Page 31

2 Using ESP Contents Verification ....................................................................................................................................2-2 Application Mode...........................................................................................................................2-3 Menu Toolbar ................................................................................................................................2-4 View ............................................................................................................................................2-11 Navigating in ESP .......................................................................................................................2-12 Send/Receive Options ................................................................................................................2-13

This section is designed to help you understand the structure, elements, and application of ESP. When you open ESP, unless otherwise specified in the ESP Preferences dialog accessible from the Options heading on the menu toolbar, you will enter EZ Mode for initial setup. From there, you can enter Application Mode (App Mode) and access several configuration menus (Verification, Communications, Read Cycle, Symbologies, I/O Parameters, Symbol Quality, Matchcode, and Diagnostics), a Camera setup interface, a Terminal interface, a Utilities interface, and an Output Format interface. ESP can be used to configure the Quadrus Verifier in three different ways: • Tree Controls: Each configuration menu contains a list of all option settings that pertain to that specific element of Verifier operation. For example, the Communications menu shows a Host Port Connections option, and then a list of the sub-options Baud Rate, Parity, Stop Bits, and Data Bits. Each of these sub-options is configurable by using dropdown menus. • Graphic User Interfaces: Settings can be configured using such point-and-click tools as radio buttons, zoom in/zoom out sliders, spin boxes, check boxes, and drag-and-drop functions. • Terminal: ESP’s Terminal interface allows you to send serial configuration and utility commands directly to the Verifier by typing them in the provided text field. For ESP system requirements, see System Requirements for ESP in Quick Start.

Quadrus Verifier User’s Manual

2-1

Page 32

Verification

Verification In the Verification view you are presented with the Locate and Calibrate options. After connecting to the Verifier, Verification is the first view you will see. You will be provided with on-screen instructions that will help you with symbol positioning, location, and calibration. Enter App Mode to access configuration trees and other setup features. Click Calibrate to begin the initial calibration routine. Calibration and grading are explained at the left of the Verification screen.

Click Locate to activate video. Center the symbol in the field of view.

Locate When you click Locate, the video view be activated. This allows you to center the candidate symbol in the Verifier’s field of view before beginning the calibration routine.

Calibrate Reflectance Calibration is required for ISO/IEC 15415 verification.

Illumination The Illumination dropdown menu allows you to configure LED behavior from the Verification view. See Illumination Source for further detail about LED illumination options.

2-2

Quadrus Verifier User’s Manual

Page 33

Using ESP

Application Mode The Quadrus Verifier can be used as a reader as well as a verifier. ESP’s App Mode offers complete control of configuration parameters. From Verification, you can click on the App Mode button to access specific configuration menus, Utilities tools, Camera setup, Output Format options, and a Terminal window where serial commands can be entered. Note: The App Mode and EZ Mode buttons appear in the same position to allow easy switching between these primary modes. Camera Setup, Evaluation, Region of Interest, IP Database, Dynamic Setup. Click this icon to return to Verification.

Click here to open the Terminal view.

Click here for Ordered Output and Output Format features.

Menu toolbar.

Click on icons in this row to access configuration trees like the one at left. Click the Configuration icon to return to full App Mode view from Verification, Camera, Terminal, Utilities, or Output Format.

Decoded symbol data is shown in this table.

Click Capture and Decode to read the symbol in the field of view, and to see a high resolution image capture of the symbol.

Quadrus Verifier User’s Manual

2-3

Page 34

Menu Toolbar

Menu Toolbar File > New Whenever New is selected, the default configuration of ESP is loaded.

Open/Save When Save or Save As is selected, the ESP configuration is saved to the host computer’s hard drive and available whenever the same file is selected under Open. Important: When you save menu changes to your hard drive, these changes are not saved to your Verifier. The illustration below shows how settings can be saved and received between ESP and the Verifier, and ESP and the host hard drive.

(Save to Verifier)

(Receive Verifier Settings)

Import/Export Import converts the ASCII settings from a text file to ESP configuration settings. Export converts the active ESP configuration settings to an ASCII text file.

2-4

Quadrus Verifier User’s Manual

Page 35

Using ESP

Model In Model you can select any of the models shown in ESP’s model menu. When you choose another model, your current connection to your present model will be terminated. To connect to another model, select New Model, choose a new model from the menu, and click OK.

Note: All the models you have enabled by selecting will continue to appear in the Model menu and that the same menu is repeated when clicking the Switch Model icon.

When you save your ESP file, you will be saving the settings of all the models defined in a single ESP file. Quadrus Verifier User’s Manual

2-5

Page 36

Menu Toolbar

Options The Options menu allows you to save memos and set up ESP Preferences. Note: Preferences will be saved and loaded into ESP when ESP is opened next, whether or not you save the ESP file.

Preferences General Tab

Reload Last File At startup, reloads the last file saved to the host computer’s hard drive. Show Model Prompt At startup, remembers the last connected model and displays it in the Connecting... dialog whenever you attempt to connect. Show Connect Prompt At startup, displays the Would you like to connect...? prompt. Receive After Connect At startup, loads the Verifier’s settings into ESP. (This is not recommended if you want to preserve your ESP settings for future use.) Enable ‘Send and Save as Customer Defaults’ At startup, enables the Send and Save as Customer Defaults option in the Send/Recv command. 2-6

Quadrus Verifier User’s Manual

Page 37

Using ESP

Terminal Tab

When Show Non-Printable Characters is checked, characters such as “CRLF” will be displayed in the Terminal window. When Enhanced Format is checked, the characters are displayed with more detailed formatting. Change Keyboard Macros In this dialog you can first select the function key and then enter your macro keystrokes in the associated key map. For example, to make Ctrl-F5 the keystroke to enable, send a trigger character, select F5, and then in the Ctrl row, enter <trigger character> and click OK. Then whenever the Ctrl-F5 keystroke is pressed, the trigger character will start the read cycle. Change Font Allows you to modify the font used for decode data received from the Verifier on the Terminal screen. Change Echo Font Allows you to modify the font used for command characters typed into the Terminal view.

Quadrus Verifier User’s Manual

2-7

Page 38

Menu Toolbar

Bar Code Options Tab

The Bar Code Options dialog allows you to set the size (in mils) of user-created symbols. Sizing Information Sets the bar width (in thousands of an inch) of user-created symbols. A bar width of 14 is 0.014 inches.

2-8

Quadrus Verifier User’s Manual

Page 39

Using ESP

Advanced Tab

The Auto Sync dialog at the top of the Advanced tab allows you to determine whether Auto Sync will be automatically enabled in sections of ESP where it is used, or if it will ask you before it enables Auto Sync functions. Always Ask Before Auto Sync Occurs If you check this option box, you are then able to determine what specific Auto Sync functions will be enabled. Receive Settings from the Reader will automatically send the Verifier’s settings to ESP when Auto Sync is enabled. Send ESP Settings to the Reader will automatically send all Verifier configuration settings chosen in ESP to the Verifier. Do Not Send or Receive Settings creates a condition in which Auto Sync will not send Verifier settings to ESP, or send ESP settings to the Verifier. Send XON with Autoconnect Sends an XON (Begin Transmission) command to the Verifier before starting the Autoconnect routine.

Quadrus Verifier User’s Manual

2-9

Page 40

Menu Toolbar

Document Memo The information you type in the Document Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Document Memo item on the Options menu.

Model Memo Similar to Document Memo, the information you type in the Model Memo field will appear in a context-sensitive text box whenever your cursor hovers over the Model Memo item on the Options menu. Memos created in Model Memo are specific to the model enabled when the message was created.

Note: Memos must be saved in a .esp file if you want them to available in your next session. If you do not save your current session, any memos that you have entered during the session will be discarded, and will be unavailable in your next session.

2-10

Quadrus Verifier User’s Manual