For the Microscan Verifier

Page 151

R eader Setup The Quadrus Verifier is equipped with a full feature set that enables it to be used as a reader in a wide variety of applications. The following sections describe how to set up and operate the Quadrus Verifier as a reader.

Quadrus Verifier User’s Manual

Page 152

Quadrus Verifier User’s Manual

Page 153

5 Communications Contents Communications by ESP .............................................................................................................. 5-2 Communications Serial Commands.............................................................................................. 5-3 RS-232/422 Host Port................................................................................................................... 5-4 RS-232 Auxiliary Port.................................................................................................................... 5-9 Network....................................................................................................................................... 5-18 Preamble..................................................................................................................................... 5-21 Postamble ................................................................................................................................... 5-22 Response Timeout...................................................................................................................... 5-23 LRC Status.................................................................................................................................. 5-24 Aux Port System Data Status ..................................................................................................... 5-25

This section tells how to set up communications parameters with the host and an auxiliary terminal. With Microscan’s ESP, configuration changes can be made in the ESP menus, then sent and saved to your reader. You can also send serial commands to the reader via ESP’s Terminal window.

Quadrus Verifier User’s Manual

5-1

Page 154

Communications by ESP

Communications by ESP

Click this button to enter Application Mode.

To open the entire contents of the tree control, hold down the Alt key and single-click the +. To close the entire contents of the tree control, hold down the Alt key and single-click the - .

Click this button to bring up the Communications tree control.

To open nested options, single-click the +.

To change a setting, double-click the setting and use your cursor to scroll through the options.

5-2

Quadrus Verifier User’s Manual

Page 155

Communications

Communications Serial Commands Host Port Connections Host Port Protocol Host 232/422 Status Auxiliary Port Daisy Chain Autoconfigure. Daisy Chain ID Ethernet Configuration Preamble Postamble Response Timeout LRC Aux Port System Data Status

Quadrus Verifier User’s Manual

<K100,baud rate,parity,stop bits,data bits> <K140,protocol> <K102,host 422> <K101,aux port mode,baud rate,parity,stop bits,data bits,daisy chain ID status,daisy chain ID> <K150DAISY> <K151,daisy chain reader #,daisy chain reader ID> <K125,IP address,subnet address,gatewayaddress,IP address mode,primary TCP port,video TCP port> <K141,status,preamble characters> <K142,status,postamble characters> <K143,response timeout> <K145,status> <K146,aux port system data>

5-3

Page 156

RS-232/422 Host Port

RS-232/422 Host Port The host port can be configured with RS-232 and RS-422 connections.

Host Port Connections These settings define the basic transmission speeds and digital standards that ensure common formatting.

Baud Rate, Host Port Usage:

Can be used to transfer data faster or to match host port settings.

Definition:

The rate at which the reader and host transfer data back and forth.

Serial Cmd:

<K100,baud rate,parity,stop bits,data bits>

Default:

115.2K

Options:

0 = 600 3 = 4800 6 = 38.4K

1 = 1200 4 = 9600 7 = 57.6K

2 = 2400 5 = 19.2K 8 = 115.2K

Parity, Host Port Definition:

An error detection routine in which one data bit in each character is set to 1 or 0 so that the total number of 1 bits in the data field is even or odd.

Serial Cmd:

<K100,baud rate,parity,stop bits,data bits>

Default:

None

Options:

0 = None

1 = Even

2 = Odd

Stop Bits, Host Port Definition:

One or two bits added to the end of each character to indicate the end of the character.

Serial Cmd:

<K100,baud rate,parity,stop bits,data bits>

Default:

One

Options:

0 = One

1 = Two

Data Bits, Host Port Definition:

One or two bits added to the end of each character to indicate the end of the character.

Serial Cmd:

<K100,baud rate,parity,stop bits,data bits>

Default:

8

Options:

0 = Seven

5-4

1 = Eight

Quadrus Verifier User’s Manual

Page 157

Communications

Host Port Protocol Usage:

In general, the point-to-point protocols will work well in most applications. They require no address and must use RS-232 or RS-422 communications standards.

Definition:

Protocols define the sequence and format in which information is transferred between the reader and the host, or in the case of Multidrop, between multiple readers and a concentrator.

Serial Cmd:

<K140,protocol>

Default:

Point-to-Point

Options:

0 = Point-to-Point 1 = Point-to-Point with RTS/CTS 2 = Point-to-Point with XON/XOFF 3 = Point-to-Point with RTS/CTS and XON/XOFF 4 = Polling Mode D 6 = User Defined

Point-to-Point (Standard) Usage:

Used only with RS-232 or RS-422.

Definition:

Standard Point-to-Point requires no address and sends data to the host whenever it is available, without a request or handshake from the host.

Serial Cmd:

<K140,0>

Point-to-Point with XON/XOFF Usage:

If an XOFF has been received from the host, data will not be sent to the host until the host sends an XON. During the XOFF phase, the host is free to carry on other chores and accept data from other devices. Used only with RS-232.

Definition:

This option enables the host to send the XON and XOFF command as a single byte transmission command of start (^Q) or stop (^S).

Serial Cmd:

<K140,1>

Quadrus Verifier User’s Manual

5-5

Page 158

RS-232/422 Host Port

Point-to-Point with RTS/CTS Usage:

A reader initiates a data transfer with an RTS (request-to-send) transmission. The host, when ready, responds with a CTS (clear-to-send) and the data is transmitted. CTS and RTS signals are transmitted over two dedicated wires as defined in the RS-232 standard. Used only with RS-232.

Definition:

Point-to-Point with RTS/CTS (request-to-send/clear-to-send) is a simple hardware handshaking protocol that allows a reader to initiate data transfers to the host.

Serial Cmd:

<K140,2>

Point-to-Point with RTS/CTS and XON/XOFF Usage:

Used only with RS-232.

Definition:

This option is a combination of Point-to-Point with RTS/CTS and Pointto-Point with XON/XOFF.

Serial Cmd:

<K140,3>

Polling Mode D Usage:

When in Polling Mode D, an address of 1 is automatically displayed on the configuration menu. However, during transmission, a 1C hex poll address (FS) and a 1D hex select address (GS) are substituted for the 1.

Definition:

Like Point-to-Point, Polling Mode D requires a dedicated connection to the host; but unlike Point-to-Point, it requires an address and must wait for a poll from the host before sending data.

Serial Cmd:

<K140,4>

User-Defined Point-to-Point Usage:

Useful for developing custom protocols in polled or unpolled mode.

Definition:

Allows the user to customize the point-to-point protocol.

Serial Cmd:

<K140,6,RES,address,REQ,EOT,STX,ETX,ACK,NAK,from host>

User-Defined Address Definition:

User Defined is considered to be in a polled mode only if an address has been assigned.

Serial Cmd:

<K140,6RES,address,REQ,EOT,STX,ETX,ACK,NAK,from host>

Default:

No address

Options:

Any ASCII character except NULL, < , or >.

5-6

Quadrus Verifier User’s Manual

Page 159

Communications

User-Defined Example Definition:

Example: ACK/NAK protocol can be configured using User Defined. The reader will transmit data to the host, when an ACK is received, it will carry on with its business. If a NAK or response timeout occurs, the reader will re-send the data to the host up to 3 more times before aborting. Tip: To use User Defined Point-to-Point, first select Point-to-Point <K140,0> and then User Defined <K140,6>. Example: To select an unpolled ACK/NAK User Defined protocol with LRC disabled, send <K140,0><K140,6,,,,,,,^F,^U><K145,0>. ACK and NAK will be displayed in the menu.

Serial Cmd:

<K140,6,RES,address,REQ,EOT,STX,ETX,ACK,NAK,from host>

Default:

No assignment

Options:

Any ASCII character except NULL. Control characters can be used to define RES through NAK in serial commands.

From Host Definition:

This option allows the handshaking protocol to be initiated from the host, if not configured in an unpolled mode. Messages sent to the host will include the reader’s defined protocol. The status of From Host determines if messages sent from the host to the reader must include the defined protocol. If From Host is disabled, the defined protocol is not included. If From Host is enabled, the defined protocol must be included.

Serial Cmd:

<K140,6,RES,address,REQ,EOT,STX,ETX,ACK,NAK,from host>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

Multidrop Usage:

A concentrator can be used to connect up to 50 devices to a single host port connection.

Definition:

Multidrop allows up to 50 devices to be connected to a single RS-485 host, with the reader assigned an unique address (from 01 to 50).

Multidrop Addresses:

Each address has its own separate poll and select address (from 1C to 7F hex).

Options:

01 through 50

Serial Cmd:

If selecting Multidrop (K140,5) an address must be defined and appended to the command string. Format: <K140,5,address>

When Multidrop is selected, the protocol characters for RES, REQ, etc. are assigned automatically.

Quadrus Verifier User’s Manual

5-7

Page 160

RS-232/422 Host Port

User-Defined Multidrop Usage:

This option is used when connecting to a concentrator or other device that does not match standard multidrop protocol. If selecting User Defined Multidrop (7), complete the format by either choosing new parameters or place commas where unchanged data fields occur.

Definition:

User Defined Multidrop allows the user to customize the polling protocol.

Serial Cmd:

<K140,7,RES,address,REQ,EOT,STX,ETX,ACK,NAK> For User Defined Multidrop, first select Multidrop <K140,5>, then User Defined Multidrop <K140,7...>.

Address:

Any single character (02 to 7E in hex) in the ASCII table can be assigned as the address character. The character chosen is used as the poll character and the subsequent ASCII character becomes the select character. For example, if a ^B (02) is selected as the address, ^C (03) becomes the select address that the host will use in sending host select commands.

Note: Any ASCII character except NULL (00) and a ^A (01) can be assigned as an address. Control characters can be used to define RES through NAK in serial commands. Note: Definitions of commands in User Defined and User Defined Multidrop must be duplicated in host applications to enable poll and select sequences to execute correctly during transmission. Note: Typically, parameters in User Defined Multidrop are defined by first enabling Multidrop, then enabling User Defined Multidrop. This pre-loads multidrop characters into the parameters. Then changes are made to individual characters to match the host or other requirements.

Host 422 Status Usage:

RS-232 is an industry standard. RS-422 is used where greater cable lengths are required and/or where noise interference is an issue.

Definition:

Host 422 if enabled allows communication through the 422 I/O lines. When Host 422 is enabled, RS-232 is disabled. When Host 422 is disabled, RS-232 is enabled.

Serial Cmd:

<K102,host 422>

Default:

Disabled

Options:

0 = Disabled

5-8

1 = Enabled

Quadrus Verifier User’s Manual