Page 11

1 Quick Start Contents Step 1 Check Hardware................................................................................................................ 1-2 Step 2 Connect the System .......................................................................................................... 1-3 Step 3 Position Scanner and Symbol ........................................................................................... 1-4 Step 4 Install ESP ......................................................................................................................... 1-5 Step 5 Select Model...................................................................................................................... 1-6 Step 6 Connect ............................................................................................................................. 1-7 Step 7 Test Read Rate .............................................................................................................. 1-10 Step 8 Configure the Scanner.................................................................................................... 1-11 Step 9 Save Changes in ESP .................................................................................................... 1-12

This section explains how to set up and test the QX-870 quickly using ESP (Easy Setup Program). Detailed setup information for installing the scanner into an application can be found in subsequent sections.

QX-870 Industrial Raster Scanner User Manual

1-1

Page 12

Check Hardware

Step 1, Check Hardware Item 1 2 3 4 5 6 7 8

Description QX-870 Industrial Raster Scanner QX-1 Interface Device QX Cordset, Common, M12 12-pin Socket to M12 12-pin Plug, 1 m QX Cordset, Host, Serial, M12 12-pin Plug to DB9 Socket, 1 m QX Cordset, Host, Serial, M12 12-pin Socket to DB9 Socket, 1 m QX Power Supply, 100-240VAC, +24VDC, M12 12-pin Socket QX Cordset, Host, Ethernet, M12 8-pin Plug to RJ45, 1 m QX Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m

Part Number FIS-0870-XXXXG 98-000103-02 61-000162-02 61-000152-02 61-000153-02 97-000012-01 61-000160-02 99-000020-02

Note: Additional cordsets and accessories are available in the Microscan Product Pricing Catalog.

Important: This product is intended to be supplied by a Listed power supply marked “Class 2” or “LPS” and rated from 10 to 28 VDC, 9.0 Watts. Note: The QX-870 does not require an Ethernet crossover cordset, because the scanner itself performs automatic internal crossover (transmit-to-receive switching). Microscan offers a standard straight-through (un-crossed) Ethernet cordset (61-000160-02). Important: Do not attempt to power more than four scanners with a single power supply in a daisy chain configuration. Add a QX-1 and one power supply for every four additional scanners in the daisy chain. 1 1

5

3

7

2

4 or 7 6

6

8

Standalone (with QX-1)

8

Standalone (without QX-1) Hardware Required

Caution: Be sure that all connections are secure BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.

1-2

QX-870 Industrial Raster Scanner User Manual

Page 13

Quick Start

Step 2, Connect the System Important: If you are connecting Ultra-Lock cordsets to the QX-870 and QX-1, align the pins first and then push the connector into place. Do not twist the connectors, as this will bend the pins. Important: Do not attempt to power more than four scanners with a single power supply in a daisy chain configuration. Add a QX-1 and one power supply for every four additional scanner in the daisy chain. Note: The configuration instructions below are for simple, direct connections to an RS-232 or Ethernet host. The QX-1 can be added to RS-232 or Ethernet configurations in which greater flexibility and complexity are required. The first diagram in Step 1 shows a standalone configuration that includes the QX-1.

RS-232 Standalone (without QX-1) • Connect the Serial Communication Cable from “B” on the QX-870 to the host. • Connect the photo sensor (if required) to “T” on the QX-870. • Connect the power supply to “P/M” on the QX-870. • Plug in the power supply.

Ethernet Standalone (without QX-1) Important: Configure Ethernet-enabled readers off-line and then connect to network when ready for dynamic use. Note: The QX-870 does not require an Ethernet crossover cordset, because the scanner itself performs automatic internal crossover (transmit-to-receive switching). Microscan offers a standard straight-through (un-crossed) Ethernet cordset (61-000160-02). • Connect the Ethernet Communication Cable from “B” on the QX-870 to the host network. • Connect the power supply to “P/M” on the QX-870. • Plug in the power supply. 1 1

5

3

7

2 4 or 7 8

6

8

6

Standalone (with QX-1) QX-870 Industrial Raster Scanner User Manual

Standalone (without QX-1) 1-3

Page 14

Position Scanner and Symbol

Step 3, Position Scanner and Symbol • Place a test symbol in a location with as little ambient light as possible. • Position the scanner at the focal distance used in the application. • Align the test symbol with the scanner’s field of view. • Tip the scanner relative to the test symbol to avoid glare from specular reflection. Bar code label axis Skew

Symbol

Tilt axis Tilt

Scanner

Scanner Scan line

1-4

Maximum skew, tilt, and pitch: ±30°

Pitch Pitch axis

QX-870 Industrial Raster Scanner User Manual

Page 15

Quick Start

Step 4, Install ESP ESP Software can be found on the Microscan Tools Drive that is packaged with the QX-870. 1. Follow the prompts to install ESP from the Tools Drive. 2. Click on the ESP icon to run the program.

Note: ESP can also be installed from the Download Center at www.microscan.com.

Minimum System Requirements • 233 MHz Pentium PC • Windows 8, 7, Vista, or XP operating system (32-bit or 64-bit) • Internet Explorer 6.0 or higher • 128 MB RAM or greater • 160 MB free disk space • 800 x 600 256 color display (1024 x 768 32-bit color recommended)

QX-870 Industrial Raster Scanner User Manual

1-5

Page 16

Select Model

Step 5, Select Model When ESP is opened, the following menu will appear:

1. Click the button showing the QX-870. 2. Click OK. Note: The QX-870 can also be selected by double-clicking the button showing the QX-870. 3. Click Yes when this dialog appears:

Note: To select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar. 1-6

QX-870 Industrial Raster Scanner User Manual

Page 17

Quick Start

Step 6, Connect Connection Wizard To connect using the Connection Wizard: • Click Connect on the menu toolbar, and then select Connection Wizard. • Select RS-232 or Ethernet to activate the appropriate display. • Configure RS-232 or Ethernet settings as required by the application, and click Connect.

RS-232 Connection Wizard

Ethernet Connection Wizard

• When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible:

Important: The scanner is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the scanner’s field of view while attempting to connect.

QX-870 Industrial Raster Scanner User Manual

1-7

Page 18

Connect (cont.)

Step 6, Connect (cont.) Ethernet TCP/IP Once the QX-870 is connected, incoming symbol data can be displayed in the Terminal, as shown below.

1-8

QX-870 Industrial Raster Scanner User Manual

Page 19

Quick Start

Step 7, Test Read Rate Read Rate indicates the number or percentage of successful decodes per second achieved by the scanner. 1. Click the Test button in ESP’s EZ Mode to start the Read Rate test. Symbol data and read rate percentage information should appear in the Symbol Information table in the bottom portion of the view. The Read Rate LEDs on the side of the QX-870 will indicate the percentage of successful decodes per second. 2. Click Stop to end the Read Rate test. Note: Read Rate can also be tested using the Read Rate interface in Utilities.

QX-870 Industrial Raster Scanner User Manual

1-9

Page 20

Configure the Scanner

Step 8, Configure the Scanner Click the App Mode button to make configuration changes to the scanner.

The following modes are accessible by clicking the buttons at the top of the screen:

• Click the EZ Mode button to return to EZ Mode. • Click the Autoconnect button to establish communication. • Click the Send/Recv button to send or receive commands. • Click the Switch Model button to open the model menu, or to return to a previous model. • Click the Parameters button to show the tabbed tree control views. • Click the Setup button to show the tabbed interface views. • Click the Terminal button to display decoded symbol data and to send serial commands. • Click the Utilities button to access Read Rate, Counters, Device Control, Differences from Default, Master Database, Digital Bar Code, and Firmware. For further details, see Microscan ESP Help in the dropdown Help menu.

1-10

QX-870 Industrial Raster Scanner User Manual