Page 61

I 2 of 5 Format: <Krstatus,check digit status,check digit output status,code length #1,code length #2> status: check digit status: check digit output status: 0 = Disabled 0 = Disabled 0 = Disabled 1 = Enabled 1 = Enabled 1 = Enabled code length #2: code length #1: Zero or any even Any even number number from 2 to from 2 to 64. Default 64. Default is 6. is 10. Example: To set Fixed Code Length #1 to 8 and Fixed Code Length #2 to 4, enter <Kr,,,8,4> or <Kr1,0,0,8,4>.

Code 93

Example: To change Code 93 to enabled enter <Kz1>.

Code 128 Format: <Ktstatus,fixed code length status,code length> fixed code code length: status: length status: 0 = Disabled Any number from 1 to 31. 0 = Disabled 1 = Enabled Default is 10. 1 = Enabled Example: To enable Code 128, enable Fixed Code Length, and set Code Length to 9, enter <Kt1,1,9>.

Narrow Margins Format: <Kostatus> status: 0 = Disabled

1 = Enabled

Example: To enable Narrow Margins, enter <Ko1>.

VS-310 Scanner User’s Manual

3-11

3–Serial Config.

Format: <Kzstatus,fixed code length status,code length> Code 93 status: fixed code code length: length status: 0 = Disabled Any number from 1 to 31. 0 = Disabled 1 = Enabled Default is 10. 1 = Enabled

Page 62

Chapter 3

Serial Configuration

Scanner Output Commands Relay-1 Format: <Kvoutput on,polarity,pulse width> output on (mode): pulse width polarity: 0 = Mismatch or Noread 0 = Negative (in 10 millisecond increments): 1 = Good Match 1 = Positive Any number from 0 to 255. 2 = Mismatch Default is 5 (50 ms). 3 = Noread

Example: To set Relay-1 to Mismatch and change Pulse Width to 40 ms, enter <Kv2,0,4> or <Kv2,,4>.

Relay-2 (RS-232 only)

3–Serial Config.

Format: <Kwoutput on,polarity,pulse width> output on (mode): polarity: pulse width 0 = Mismatch or Noread 0 = Negative (in 10 millisecond increments): 1 = Good Match 1 = Positive Any number from 0 to 255. 2 = Mismatch Default is 5 (50 ms). 3 = Noread

Example: To set Relay-2 to Mismatch and change Pulse Width to 40 ms, enter <Kw2,0,4> or <Kw2,,4>.

Bar Code Output Format: <Klstatus,when to output> status: when to output: 0 = As Soon As Possible 0 = Disabled 1 = End of Read Cycle 1 = Match 2 = Mismatch 3 = Good Read

Example: To set When to Output to End of Read Cycle, enter <Kl3,1>.

Noread Message Format: <Kkstatus,output> noread output: status: 0 = Disabled Any ASCII string up to 7 digits. Default is 1 = Enabled NOREAD. (< and > are not recommended) Example: To enable Noread Message and send the message “FAIL,” enter <Kk1,FAIL>.

3-12

VS-310 Scanner User’s Manual

Page 63

Beeper Format: <Kubeeper status,beeper speed> beeper speed: beeper status: 0 = Fast 0 = Disabled 1 = Slow

1 = On good

2 = On noread

Example: To set the beeper status to Noread and beeper speed to Slow, enter <Ku2,1>.

Laser On/Off Format: <KCstatus> status: 0 = Disabled

1 = Enabled Example: To enable Laser On/Off, enter <KC1>.

Scanner Setup Commands software.

Scanner Type Caution: Do not change the scanner density type unless instructed to do so by a Microscan representative. Format: <KPdensity> scanner density type:*

0 = Standard (100 scans per second) 1 = High Density (60 scans per second) * The “default” will depend on the type of scanner. Note: The scanner must be reset for this parameter to take effect.

VS-310 Scanner User’s Manual

3-13

3–Serial Config.

Note: The following command is not available in the VS-310 ESP

Page 64

Serial Configuration

3–Serial Config.

Chapter 3

3-14

VS-310 Scanner User’s Manual

Page 65

Chapter

Utilities

4

Chapter Contents Summary of Operational Serial Commands ........................................ 4-2 Using ESP for Operations.................................................................... 4-3 Read Rate............................................................................................ 4-4 Trigger.................................................................................................. 4-5 Scanner................................................................................................ 4-6 Counters .............................................................................................. 4-7 Master Label ........................................................................................ 4-9 Reset.................................................................................................. 4-11 Checksum/Part Number Commands ................................................. 4-13 Other Operational Commands ........................................................... 4-13 Terminal Mode ................................................................................... 4-14

VS-310 Scanner User’s Manual

4-1

4–Utilities

Operational commands for the VS-310 can be entered as serial command strings (Table 4-1 on page 4-2) or, in most cases, as menu selections via the Easy Setup Program. This chapter includes both operational serial command strings and corresponding ESP commands. Menu commands are listed where appropriate. For configuration changes using ESP, see Chapter 2, “Configuration Setup File.”

Page 66

Chapter 4

Utilities

Summary of Operational Serial Commands Table 4-1 Summary of Operational commands

Command Type Read Rate Trigger

Scanner Control

Counters

4–Utilities

Master Label

Reset

Check Sum Part #

Code Types

ESP Cmd?

Serial Command

Name

Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes Yes No No No No

<C> <Cp> <J> <char> <H> <I> <KE> <KF> <L1> <L2> <N> <O> <T> <U> <V> <W> <X> <Y> <E> <F> <G> <)XXXX)> <)> <))> <A> <Ad> <An> <Z> <Zp> <!> <#> <P> <Q> <R> <S>

Enter Decode Rate Test Enter Percent Rate Test Exit Decode Rate and Percent Rate Test Serial Trigger Character Enable Laser Scanning (Laser On) Disable Laser Scanning (Laser Off) Motor On Motor Off Relay-1 Pulse Relay-2 Pulse (not available with RS-422 option) Noread Counter Noread Counter Reset Trigger Counter Trigger Counter Reset Good Read Counter Good Read Counter Reset Mismatch Counter Mismatch Counter Reset Enable Match Code * Disable Match Code* Store Next Label Scanned as Master Label Download Master Label Information Request Master Label Information Delete Master Label Information Software Reset (does not save for power-on) Software Reset/Restore Default Software Reset/Read NOVRAM Software Reset/Save Stnd Parameters for Power-on Save Scanner Type for Power-on Display Checksum of EPROM Display Software Part Number Autodiscriminate All Codes Enable Code 39 Only* Enable Codabar Only* Enable I 2 Of 5 Only*

*Can also be set in the configuration menu or with a serial configuration command.

4-2

VS-310 Scanner User’s Manual

Page 67

Utilities

Using ESP for Operations When the program is first loaded, the menu bar and toolbar will appear as in figure 4-1.

Figure 4-1 Partial Menu Selection

Most operational commands can be accessed from the UTILITIES button (figure 4-2) or from Utilities in the pull down menu.

Figure 4-2 Utilities Menu

Clicking Terminal in the Utilities menu or from the status menu opens up a terminal window on the right side of your screen and activates Go, Stop, and clear screen buttons on the right end of the tool bar as shown in figure 4-3. Clear Screen Button

4–Utilities

Figure 4-3 Full Menu Selection

VS-310 Scanner User’s Manual

4-3

Page 68

Chapter 4

Utilities

Read Rate You can test read rate by clicking Utilities and Read Rate from the pulldown menus, or from the settings window clicking the Utilities button and clicking the Read Rate tab as in figure 4-4.

Figure 4-4 Read Rate

Enter Percent Test Clicking Percent and Start or sending serial command <Cp> instructs the scanner to output the percent of decodes and any scanned label data.

Enter Decodes/Second Test Clicking Decodes/Second and Start or send33 Decodes/Sec 0123456 ing serial command <C> instructs the scanner to output the decodes per second and label 33 Decodes/Sec 0123456 data (if any). The decode rate can vary dra33 Decodes/Sec 0123456 matically due to the angle and location of the 33 Decodes/Sec 0123456 label in relation to the scan beam (or scan 33 Decodes/Sec 0123456 line, if using a scan head with a moving beam). This test is very useful in aligning and positioning the scanning device during installation.

End Read Rate Test

4–Utilities

Clicking Stop or sending serial command <J> ends both the Percent test and the Decodes/Second test.

4-4

VS-310 Scanner User’s Manual

Page 69

Utilities

Trigger You can define, set up, and send the serial trigger character via ESP by clicking Utilities and Serial Trigger from the pull-down menus or, from the settings window, clicking Utilities and Trigger as shown in figure 4-5. The Trigger card also provides a blank screen to review label data in response to triggers generated by the Send command.

Figure 4-5 Serial Trigger Commands

A serial trigger initiates a read cycle in the scanner. It is defined in the ESP Operations menu (see “Multilabel Separator,” on page 2-15) or by serial configuration command (as <Ki_>).

Setup Clicking SETUP uploads the current serial trigger character from the scanner. Note: Must be in point-to-point protocol for Setup to work.

Send Clicking SEND sends a trigger character to the scanner, with Serial Trigger Mode enabled, click the SEND button. or by serial configuration command (<Ki..>).

VS-310 Scanner User’s Manual

4-5

4–Utilities

Note: The serial trigger character can be changed in the Operations menu,

Page 70

Chapter 4

Utilities

Scanner You can control the laser status, relay pulses, and the mirror motor via ESP by clicking Utilities and Scanner from the pull-down menus or, from the settings window, clicking the Utilities button and clicking the Scanner tab as in figure 4-6.

Figure 4-6 Scanner Controls

Enable Laser Scanning Clicking the Laser On button or sending serial command <H> will turn the laser on continuously. Note: Enable Laser Scanning does not relate to Laser On/Off command

(see page 2-23).

Disable Laser Scanning Clicking Laser Off or sending serial command <I> will turn the laser off. This feature is useful during extended periods of time when no bar code labels are being scanned or the scanner is being configured. Disabling laser scanning will not affect any downloaded commands to the scanner.

4–Utilities

Note: Disable Laser Scanning does not relate to Laser On/Off command

(see page 2-23).

Motor On Clicking Motor On or sending serial command <KE> turns the motor on (reaches full speed after a short time delay).

Motor Off Clicking Motor Off or sending serial command <KF> turns the motor off. This command is useful for long idle periods.

Relay-1 Pulse Clicking Relay #1 Pulse or sending serial command <L1> sends a pulse to pin 2 (at any time regardless of Match Code or Relay-1 Driver status).

Relay-2 Pulse (not available with RS-422 option) Clicking Relay #2 Pulse or sending serial command <L2> sends a pulse to pin 8 (at any time regardless of Match Code or Relay-2 Driver status).

4-6