Page 381
Utilities
Firmware Firmware by ESP
Firmware Update Application code versions are specific to your Verifier. Consult with your sales representative before downloading application code. If needed, an application code will be sent to you in the form of a *.mot file. To download application code: 1. First, be sure that your Verifier is connected to the host. 2. Apply power to the Verifier. 3. Before updating, you should verify the current firmware. 4. Click in the Firmware Update text box and select the file type you want to download. This will open a file locator box. 5. Navigate to the appropriate file (it will be a *.mot file) and open the file. Caution: Do not interrupt power or disconnect the host cable while download is in progress. Be sure that each download is complete before moving on to the next. Important: When updating firmware, be sure that the application code and boot code versions are mutually compatible.
Quadrus Verifier User’s Manual
14-13
Page 382
Firmware
Firmware Verification Request Part Number You can send a request to the Verifier for part numbers, checksums, boot code, and application code.
By ESP You can access Part Numbers from the Utilities menu. 1. Click the Firmware tab. 2. From the pulldown selection box to the left of the Request Part No. button, make your selection. 3. Select the code type to see its part number displayed in the text field to the right of the Request Part No. button.
By Serial Command • When you send <#> (a request for all product part numbers), the Verifier returns: <#b/BOOT_P/N><#a/APP_P/N><#p/PROFILE_P/N>. • When you send <#a> (a request for the application code part number), the Verifier returns: <#a/APP_P/N>. • When you send <#b> (a request for the boot code part number), the Verifier returns: <#b/BOOT_P/N>. • When you send <#p> (a request for profile module part numbers), the Verifier returns: <#p/PROFILE_P/N>.
14-14
Quadrus Verifier User’s Manual
Page 383
Utilities
Request Checksum You can send a request to the Verifier for part numbers, checksums, boot code, and application code.
By ESP You can access Checksum from the Utilities menu. 1. Click the Firmware tab. 2. From the pulldown selection box to the left of the Request Checksum button, make your selection. 3. Select the code type to see its checksum displayed in the text field to the right of the Request Checksum button.
By Serial Command • When you send <!> (a request for all available firmware checksums), the Verifier returns: <!b/BOOT_CHECKSUM><!a/APP_CHECKSUM><!p/PROFILE_CHECKSUM> • When you send <!a> (a request for the application code checksum), the Verifier returns: <!a/APP_CHECKSUM> • When you send <!b> (a request for the boot code checksum), the Verifier returns: <!b/BOOT_CHECKSUM> • When you send <!p> (a request for profile module checksum), the Verifier returns: <!p/PROFILE_CHECKSUM>
Quadrus Verifier User’s Manual
14-15
Page 384
Bar Code Configuration
Bar Code Configuration Definition:
Bar code configuration is a way of programming the reader by using Data Matrix ECC 200 symbols.
Serial Cmd:
<BCCFG>
Bar code configuration can be entered three different ways: 1. By forcing the reader into bar code configuration mode by serial command <BCCFG>. 2. By configuring one of the 4 EZ button positions to Bar Code Configuration Mode. 3. By reading a Data Matrix symbol with a special codeword used by ISO/IEC 15415 to signify reader programming. This can be either in a regular read cycle or in read rate routine. Reading this symbol in the calibration routine will have no effect. Once Bar Code Configuration mode has been entered, the Data Matrix symbols can be thought of as serial data. You can configure the reader by printing labels in Microscan’s serial command format. Commands are processed as if the data were streamed in through the serial port. The reader will acknowledge the symbol with a beep, green flash, and echo the serial data to the host. If the command causes the reader to produce more serial output such as serial verification or counter requests, the data will be routed to the host port. The Bar Code Configuration mode can be exited by any reset <A> or <Z> command, as well as a <J> or a quick press and release of the EZ button. The command to exit bar code configuration can be included as part of the bar code, for example, encoding <K200,4><K220,1><J> into a Data Matrix symbol. This would configure the reader to serial trigger mode, program a new trigger to end the read cycle, and exit the bar code configuration mode with the <J>. To end all EZ button functions, press the EZ button and quickly release.
14-16
Quadrus Verifier User’s Manual
Page 385
Utilities
Defaulting/Saving/Resetting Understanding and controlling your reader’s active, saved, and default settings is critical to the operation of your reader. Software Reset/Save/Recall Commands
Reset
<A>
ESP (first, right click in any menu tree)a Save to Reader, Send No Save
Reset and recall Microscan defaults Reset and recall power-on parameters Reset and recall customer default parameters Save current settings for power-on
<Ard>
No
No
<Arp>
No
No
<Arc>
No
No
<Z>
No
Save current settings as customer default parameters
<Zc>
Save to Reader, Send and Save Save to Reader, Send and Save Customer Defaultsb
<Zrd>
No
No
<Zrc>
No
Press and hold while powering on Reader
Saved for Power-on
Resets (not saved for power-on)
Function
Recall Microscan default parameters and save for power-on Recall customer default parameters and save for power-on
Serial Cmd
EZ Button No
No a. When you right click in a menu tree and select Default Current Menu Settings or Default All ESP Settings, it is important to note that only ESP settings are defaulted. To save these defaults to the reader itself, you need to follow up with a <Z> or Save to Reader, Send and Save command. b. Only available in ESP if enabled under the Options pulldown menu.
Resets Resets (<A> commands) affect only the current settings (active memory) and are not saved for power-on.
Saved for Power-On Power-on parameters (<Z> commands) are saved to NOVRAM and recalled and loaded into current parameters when power is cycled or the <Arp> command is issued.
Defaults Defaults are Microscan firmware settings or saved customer settings that can be recalled, either by software or hardware reset.
Quadrus Verifier User’s Manual
14-17
Page 386
Defaulting/Saving/Resetting
Customer Default Parameters Customer default parameters (saved by <Zc>) are the same set of parameters as power-on parameters but are saved in a different, isolated section of NOVRAM. This allows a user to essentially create a backup set of parameters that can be recalled in the event that the current parameters or power-on parameters have been accidentally changed or no longer desired. It is important to note that a hardware default does not affect customer default parameters. For example, a user that has inadvertently changed communication settings and saved them with a <Z> command, may not know the correct settings or doesn't have the capability to communicate at those settings. By first doing an EZ button or hardware default to restore the known Microscan defaults, the user can then recall the previously customer saved settings with an <Arc> or <Zrc> command.
Microscan Default Parameters Microscan default parameters are contained in the firmware and cannot be changed.
Software Defaults Microscan default parameters can be recalled (loaded into current settings) with <Ard> command or recalled and saved for power-on with the <Zrd> command.
Hardware Default If a software default reset is not possible, it may be necessary to reset the reader by shorting (connecting) specific pins. This procedure has the same effect as the <Zrd> software command. Important: For this reset to occur, this command must be executed within 60 seconds after a power-on or a reset. 1. Apply power to the reader. 2. If using an IB-150 Interface Kit, locate pins 7 and 11 on the host connector. Caution: Be certain that the correct pins are located. Connecting the wrong pins could cause serious damage to the unit. 3. Momentarily connect these wires (or pins) and listen for a series of short beeps. 4. Within 3 seconds, connect them again. A longer beep should be heard. If not, repeat the process.
Default on Power-On You can also use the EZ button to default the reader by holding down the EZ button while applying power to the reader, provided that this feature is enabled in Default on Power-On (EZ Button).
14-18
Quadrus Verifier User’s Manual
Page 387
Utilities
Status Requests <?> Status Byte The Verifier responds to a status request <?> with a two character hex value, such as <?/22>. To determine status: 1. Look up the binary conversion in the table below. For example, the first hex 2 would be 0 0 1 0 in binary, as read from binary digits 3 through 0; the second hex 2 is also 0 0 1 0 as read from binary digits 7 through 4. 2. Next, enter your binary values from the table below in the “Binary” column next to the appropriate bit. Binary Bit 0 1 2 3 4 5
Binary 0 1 0 0 0 1
Verifier Status Command error detected Command received Communication error detected Flash sector unprotect failure Host/Aux port buffer overflow Verifier is in a read cycle
3. Under “Binary,” interpret 1s as true and 0s as not true. For example, bit 1 has a 1 in the “Binary” column, indicating “Command Received”. Bit 5 is also a 1, indicating that the “Verifier is in a read cycle”.
<K?> All Status Request
Hex Value 0 1 2 3 4 5 6 7 8 9 A B C D E F
Bit Digits 7
6
5
4
3
2
1
0
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
0 0 0 0 1 1 1 1 0 0 0 0 1 1 1 1
0 0 1 1 0 0 1 1 0 0 1 1 0 0 1 1
0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1
This is the fastest way to learn the Verifier’s current configuration. Sending this request will return the current settings of all commands, starting with the lowest K command value and ending with the highest K command value.
<K??> All Descriptor Status Request This request will return all current descriptors for every K command, starting with the lowest K command value and ending with the highest K command value.
<K?#> All Range Status Request This request will return the current settings of all commands within the user-defined range, starting with the lowest user-defined K command value and ending with the highest userdefined K command value.
Quadrus Verifier User’s Manual
14-19
Page 388
Status Requests
<Knnn?> Single Status Request This request will return the value of the variables associated with the requested K command. The request of a single entry of a database command cannot exceed the number of database slots for the specific command.
<Knnn??> Single Descriptor Status Request This request returns the basic functional description of all fields in the requested K command.
<Knnn?#> Single Range Status Request This request will return the value range and storage type description of all fields in the requested K command.
14-20
Quadrus Verifier User’s Manual
Page 389
Utilities
Other Operational Serial Commands The following serial utility commands can be entered from ESP’s Terminal window or a PLC:
Y-Modem Upload Transfer Options <uy,path,filename>
Y-Modem Download Transfer Options <dy,path,filename>
Image Library Request <op,9> Manages files in a selected directory. File Source (Nothing) / /saved *.* /del /saved/del del*.*
Explanation All files in “root” directory All files in “root” directory All files in “saved” directory All files in all directories Deletes all files in the root director Deletes all files in the saved directory Deletes files in all directories
Quadrus Verifier User’s Manual
14-21
Page 390
Status Requests
14-22
Quadrus Verifier User’s Manual