Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 19 of 43

QX-870 Industrial Raster Scanner User Manual, pages 181 to 190

Pages 181 to 190 of 426

The original document is the PDF (7.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan QX-870

Page 181

Scanner Parameters

Green Flash Duration Provides visual verification that a good read has occurred. When a good read occurs, the green LEDs will illuminate and stay on for the time set in the Green Flash Duration value.

Beeper An audible verification that either a good read or a No Read has occurred. A beep is emitted after each good read or No Read. Note: The beeper will also sound at any of the following times: • When the scanner is defaulted. • When a Send and Save command is sent from ESP. • At the conclusion of an Auto Calibration procedure. • When a <Z>, <Zp>, <Zrd>, or <K701,,1> command is sent from ESP’s Terminal.

QX-870 Industrial Raster Scanner User Manual

5-115

Page 182

I/O Parameters

Serial Verification Allows the user to verify configuration command status.

Serial Command Echo Status This command is useful in removing any doubt about the scanner’s interpretation of any configuration command. For example, if the current preamble is “SOM” and <K701,1,START> is entered, the scanner will echo back <K701,SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore, it is rejected and the existing “SOM” message is echoed back and remains the preamble message. When enabled, a configuration command received from the host is echoed back to the host with the resultant settings. Host Scanner If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change.

Serial Command Beep Status Used to audibly verify the acceptance and validity of a command. Causes the scanner to beep once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the scanner beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response.

5-116

QX-870 Industrial Raster Scanner User Manual

Page 183

Scanner Parameters

Control / Hex Output Useful for viewing settings with binary characters when using serial commands on a terminal. Determines the response to a Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a non-displayable character. For example, a carriage return will be shown as: ^M.

QX-870 Industrial Raster Scanner User Manual

5-117

Page 184

I/O Parameters

EZ Button

Serves as a master switch to enable/disable the EZ Button status.

The EZ Button has four positions: Single Beep, Two Beeps, Three Beeps, and Four Beeps, selectable by the length of time the button is held down, and indicated by one, two, three, and four beeps in succession. Each position can be programmed for any of eight EZ Button Modes.

5-118

QX-870 Industrial Raster Scanner User Manual

Page 185

Scanner Parameters

EZ Button Status

Disabled When set to Disabled, the EZ Button does not function.

Enabled When selected, the EZ Button is enabled and the function of each button position is selected by the EZ Button Modes command.

Trigger When selected, the EZ Button acts as a trigger for the scanner to start and end read cycles. All other button operations are inactive. In External Level: In External Edge:

The read cycle endures for as long as the EZ Button is pressed, unless a timeout occurs and End of Read Cycle Mode is set to Timeout. As with External Level, External Edge allows a read cycle to be initiated by pressing the EZ Button, but unlike External Level, the read cycle ends with a good read output, a timeout, or a new trigger.

Unlatch Outputs In this configuration, the EZ Button will unlatch any logic outputs that have been latched.

Parameter Switch The parameter switch toggles between custom defaults and power-on settings. The condition is the same as that achieved by sending the <Arc> and <Arp> commands consecutively.

Default on Power-On When enabled, if the EZ Button is held down on power-on, the scanner will default to customer defaults and save for power-on. This is the same as sending a <Zrc> command from ESP’s Terminal.

QX-870 Industrial Raster Scanner User Manual

5-119

Page 186

I/O Parameters

EZ Button Modes Useful for performing multiple, repetitive tasks at the work site. Allows the user to program each of the EZ Button’s 4 positions from a selection of 8 modes.

Single Beep Hold down button until a single beep is heard (and the 20% LED illuminates).

Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibration Calibration is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Auto Framing Auto Framing is initiated when this button position is selected. To cancel Auto Framing, quickly press and release the EZ Button. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Sleep Mode When Sleep Mode is selected, the scanner will shut the motor and laser off when this button position is selected. To cancel Sleep Mode, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button. 5-120

QX-870 Industrial Raster Scanner User Manual

Page 187

Scanner Parameters

Two Beeps Hold down button until two quick beeps are heard (and the 20% and 40% LEDs illuminate.)

Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibration Calibration is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Auto Framing Auto Framing is initiated when this button position is selected. To cancel Auto Framing, quickly press and release the EZ Button. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Sleep Mode When Sleep Mode is selected, the scanner will shut the motor and laser off when this button position is selected. To cancel Sleep Mode, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the scanner can accept configuration commands from symbols. To cancel Bar Code Configuration, quickly press and release the EZ Button.

QX-870 Industrial Raster Scanner User Manual

5-121

Page 188

I/O Parameters

Three Beeps Hold down button until three quick beeps are heard (and the 20%, 40%, and 60% LEDs illuminate).

Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibration Calibration is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Auto Framing Auto Framing is initiated when this button position is selected. To cancel Auto Framing, quickly press and release the EZ Button. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Sleep Mode When Sleep Mode is selected, the scanner will shut the motor and laser off when this button position is selected. To cancel Sleep Mode, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.

5-122

QX-870 Industrial Raster Scanner User Manual

Page 189

Scanner Parameters

Four Beeps Hold down button until four quick beeps are heard (and the 20%, 40%, 60%, and 80% LEDs illuminate).

Disabled When set to Disabled, the associated button position will have no function associated with it, and the position will be skipped over. Read Rate Read Rate is initiated when the associated button position is selected. Read Rate will perform decodes/second and is the same as sending a <C> from ESP’s Terminal. To exit Read Rate, quickly press and release the EZ Button. Calibration Calibration is initiated when the associated button position is selected. To cancel Calibration, quickly press and release the EZ Button. Save for Power-On All scanner settings will be saved to non-volatile memory to be recalled on power-on whenever the associated button position is selected. This is the same as sending a <Z> from ESP’s Terminal. Auto Framing Auto Framing is initiated when this button position is selected. To cancel Auto Framing, quickly press and release the EZ Button. Load New Master Functions in the same way as New Master Pin input whenever the associated button position is selected. Sleep Mode When Sleep Mode is selected, the scanner will shut the motor and laser off when this button position is selected. To cancel Sleep Mode, quickly press and release the EZ Button. Bar Code Configuration Enables Bar Code Configuration Mode whenever the associated button position is selected. When enabled, the scanner can accept configuration commands from symbols. To disable, quickly press and release the EZ Button.

QX-870 Industrial Raster Scanner User Manual

5-123

Page 190

I/O Parameters

Auto Framing Options When Enabled, Laser Framing is performed when the Auto Framing button beep position is selected (Single Beep, Two Beeps, Three Beeps, or Four Beeps).

5-124

QX-870 Industrial Raster Scanner User Manual