Two-page Microscan quick start guide for the QX-870 Industrial Raster Scanner. It lists the hardware for a basic system and walks through connecting to an RS-232 or Ethernet host, positioning the scanner, installing the ESP software, connecting, testing the read rate and saving settings.

Device
QX-870 Industrial Raster Scanner p. 1
Host interfaces
RS-232 serial or Ethernet, through port B p. 1
Ports
B for the host cable, T for a photo sensor, P/M for the power supply p. 1
Power supply
QX Power Supply, 100-240VAC, +24VDC, M12 12-pin socket p. 1
Host cordsets
M12 12-pin to DB9 socket for serial; M12 8-pin plug (screw-on) to RJ45 for Ethernet; 1 m p. 1
Photo sensor
QX Photo Sensor, M12 4-pin plug, NPN, Dark On, 2 m p. 1
Interface device
Optional QX-1 Interface Device for more complex RS-232 or Ethernet setups p. 1
Mounting angle
Maximum skew, tilt and pitch ±30° p. 1
Software
ESP, on the Microscan Tools Drive packed with the scanner or from the Download Center p. 1
PC for ESP
233 MHz Pentium; Windows 8, 7, Vista or XP; 128 MB RAM; 160 MB free disk; 800 x 600 display p. 1
Default read mode
Continuous Read Mode p. 2
Read rate LEDs
LEDs on the side show the percentage of successful decodes per second p. 2

What this manual walks you through

  • Connecting a standalone scanner to an RS-232 host p. 1
  • Connecting a standalone scanner to an Ethernet network p. 1
  • Positioning the scanner against a test symbol to avoid glare p. 1
  • Installing ESP and selecting the QX-870 model p. 1
  • Connecting to the scanner with the ESP Connection Wizard p. 2
  • Testing the read rate in EZ Mode p. 2
  • Changing and saving settings in App Mode p. 2

Good to know

  • Align the pins of Ultra-Lock cordsets before pushing them in; twisting bends the pins. p. 1
  • Power no more than four scanners from one power supply in a daisy chain; add a QX-1 and a supply for every four more. p. 1
  • Make all connections before applying power, and power down before disconnecting any cable. p. 1
  • Configure Ethernet-enabled scanners off-line, then connect them to the network. p. 1
  • Keep decodable symbols out of the field of view while connecting. p. 2

Questions this manual answers

What power supply does the Microscan QX-870 use?

The QX Power Supply, 100-240VAC in, +24VDC out, with an M12 12-pin socket, connected to the P/M port. p. 1

How many QX-870 scanners can share one power supply?

No more than four in a daisy chain; add a QX-1 and one power supply for every four more. p. 1

What software configures the QX-870?

Microscan ESP, from the Tools Drive packed with the scanner or the Microscan Download Center. p. 1

How do I test the QX-870 read rate?

Click Test in ESP's EZ Mode; the read rate shows in the Symbol Information table and on the scanner's Read Rate LEDs. Click Stop to end. p. 2

The file

Size and text

Pages2
PDF642 KB
TextText from the PDF itself.

Every page · 2

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Microscan QX-870 Quick Start

The text of page 1, from the PDF itself

Quick Start Guide

Step 1, Check Hardware

QX-870 Industrial Raster Scanner

Step 2, Connect the System Important: If you are connecting Ultra-Lock cordsets to the QX-870 and QX-1, align the pins first and then push the connector into place. Do not twist the connectors, as this will bend the pins.

1 1

5

Important: Do not attempt to power more than four scanners with a single power supply in a daisy chain configuration. Add a QX-1 and one power supply for every four additional scanner in the daisy chain.

3 7 62 684 or 7 8Standalone (with QX-1)

Standalone (without QX-1)

Hardware Required Caution: Be sure that all connections are secure BEFORE applying power. Always power down BEFORE disconnecting any cables. Item Description 1 QX-870 Industrial Raster Scanner 2 QX-1 Interface Device 3 QX Cordset, Common, M12 12-pin Socket to M12 12-pin Plug, 1 m 4 QX Cordset, Host, Serial, M12 12-pin Plug to DB9 Socket, 1 m 5 QX Cordset, Host, Serial, M12 12-pin Socket to DB9 Socket, 1 m 6 QX Power Supply, 100-240VAC, +24VDC, M12 12-pin Socket 7 QX Cordset, Host, Ethernet, M12 8-pin Plug (Screw-On) to RJ45, 1 m 8 QX Photo Sensor, M12 4-pin Plug, NPN, Dark On, 2 m

Part Number FIS-0870-XXXXG 98-000103-02 61-000162-02 61-000152-02 61-000153-02 97-000012-01 61-000160-02 99-000020-02

Note: The configuration instructions below are for simple, direct connections to an RS-232 or Ethernet host. The QX-1 can be added to RS-232 or Ethernet configurations in which greater flexibility and complexity are required. The first diagram in Step 1 shows a standalone configuration that includes the QX-1.

RS-232 Standalone (without QX-1) 1. Connect the Serial Communication Cable from “B” on the QX-870 to the host. 2. Connect the photo sensor (if required) to “T” on the QX-870. 3. Connect the power supply to “P/M” on the QX-870. 4. Plug in the power supply.

Ethernet Standalone (without QX-1) Important: Configure Ethernet-enabled scanners off-line and then connect to the network when ready for dynamic use. 1. Connect the Ethernet Communication Cable from “B” on the QX-870 to the host network. 2. Connect the power supply to “P/M” on the QX-870. 3. Plug in the power supply.

Note: Additional cordsets and accessories are available in the Microscan Product Pricing Catalog.

P/N 83-110870-04 Rev A

Step 3, Position Scanner

Step 4, Install ESP

1. Place a test symbol in a location with as little ambient light as possible. 2. Position the scanner at the focal distance used in your application. 3. Align the test symbol with the scanner’s field of view. 4. Tip the scanner relative to the test symbol to avoid glare from specular reflection.

ESP Software can be found on the Microscan Tools Drive that is packaged with the QX-870. 1. Follow the prompts to install ESP from the Tools Drive. 2. Click on the ESP icon to run the program.

Step 5, Select Model When you start ESP, the model menu will appear:

Note: ESP can also be installed from the Download Center at www.microscan.com. Maximum skew, tilt, and pitch: ±30°

Refer to the QX-870 Industrial Raster Scanner User Manual for detailed information about using ESP to configure the QX-870.

Minimum System Requirements

233 MHz Pentium PC Windows 8, 7, Vista, or XP operating system (32-bit or 64-bit) Internet Explorer 6.0 or higher 128 MB RAM or greater 160 MB free disk space 800 x 600 256 color display (1024 x 768 32-bit color recommended)

1. Click the button showing the QX-870. 2. Click OK. Note: You can also simply double-click the button showing your scanner to make your selection. 3. Click Yes when this dialog appears:

Note: If you need to select another model later, click the Switch Model button near the top of the screen or use Model > New Model in the menu toolbar. Copyright ©2015 Microscan Systems, Inc.

Page 2 of Microscan QX-870 Quick Start

The text of page 2, from the PDF itself

Step 6, Connect

Step 6, Connect (cont.)

Step 6, Connect (cont.)

RS-232

Ethernet TCP/IP

Ethernet TCP/IP (cont.)

To connect using the Connection Wizard:

  • Click Connect on the menu toolbar, and then select Connection Wizard.
  • Select RS-232.
  • Configure RS-232 settings as required by the application, and click Connect.

To connect using the Connection Wizard:

  • Click Connect on the menu toolbar, and then select Connection Wizard.
  • Select Ethernet.
  • Configure Ethernet settings as required by the application, and click Connect.

When the QX-870 is connected, incoming symbol data can be displayed in the Terminal, as shown below.

  • When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible:
  • When a connection is established, the green indicator in the status bar at the bottom right of the screen will be visible. Important: The scanner is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the scanner’s field of view while attempting to connect.

Important: The scanner is in Continuous Read Mode by default. For best connection results, be sure that no decodable symbols are within the scanner’s field of view while attempting to connect.

Step 7, Test Read Rate Read Rate indicates the number or percentage of successful decodes per second achieved by the scanner. 1. Click the Test button in ESP’s EZ Mode to start the Read Rate test. Symbol data and read rate percentage information should appear in the Symbol Information table. The Read Rate LEDs on the side of the QX-870 will indicate the percentage of successful decodes per second. 2. Click Stop to end the Read Rate test. Note: Read Rate can also be tested using the Read Rate interface in Utilities.

Step 8, Configure and Save Click the App Mode button to make configuration changes to the scanner.

The following modes are accessible by clicking the buttons at the top of the screen:

Refer to the QX-870 Industrial Raster Scanner User Manual for information about how to test read rate using serial commands or the scanner’s EZ button.

Copyright ©2015 Microscan Systems, Inc.

Click the EZ Mode button to return to EZ Mode. Click the Autoconnect button to establish communications. Click the Send/Recv button to send or receive commands. Click the Switch Model button to open the model menu, or to return to the previous model. Click the Parameters button to show the tabbed tree control views. Click the Setup button to show the tabbed interface views. Click the Terminal button to display decoded symbol data and to send serial commands. Click the Utilities button to access Read Rate, Counters, Device Control, Differences from Default, Master Database, Digital Bar Code, and Firmware. For further details, see ESP Help in the Help dropdown menu.