Page 311

Appendices

Concatenating Configuration Commands Commands can be concatenated (added together) in a single string. For example, <K145,1><K220,1><K450,1><A> enables LRC, sets End of Read Cycle mode to New Trigger, enables Narrow Quiet Zone, and resets the data buffers without saving the changes for power-on.

Serial Command Status Request To ensure that any command was received and accepted, send the Show Reader Status command: <?>. The status of a specific serial command can be requested by entering the command followed by a question mark. For example, send <K142?> to request the status of Postamble.

Entering Control Characters in Serial Commands To enter control characters within a serial command, hold down the Ctrl key while typing the desired character. Example: To enter a carriage return and line feed (^M^J), enter <K141,1,CNTL-m CNTL-j>

QX-870 Industrial Raster Scanner User Manual

A-25

Page 312

Serial Commands

Serial Configuration Commands The following serial commands can be entered through ESP’s Terminal to control QX-870 functions. Detailed descriptions of command parameters are available in Chapter 5, Scanner Parameters.

Communication RS-232 A RS-232 B RS-422 Ethernet Ethernet TCP Ports EtherNet/IP RS-232 A Data Type RS-232 B Data Type RS-422 Data Type Ethernet TCP Port 1 Data Type Ethernet TCP Port 2 Data Type EtherNet/IP Data Type Preamble Postamble Response Timeout LRC Status ACK/NAK Options Polling Mode Options Autoconfiguration Daisy Chain Protocol Selection External Data Routing Array Communication Modes

<K100,baud rate,parity,stop bits,data bits> <K101,status,baud rate,parity,stop bits,data bits> <K102,status,baud rate,parity,stop bits,data bits> <K126,status,IP address,subnet,gateway,IP address mode> <K127,TCP Port 1,TCP Port 2> <K129,status> <K130,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K131,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K132,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K133,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K134,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K136,symbol data output,extra symbol information,diagnostic output,external source processing mode> <K141,status,preamble> <K142,status,postamble> <K143,response timeout> <K145,status> <K147,RES,REQ,STX,ETX,ACK,NAK> <K148,RES,REQ,STX,ETX,ACK,NAK> <K150DAISY> <K160,protocol,address,protocol port> <K161,mode,destination port,ambles to source,echo to source,output at end of read cycle,output at ETX,output at timeout> <K162,mode,source,daisy chain i.d. status,daisy chain i.d.>

RS-232 A Baud Rate, RS-232 A Serial Cmd: Default: Options:

A-26

<K100,baud rate,parity,stop bits,data bits> 8 = 115.2K 0 = 600 1 = 1200 3 = 4800 4 = 9600 6 = 38.4K 7 = 57.6K 9 = 230K

2 = 2400 5 = 19.2K 8 = 115.2K

QX-870 Industrial Raster Scanner User Manual

Page 313

Appendices Parity, RS-232 A Serial Cmd: Default: Options:

<K100,baud rate,parity,stop bits,data bits> 0 = None 0 = None 1 = Even

2 = Odd

Stop Bits, RS-232 A Serial Cmd: Default: Options:

<K100,baud rate,parity,stop bits,data bits> 0 = One 0 = One 1 = Two

Data Bits, RS-232 A Serial Cmd: Default: Options:

<K100,baud rate,parity,stop bits,data bits> 1 = Eight 0 = Seven 1 = Eight

RS-232 B Status, RS-232 B Serial Cmd: Default: Options:

<K101,status,baud rate,parity,stop bits,data bits> 1 = Enabled 0 = Disabled 1 = Enabled

Baud Rate, RS-232 B Serial Cmd: Default: Options:

<K101,status,baud rate,parity,stop bits,data bits> 8 = 115.2K 0 = 600 1 = 1200 2 = 2400 3 = 4800 4 = 9600 5 = 19.2K 6 = 38.4K 7 = 57.6K 8 = 115.2K 9 = 230K

Parity, RS-232 B Serial Cmd: Default: Options:

<K101,status,baud rate,parity,stop bits,data bits> 0 = None 0 = None 1 = Even 2 = Odd

Stop Bits, RS-232 B Serial Cmd: Default: Options:

<K101,status,baud rate,parity,stop bits,data bits> 0 = One 0 = One 1 = Two

QX-870 Industrial Raster Scanner User Manual

A-27

Page 314

Serial Commands Data Bits, RS-232 B Serial Cmd: Default: Options:

<K101,status,baud rate,parity,stop bits,data bits> 1 = Eight 0 = Seven 1 = Eight

RS-422 Status, RS-422 Serial Cmd: Default: Options:

<K102,status,baud rate,parity,stop bits,data bits> 0 = Disabled 0 = Disabled 1 = Enabled

Baud Rate, RS-422 Serial Cmd: Default: Options:

<K102,status,baud rate,parity,stop bits,data bits> 8 = 115.2K 0 = 600 1 = 1200 2 = 2400 3 = 4800 4 = 9600 5 = 19.2K 6 = 38.4K 7 = 57.6K 8 = 115.2K 9 = 230K

Parity, RS-422 Serial Cmd: Default: Options:

<K102,status,baud rate,parity,stop bits,data bits> 0 = None 0 = None 1 = Even 2 = Odd

Stop Bits, RS-422 Serial Cmd: Default: Options:

<K102,status,baud rate,parity,stop bits,data bits> 0 = One 0 = One 1 = Two

Data Bits, RS-422 Serial Cmd: Default: Options:

<K102,status,baud rate,parity,stop bits,data bits> 1 = Eight 0 = Seven 1 = Eight

Ethernet Serial Cmd: Default: Options:

A-28

<K126,status,IP address,subnet,gateway,IP address mode> 1 = Enabled 0 = Disabled 1 = Enabled

QX-870 Industrial Raster Scanner User Manual

Page 315

Appendices IP Address Serial Cmd: Default: Options:

<K126,status,IP address,subnet,gateway,IP address mode> 192.168.0.100 0.0.0.0 – 255.255.255.255

Subnet Serial Cmd: Default: Options:

<K126,status,IP address,subnet,gateway,IP address mode> 255.255.0.0 0.0.0.0 – 255.255.255.255

Gateway Serial Cmd: Default: Options:

<K126,status,IP address,subnet,gateway,IP address mode> 0.0.0.0 0.0.0.0 – 255.255.255.255

IP Address Mode Serial Cmd: Default: Options:

<K126,status,IP address,subnet,gateway,IP address mode> 1 = DHCP 0 = Static 1 = DHCP

Ethernet TCP Ports TCP Port 1 Serial Cmd: Default: Options:

<K127,TCP Port 1,TCP Port 2> 2001 1024 – 65535

TCP Port 1 Serial Cmd: Default: Options:

<K127,TCP Port 1,TCP Port 2> 2003 1024 – 65535

EtherNet/IP Serial Cmd: Default: Options:

<K129,status> 1 = Enabled 0 = Disabled

1 = Enabled

RS-232 A Data Type Symbol Data Output, RS-232 A Serial Cmd: Default: Options:

<K130,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

QX-870 Industrial Raster Scanner User Manual

A-29

Page 316

Serial Commands Extra Symbol Information, RS-232 A Serial Cmd: Default: Options:

<K130,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Diagnostic Output, RS-232 A Serial Cmd: Default: Options:

<K130,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

External Source Processing Mode, RS-232 A Serial Cmd: Default: Options:

<K130,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data

RS-232 B Data Type Symbol Data Output, RS-232 B Serial Cmd: Default: Options:

<K131,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Extra Symbol Information, RS-232 B Serial Cmd: Default: Options:

<K131,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Diagnostic Output, RS-232 B Serial Cmd: Default: Options:

<K131,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

External Source Processing Mode, RS-232 B Serial Cmd: Default: Options: A-30

<K131,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data QX-870 Industrial Raster Scanner User Manual

Page 317

Appendices

RS-422 Data Type Symbol Data Output, RS-422 Serial Cmd: Default: Options:

<K132,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Extra Symbol Information, RS-422 Serial Cmd: Default: Options:

<K132,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Diagnostic Output, RS-422 Serial Cmd: Default: Options:

<K132,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

External Source Processing Mode, RS-422 Serial Cmd: Default: Options:

<K132,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data

QX-870 Industrial Raster Scanner User Manual

A-31

Page 318

Serial Commands

Ethernet TCP Port 1 Data Type Symbol Data Output, Ethernet TCP Port 1 Serial Cmd: Default: Options:

<K133,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Extra Symbol Information, Ethernet TCP Port 1 Serial Cmd: Default: Options:

<K133,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Diagnostic Output, Ethernet TCP Port 1 Serial Cmd: Default: Options:

<K133,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

External Source Processing Mode, Ethernet TCP Port 1 Serial Cmd: Default: Options:

<K133,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data

Ethernet TCP Port 2 Data Type Symbol Data Output, Ethernet TCP Port 2 Serial Cmd: Default: Options:

<K134,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Extra Symbol Information, Ethernet TCP Port 2 Serial Cmd: Default: Options:

A-32

<K134,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

QX-870 Industrial Raster Scanner User Manual

Page 319

Appendices Diagnostic Output, Ethernet TCP Port 2 Serial Cmd: Default: Options:

<K134,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

External Source Processing Mode, Ethernet TCP Port 2 Serial Cmd: Default: Options:

<K134,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data

EtherNet/IP Data Type Symbol Data Output, EtherNet/IP Serial Cmd: Default: Options:

<K136,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Extra Symbol Information, EtherNet/IP Serial Cmd: Default: Options:

<K136,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

Diagnostic Output, EtherNet/IP Serial Cmd: Default: Options:

<K136,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Enabled 0 = Disabled 1 = Enabled

External Source Processing Mode, EtherNet/IP Serial Cmd: Default: Options:

<K136,symbol data output,extra symbol information,diagnostic output, external source processing mode> 1 = Command 0 = Disabled 1 = Command 2 = Data

Preamble Preamble Status Serial Cmd: Default: Options:

<K141,status,preamble character(s)> 0 = Disabled 0 = Disabled 1 = Enabled

QX-870 Industrial Raster Scanner User Manual

A-33

Page 320

Serial Commands Preamble Characters Serial Cmd: Default: Options:

<K141,status,preamble character(s)> CR (0x0D) 1 – 4 ASCII characters

Postamble Postamble Status Serial Cmd: Default: Options:

<K142,status,postamble character(s)> 1 = Enabled 0 = Disabled 1 = Enabled

Postamble Characters Serial Cmd: Default: Options:

<K142,status,postamble character(s)> CR LF (0x0D 0x0A) 1 – 4 ASCII characters

Response Timeout Serial Cmd: Default: Options:

<K143,response timeout> 5 (x10 ms = 50) 0 to 255 (x10 ms)

LRC Status Serial Cmd: Default: Options:

<K145,status> 0 = Disabled 0 = Disabled

1 = Enabled

ACK/NAK Options Serial Cmd:

<K147,RES,REQ,STX,ETX,ACK,NAK>

RES-NAK Defaults RES: (Reset) REQ: (Request) STX: (Start of Text) ETX: (End of Text) ACK: (Acknowledge) NAK: (Negative Acknowledge)

A-34

00 (disabled) 00 (disabled) 00 (disabled) 00 (disabled) 06 15

QX-870 Industrial Raster Scanner User Manual