Page 21
CONNECTIONS
2
2
CONNECTIONS
2.1
TERMINAL CONNECTIONS TO THE HOST COMPUTER Before continuing with this phase be sure both the computer and the Minec 4x terminal are turned off.
CAUTION
2.1.1
RS232 Connection
The Minec 4x terminal can communicate to a Host computer via RS232 when it is inserted into its cradle. The terminal communicates to the cradle through the IrDA port and the cradle transmits data to the PC through an RS232 connection.
C
D B
A Key: A Host computer B Minec 4x terminal with cradle
C RS232 cable D Power supply
3
Page 22
Minec 4x
2
2.1.2
IrDA Direct Connection
An IrDA direct connection is possible if the host computer has an IrDA port. Place the terminal with its IrDA port in front of the host IrDA port as shown in the figure below.
C
B
D
A Key: A B
4
Host computer PC IrDA Port
C D
Terminal IrDA Port Minec 4x terminal
Page 23
CONNECTIONS
2.1.3
2
RF Connection
Minec 4x RF versions can communicate with the host using the on-board radio frequency module and an Access Point connected to the host computer.
A
B
Key: A) Minec 4x terminals B) Access points
5
Page 24
Minec 4x
2
2.2
CRADLE CONNECTION D
A
B C
E
F
Key: A Battery recharge contacts B Charging Status LED C Data Transfer LED
D IrDA window E RS232 serial port F Power supply connector
The Minec 4x cradle is a battery charger and also functions as a serial communication interface between the host computer and the IrDA optical interface on the Minec 4x terminal.
6
Page 25
CONNECTIONS
2.2.1
2
Cradle LED Indicators
The cradle has two LEDs: the left LED indicates the terminal battery status, the right LED indicates the data transfer between the cradle and the Host.
LED Charging Status
Data Transfer
2.2.2
STATUS green terminal battery charged / cradle powered amber terminal battery charging blinking data transfer between terminal and Host.
Terminal / Cradle Positioning
The correct positioning of the terminal on the cradle is with the battery recharge contacts and the IrDA port as shown in the figure below.
7
Page 26
Minec 4x
2
2.3
POWER SUPPLY
The Minec 4x terminal can be powered with the Minec 4x Power Supply which can be connected directly to the terminal, or through the Minec 4x cradle for battery recharging.
8