,N,1259 p M,D,N,975 p M,F,N,160 p M,V,N,0 p } p

Configuring the Printer 3-7

Page 30

The parameters for each packet (A-M) are displayed. In the first line that begins with M, 0 is the total volatile memory available, 0 is the memory used in volatile RAM. 2424 is the total non-volatile memory available, 0 is the memory used in non-volatile RAM. The remaining lines beginning with M list the buffer sizes in 1/10K for the Receive, Transmit, Image, Downloadable Fonts, Formats, and Scalable Fonts Buffers. The scalable font is not available for these printers.

Configuration Syntax Guidelines When creating a printer configuration packet: u

Follow the "Standard Syntax Guidelines" listed at the beginning of this chapter.

u

Begin a packet with the configuration header (I).

u

Download multiple configuration packets within one packet or download a single configuration packet.

u

Include the first five ANSI codes, at a minimum, in the control characters packet.

u

If you change any of the online configuration packets, resend the format packet to the printer, so the configuration changes take effect.

u

Make sure the communication settings at the host match those at the printer.

3-8 Configuring the Printer