Page 331

Appendices

Configuration Database Number of Active Indexes Configuration Database Switch Timing

<K252,number of active indexes,number of database cycles> <K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status,laser on position,laser off position,laser power, background color> <K254,switch mode,frame count/time>

Number of Active Indexes Number of Active Indexes Serial Cmd: Default: Options:

<K252,number of active indexes,number of database cycles> 0 (Disabled) 0 to 10

Number of Database Cycles Serial Cmd: Default: Options:

<K252,number of active indexes,number of database cycles> 0 (Disabled) 0 to 255

Configuration Database Index Serial Cmd: Options:

<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 1 to 10 (database index number)

Gain Serial Cmd: Default: Options:

<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power,background color> 40 0 to 255

AGC Mode Serial Cmd: Default: Options:

<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed, framing status,laser on position,laser off position,laser power,background color> 2 = Continuous 0 = Disabled 1 = Leading Edge 2 = Continuous

QX-870 Industrial Raster Scanner User Manual

A-45

Page 332

Serial Commands Tracking Serial Cmd: Default: Options:

<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 40 5 to 127

Raster Top Serial Cmd: Default: Options:

<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 88 0 to 255

Raster Bottom Serial Cmd: Default: Options:

<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 167 0 to 255

Raster Speed Serial Cmd: Default: Options:

<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 10 0 to 80

Framing Status Serial Cmd: Default: Options:

<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power,background color> 0 = Disabled 0 = Disabled 1 = Enabled

Laser On Position Serial Cmd: Default: Options:

A-46

<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 10 10 to 90

QX-870 Industrial Raster Scanner User Manual

Page 333

Appendices Laser Off Position Serial Cmd: Default: Options:

<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power, background color> 95 15 to 95

Laser Power Serial Cmd: Default: Options:

<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,,framing status, laser on position,laser off position,laser power,background color> 1 = Medium 0 = Low 1 = Medium 2 = High

Background Color Serial Cmd: Default: Options:

<K253,index,gain,AGC mode,tracking,raster top,raster bottom,raster speed,framing status, laser on position,laser off position,laser power,background color> 0 = White 0 = White 1 = Black

Switch Timing Switch Mode Serial Cmd: Default: Options:

<K254,switch mode,frame count/time> 0 = Time 0 = Time 1 = Number of raster sweeps

Frame Count/Time Serial Cmd: Default: Options:

<K254,switch mode,frame count/time> 10 (100 ms) 1 to 65535 (in 10 ms increments)

QX-870 Industrial Raster Scanner User Manual

A-47

Page 334

Serial Commands

Symbologies Quiet Zone Background Color Symbol Ratios Composite AIAG Depth of Field Enhance Code 39 Codabar Interleaved 2 of 5 UPC/EAN Code 128 / EAN 128 Code 93 PDF417 Pharmacode DataBar Omnidirectional (RSS-14) DataBar Limited (RSS Limited) DataBar Expanded (RSS Expanded) MicroPDF417 Symbol Reconstruction

<K450,quiet zone status> <K451,background color> <K452,Code 39,Codabar,Interleaved 2 of 5> <K453,symbology status,separator status,separator> <K454,status,ID1,status1,ID2,status2,ID3,status3,ID4,status4, ID5a,ID5b,ID5c,status5, ID6,status6,ID7,status7,ID8, status8, ID9,status9,ID10,status10,ID11,status11,ID12,status12> <K456,DOF Enhance mode> <K470,status,check character status,check character output status, large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> <K471,status,start/stop match status,start/stop output status, large intercharacter gap,fixed symbol length status,fixed symbol length,check character type,check character output status> <K472,status,check character status,check character output status, symbol length 1,symbol length 2,guard bar,range mode status> <K473,mode,EAN status,supplementals status,separator status, separator character,supplementals type,UPC-E as UPC-A> <K474,status,fixed symbol length status,fixed symbol length, EAN status,output format,application record separator status, application record separator character,application record brackets, application record padding,separation factor> <K475,mode,fixed symbol length status,symbol length> <K476,status,raster sweep count,fixed symbol length status, fixed symbol length,unused,codeword collection> <K477,status,fixed bar count status,fixed bar count,minimum bar count,bar width mode,direction,fixed threshold value> <K482,status> <K483,status> <K484,status,fixed symbol length status,fixed symbol length> <K485,status,raster sweep count,fixed symbol length status, fixed symbol length> <K496,symbol reconstruction redundancy,symbol reconstruction effort>

Quiet Zone Serial Cmd: Default: Options:

A-48

<K450,quiet zone status> 3 = Narrow, Enhanced 0 = Standard 1 = Narrow 2 = Standard, Enhanced 3 = Narrow, Enhanced

QX-870 Industrial Raster Scanner User Manual

Page 335

Appendices

Background Color Serial Cmd: Default: Options:

<K451,background color> 0 = White 1 = Black

Symbol Ratios Code 39 Serial Cmd: Default: Options:

<K452,Code 39,Codabar,Interleaved 2 of 5> 1 = Standard 0 = Tight 1 = Standard 2 = Aggressive

Codabar Serial Cmd: Default: Options:

<K452,Code 39,Codabar,Interleaved 2 of 5> 1 = Standard 0 = Tight 1 = Standard 2 = Aggressive

Interleaved 2 of 5 Serial Cmd: Default: Options:

<K452,Code 39,Codabar,Interleaved 2 of 5> 1 = Standard 0 = Tight 1 = Standard 2 = Aggressive

Composite Symbology Status (Composite) Serial Cmd: Default: Options:

<K453,symbology status,separator status,separator> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Required

Separator Status (Composite) Serial Cmd: Default: Options:

<K453,symbology status,separator status,separator> 0 = Disabled 0 = Disabled 1 = Enabled

QX-870 Industrial Raster Scanner User Manual

A-49

Page 336

Serial Commands Separator (Composite) Serial Cmd: Default: Options:

<K453,symbology status,separator status,separator> , (comma) Any 7-bit ASCII character

AIAG Serial Cmd: Default: Options:

<K454,status,ID1,status1,ID2,status2,ID3,status3,ID4,status4,ID5a,ID5b, ID5c,status5,ID6,status6,ID7,status7,ID8,status8,ID9, status9,ID10, status10, ID11,status11,ID12,status12> 0 = Disabled 0 = Disabled 1 = Enabled

Depth of Field Enhance Serial Cmd: Default: Options:

<K456,mode> 2 = Medium 0 = Disabled 1 = Low 2 = Medium 3 = High

Code 39 Serial Cmd: Default: Options:

<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 1 = Enabled 0 = Disabled 1 = Enabled

Check Character Status (Code 39) Serial Cmd: <K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> Default: 0 = Disabled Options: 0 = Disabled 1 = Enabled Check Character Output Status (Code 39) Serial Cmd: Default: Options:

A-50

<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled

QX-870 Industrial Raster Scanner User Manual

Page 337

Appendices Large Intercharacter Gap (Code 39) Serial Cmd: Default: Options:

<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (Code 39) Serial Cmd: Default: Options:

<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length (Code 39) Serial Cmd: Default: Options:

<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 10 1 to 128

Full ASCII Set (Code 39) Serial Cmd: Default: Options:

<K470,status,check character status,check character output status,large intercharacter gap,fixed symbol length status,fixed symbol length,full ASCII set> 0 = Disabled 0 = Disabled 1 = Enabled

Codabar Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled

Start/Stop Match (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 1 = Enabled 0 = Disabled 1 = Enabled

QX-870 Industrial Raster Scanner User Manual

A-51

Page 338

Serial Commands Start/Stop Output (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 1 = Enabled 0 = Disabled 1 = Enabled

Large Intercharacter Gap (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled

Fixed Symbol Length Status (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled

Symbol Length (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 10 1 to 128

Check Character Type (Codabar) Serial Cmd: Default: Options:

A-52

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Mod 16 2 = NW7 (Mod 11) 3 = Both Mod 16 and NW7 (Mod 11)

QX-870 Industrial Raster Scanner User Manual

Page 339

Appendices Check Character Output (Codabar) Serial Cmd: Default: Options:

<K471,status,start/stop match,start/stop output,large intercharacter gap,fixed symbol length status,symbol length,check character type,check character output> 0 = Disabled 0 = Disabled 1 = Enabled

Interleaved 2 of 5 Serial Cmd: Default: Options:

<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 1 = Enabled 0 = Disabled 1 = Enabled

Check Character Status (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled

Check Character Output Status (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output status,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled

Symbol Length #1 (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 16 0 to 128

Symbol Length #2 (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 6 0 to 128

QX-870 Industrial Raster Scanner User Manual

A-53

Page 340

Serial Commands Guard Bar Status (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 0 = Disabled 0 = Disabled 1 = Enabled

Range Mode Status (Interleaved 2 of 5) Serial Cmd: Default: Options:

<K472,status,check character status,check character output,symbol length #1,symbol length #2,guard bar status,range mode status> 1 = Enabled 0 = Disabled 1 = Enabled

UPC/EAN Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 3 = Both Standard and Edge-to-Edge 0 = Disabled 1 = Standard 2 = Edge-to-Edge 3 = Both Standard and Edge-to-Edge

EAN Status Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 1 = Enabled 0 = Disabled 1 = Enabled

Supplementals Status (UPC/EAN) Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled 2 = Required

Separator Status (UPC/EAN) Serial Cmd: Default: Options:

A-54

<K473,UPC status,EAN status,supplementals status,separator status, separator character,supplemental type,format UPC-E as UPC-A> 0 = Disabled 0 = Disabled 1 = Enabled

QX-870 Industrial Raster Scanner User Manual