Page 161

Communications

RS-232 Auxiliary Port The auxiliary port offers an alternative port that can be configured to communicate in RS-232 in several modes including Daisy Chain.

Auxiliary Port Connections As with the host port parameters, the auxiliary port settings (baud rate, parity, stop bits, and data bits) must be identical with those of the auxiliary device. Note: Aux port connections are not available when Ethernet is enabled. Usage:

An auxiliary port connects the reader to a remote display or to other readers that can display or transfer data.

Definition:

These commands set the communication parameters with the auxiliary port which can be used to configure menus, send data to the host, display data transmissions originating from the host, and relay data from other readers set in tandem (daisy chained).

Baud Rate, Aux Port Usage:

Can be used to transfer data faster or match an auxiliary device.

Definition:

The rate at which the reader and host transfer data back and forth.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Default:

115.2K

Options:

0 = 600 3 = 4800 6 = 38.4K

1 = 1200 4 = 9600 7 = 57.6K

2 = 2400 5 = 19.2K 8 = 115.2K

Parity, Aux Port Usage:

Only changed if necessary to match host setting.

Definition:

An error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Default:

None

Options:

0 = None

Quadrus Verifier User’s Manual

1 = Even

2 = Odd

5-9

Page 162

RS-232 Auxiliary Port

Stop Bits, Aux Port Usage:

Only changed if necessary to match host setting.

Definition:

Allows the user to select the last one or two bits in each character to indicate the end of the character.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Default:

One

Options:

0 = One

1 = Two

Data Bits, Aux Port Usage:

Only changed if necessary to match host setting.

Definition:

Number of bits in each character.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Default:

Eight

Options:

0 = Seven

1 = Eight

Auxiliary Port Mode Definition:

Determines the flow of data between the auxiliary port device(s), the reader, and the host.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Default:

Disabled

Options:

0 = Disabled 3 = Full duplex

1 = Transparent 4 = Daisy chain

2 = Half duplex 5 = Command Processing

Note: RS-232 host and aux port are available with full functionality.

5-10

Quadrus Verifier User’s Manual

Page 163

Communications

Transparent (Auxiliary Port Mode) Usage:

A common application, in conjunction with handheld readers, is one that employs an auxiliary readout to detect mis-applied symbols.

Definition:

In Transparent mode data is passed between the auxiliary port and the host. The reader buffers data from the auxiliary port and echoes the keyed data on the auxiliary port. • Auxiliary port data is passed through to the host Aux whenever a return key is pressed at the auxiliary Host Port port or whenever symbol data is sent. If sent with symbol data, it is processed on a first-in/first-out basis. • Auxiliary port data to the host is always sent with Verifier a preamble and a postamble. • If the reader is in a polled mode to the host, auxiliary port data will still pass through. • <D> is the only command accepted by the reader from the auxiliary port. All other commands will pass through to the host. Data initiated from the Verifier • Transmission to the auxiliary port occurs immediately upon a good read. • Data sent to the auxiliary port does not include a preamble or a postamble. • Communications with the auxiliary port is always in Point-to-Point protocol, even if the host is in a polled protocol mode. Data initiated from the Host • All host data is echoed to the auxiliary port in unpolled mode.

Host

Aux Port

Verifier

Host

Aux Port

Verifier

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID> 1 = Transparent

Quadrus Verifier User’s Manual

5-11

Page 164

RS-232 Auxiliary Port

Half Duplex (Auxiliary Port Mode) Usage:

Useful when the user wants symbol data displayed on an auxiliary menu close to the reader.

Definition:

In Half Duplex mode all auxiliary port data and symbol data is sent directly to the host. Symbol data is displayed on the auxiliary port menu at the same time the data is sent to the host. Data initiated from the Auxiliary Port • Auxiliary port data to the host is ignored if the reader Aux is in a polled mode. Host Port • Auxiliary port data or read data is sent to the host whenever it is received. • Auxiliary port data is not echoed. Verifier • Auxiliary port data to the host is always sent without a preamble or a postamble. • <D> is the only command that is accepted by the reader from the auxiliary port. All other commands are passed through to the host. Data initiated from the Verifier • Data is transmitted to the auxiliary port at the same time it is transmitted to the host. • Data transmission conforms with all parameters specified in the configuration menu (e.g., Preamble, Postamble, End of Read Cycle).

Aux Port

Host

Verifier

Data initiated from the Host • All host data is echoed to the auxiliary port in unpolled mode.

Host

Aux Port

Verifier

Serial Cmd:

5-12

<K101,aux port mode,baud rate,parity,stop bits,data bits> 2 = Half Duplex

Quadrus Verifier User’s Manual

Page 165

Communications

Full Duplex (Auxiliary Port Mode) Usage:

When communication to and from the auxiliary port is required.

Definition:

In Full Duplex mode all auxiliary port data and symbol data is sent directly to the host. Symbol data is not displayed on the auxiliary port menu. Data initiated from the Auxiliary Port Aux • Auxiliary port data to the host is ignored if the Host Port reader is in a polled mode. • Auxiliary port data or read data is sent to the host whenever it is received. Verifier • Auxiliary port data is not echoed. • Auxiliary port data to the host is always sent without a preamble or a postamble. • <D> is the only command that is accepted by the reader from the auxiliary port. All other commands are passed through to the host. Data initiated from the Verifier • Data is not sent to the auxiliary port.

Host

Aux Port

Verifier

Data initiated from the Host • All host data is echoed to the auxiliary port in unpolled mode.

Host

Aux Port

Verifier

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID> 3 = Full duplex

Quadrus Verifier User’s Manual

5-13

Page 166

RS-232 Auxiliary Port

Daisy Chain (Auxiliary Port Mode) Usage:

Useful in applications where: • More than one symbol type is present. • A symbol may be present on multiple sides of a package. • Symbols are presented at different depths.

Definition:

In a daisy chain application, readers are connected in tandem or “daisy chain” and decoded data is relayed from one reader to another on up to the host. A master reader has its host port linked to the host computer and its auxiliary port linked to the host port of the first secondary reader in the chain. Thereafter, each secondary reader’s auxiliary port is linked to the host port of the secondary reader that is further from the host in the daisy chain. Each reader in the daisy chain can be assigned an ID that accompanies any data that it sends.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Options:

4 = Daisy chain

Function:

Before the master reader times out, it checks its auxiliary port for data. It should be set to wait at least 30 mS for each secondary reader in the daisy chain. If no data is received within the read cycle timeout, the master sends a No Read message to the host. Otherwise the complete data is sent. If for example the master reader is set to timeout in 120 mS, the first secondary reader downstream might be set to 90 mS, the next to 30 mS, and so on, thus assuring that at least 30 ms elapses between transmissions.a Daisy-chained readers can send a series of symbols by enabling Multisymbol and a common multisymbol separator. If the master reader does not receive the expected number of symbols, No Read messages are appended to the data string to make up the difference between the number of symbols enabled in Multisymbol and the number of symbols read. For example, a master and two secondary readers have Number of Symbols set to 3 and Multisymbol Separator defined as %. If the master and the first secondary reader do not find symbols, but the next secondary reader registers a good read, the transmitted results would be: symbol data % No Read % No Read a. The above example is based on the best case. Other factors such as baud rate, dynamic focus timing, number of characters in a given symbol, and the number of secondary readers in the daisy chain can affect timing and may need to be included in your calculations for complete accuracy.

5-14

Quadrus Verifier User’s Manual

Page 167

Communications

Command Processing Mode (Auxiliary Port Mode) Usage:

Allows user to send configuration from the Host port or the auxiliary port.

Definition:

When enabled, Command Processing allows commands to be entered via the aux port and direct externally triggered read cycle data in one of two ways: 1. Bar code data, including the serial trigger if used, will be transmitted to the last port from which a command was sent. 2. If the last command came from the host port, then externally triggered read cycle data will only be output to the host port.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Options:

5 = Command Processing

Daisy Chain ID Status Usage:

Used in a daisy chain setup in cases where the host needs to know which reader in a daisy chain setup sent the data.

Definition:

Each reader in a daisy chain can be assigned a one or two character ID that will appear in front of decoded data and identify its source.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Note: Enable/disable and length must be the same in all readers.

Daisy Chain ID Usage:

Used in a daisy chain setup in cases where the host needs to know which reader sent the data.

Definition:

A one or two character prefix which identifies the particular daisy chain reader from which the data is being sent.

Serial Cmd:

<K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID>

Default:

1/

Options:

Any one or two ASCII characters.

Quadrus Verifier User’s Manual

5-15

Page 168

RS-232 Auxiliary Port

Daisy Chain Autoconfigure Usage:

For quick setup and configuration of the daisy chain network.

Definition:

Daisy Chain Autoconfigure is issued to the master reader in the daisy chain and the software responds as follows: • Counts the number of secondary readers in the daisy chain. • Assigns an internal ID number (1...n) to each secondary reader, where the first secondary reader is number 1 (and its own ID being a 0). • Propagates the communications settings and the relevant operating modes of the master reader to the host and auxiliary ports of each secondary reader. • Resets each secondary reader. • Ensures that each secondary reader has acquired the new settings.

Serial Cmd:

<K150DAISY>

Note: All secondary readers must be set to Serial for Daisy Chain to function. When setting up a daisy chain operation, perform the following steps: 1. Set the master reader (the reader connected to the host) to Serial. This sets all the readers in the daisy chain to Serial when the command is carried out. Before Autoconfigure you must set the master reader to Serial (S): Host

S

Primary Reader

S

Secondary Reader

S

Secondary Reader

2. Send <K150DAISY> command. 3. If necessary, set the master reader to Edge. After Autoconfigure you may set the master reader to Edge (E) but the other readers must remain in Serial (S): Host

E

5-16

Primary Reader

S

Secondary Reader

S

Secondary Reader

Quadrus Verifier User’s Manual

Page 169

Communications

Daisy Chain Remote Secondary Reader ID Usage:

This command provides a handy way to assign custom daisy chain IDs to specific readers that were assigned during the daisy chain autoconfigure process.

Definition:

Assigns a new daisy chain ID to a daisy chain secondary reader. The command is sent to the master reader to configure the other secondary readers.

Daisy Chain Reader Number Definition:

Specifies the target reader (by sequential number) which will be receiving the new Daisy Chain ID. The master reader is always 0 (zero). All secondary readers are numbered 1...n in the order that they are connected. Note: These numbers are for assigning IDs only and are not changeable.

Serial Cmd:

<K151,daisy chain reader #,daisy chain reader ID>

Options:

1....n (0 for the master)

Daisy Chain Reader ID Definition:

A two-character user-defined ASCII message identifying a reader in the daisy chain.

Serial Cmd:

<K151,daisy chain reader #,daisy chain reader ID>

Default:

Sequential numbering of reader units resulting from the Daisy Chain Autoconfigure <K150> command; for example: ID Master = 1/; ID reader 1 = 2/; ID reader 2 = 3/; etc.

Options:

Any two characters except NULL, < , or >.

Note: After a secondary reader accepts a new ID, it automatically invokes a reset-with-save command.

Quadrus Verifier User’s Manual

5-17

Page 170

Network

Network These port options are mutually exclusive and predetermined according to the FIS type associated with the unit. For example, if you have an Ethernet enabled unit, you will not be able to use USB or RS-485 Multidrop commands. Network connections are made through the Ethernet/USB connector, but setup is done through RS-232 connections.

Ethernet See Chapter 16, Ethernet, for a more detailed discussion of Ethernet connections.

IP Address Definition:

The 32-bit address defined by the Internet Protocol in RFC 791 (version 4). The Internet Protocol is the network layer for the TCP/IP Protocol Suite. It is a connectionless, best-effort packet switching protocol.

Usage:

Use this to configure the reader with an IP address compatible with the host network. Note that this only takes effect when IP Address mode is configured for Static mode.

Serial Cmd:

<K125, IP address,subnet address,gatewayaddress,IP address mode, primary TCP port,video TCP port>

Default:

192.168.0.100

Options:

0.0.0.0 to 255.255.255.255

Subnet Definition:

The subnet portion of an IP address. In a subnetted network, the IP address is split into a subnet portion and a host portion using an address (subnet) mask. A bit mask is used to identify which bits in an IP address correspond to the network and subnet portions of the address.

Usage:

Use this to configure a subnet mask that is compatible with the host network and the reader's IP address.

Serial Cmd:

<K125,IP address,subnet address,gateway address,IP address mode, primary TCP port,video TCP port>

Default:

255.255.255.0

Options:

0.0.0.0 to 255.255.255.255

5-18

Quadrus Verifier User’s Manual