The text of a manual · part 42 of 43
QX-830 Compact Industrial Scanner User Manual, pages 411 to 420
Pages 411 to 420 of 422
The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX-830
Page 411
Appendices • Enter the name of the device used in the PLC program and the IP address of the camera.
• After the new device has been added to the project, the default assembly data will be the small size. You can change it to large by double-clicking the camera menu item in the tree control and clicking the Change button on the dialog.
QX-830 Compact Industrial Scanner User Manual
A-123
Page 412
Allen-Bradley Version 20 PLC Setup • Select the large assembly size and click the OK button when done.
A-124
QX-830 Compact Industrial Scanner User Manual
Page 413
Appendices
Appendix M, EIPScan Setup This procedure is for the EIPScan simulation tool published by Pyramid Solutions. 1. Right-click on EIPScan Test Tool and select Add Device.
2. Set the IP Address to match the QX-830.
QX-830 Compact Industrial Scanner User Manual
A-125
Page 414
EIPScan Setup The QX-830 will show up in the main window.
3. Right-click on QX-830 and select Add Class1 Connection.
A-126
QX-830 Compact Industrial Scanner User Manual
Page 415
Appendices 4. When the Add Class1 Connection dialog appears, select Data Size. 5. Populate Originator->Target (OUT) with 12, and Target->Originator (Big IN) with 176.
Alternately, Target->Originator could be set to 84 for the Small IN assembly. 6. Select Rate and set packet rate to 20 milliseconds in both directions.
QX-830 Compact Industrial Scanner User Manual
A-127
Page 416
EIPScan Setup 7. Select Destination. 8. Populate Originator->Target (OUT) with 198, and Target->Originator (Big IN) with 101.
Alternately, Target->Originator could be set to 100 for the Small IN assembly. 9. Click OK and the IO data windows will appear in the main area. 10. In the I/O menu, select Run mode so that there is a check mark next to it.
A-128
QX-830 Compact Industrial Scanner User Manual
Page 417
Appendices EIPScan begins polling the unit, and displays the content of the IN (blue) and OUT (green) assemblies.
The order of data displayed in each assembly block corresponds to the object model documentation. For a quick test, we can simulate the PLC setting the User Tag, with the QX-830 echoing it back. 11. Click on the first byte (User Tag) in the green area (OUT).
QX-830 Compact Industrial Scanner User Manual
A-129
Page 418
EIPScan Setup 12. Change the first byte to non-zero. The first byte (User Tag echo) in the blue area (IN) will change to the same value.
All bytes in the green OUT area will be echoed back in the blue IN area, at the same location relative to the beginning of the assemblies. Each byte, and bit, has a unique purpose. Please consult the object model for a description. Note that all data is displayed in little-endian order.
A-130
QX-830 Compact Industrial Scanner User Manual
Page 419
Appendices
Appendix N, Interface Standards Interface Standards, established by the Electronic Industries Association (EIA), specify such things as the signaling voltage levels, maximum cable lengths, and number of drivers. In the QX-830, selection of interface is made by pin assignment and, in the case of host communication, by software switching between RS-232 and RS-422/RS-485.
RS-232 RS-232 defines an interface between two devices such as, for example, the scanner and host. It differs from the other interfaces by dedicating individual pins to specific functions and by requiring both devices to share a common ground line. Since both device chassis are connected to a common ground, a ground loop potential and the possibility of noise interference exists. Therefore cable lengths are limited to a maximum of 50 feet (19.7m). Despite being the most limited, this interface is used frequently because of the large installed base of RS-232 equipment.
RS-422/RS-485 RS-422, unlike RS-232, measures signals deferentially; that is, the receiver looks at the potentials between the two receive (or transmit) wires rather than the potential between signal and ground. As a result, cables, if shielded, can be up to 4000 feet (1219m) in length. Like RS-232, RS-422 communication is designed for only two devices on a single line and must have a common ground. It can be used wherever RS-232 is used.
Ethernet TCP/IP and EtherNet/IP TCP/IP and EtherNet/IP protocols are supported over Ethernet. A 6-byte hardware address is used, which is divided into a 3-byte vendor ID and a 3-byte vendor-defined field. Ethernet-enabled device manufacturers are assigned a unique vendor ID, and are then responsible for insuring that all of their devices have unique addresses in the last 3 bytes.
QX-830 Compact Industrial Scanner User Manual
A-131
Page 420
Glossary of Terms
Appendix O, Glossary of Terms AGC, See Automatic Gain Control. Analog, A smooth, continuous voltage or current signal or function whose magnitude (value) is the information. Automatic Gain Control (AGC), Adjustment to signal strength that seeks to maintain a constant level regardless of the distance between a scanner and symbol. Baud Rate, The number of discrete signal events per second; bits per second. Check Character, A Modulus 43 or Modulus 10 character that is added to encoded symbol data for additional data integrity. Connector, A plug or socket on a device or cable providing in/out connectivity for various circuits and pins. Concentrator, Intermediary device that relays data from scanners to a host and commands from the host to the scanners or other devices. Counter, Memory space allocated to keep track of scanner events. Daisy Chain, Linkage of primary and secondary scanners allowing data to be sent to the host. Decode, A good read. The successful interpretation and output of the information encoded in a symbol. Default, Restores non-volatile or flash memory settings, initializes serial commands, and resets all counters. Delimited, A delimited command or field is bracketed by predefined characters. Decode Rate, The number of good reads per second ahieved by a scanner. Discrete I/O, Inputs and outputs characterized by discrete signal transitions from one voltage level to another so that digital switching can occur. End of Read Cycle, The time or condition at which the scanner stops expecting symbol information to decode. External Edge, Allows a read cycle to be initiated by a trigger signal from an object detector when it detects the appearance of an object. The read cycle ends with a good read, a timeout, or a new trigger. External Level, Allows a read cycle to be initiated by a trigger signal from a photo sensor. The read cycle ends when the object moves out of the detector’s range. Firmware, Software hard-coded in non-volatile memory and closely tied to specific pieces of hardware. Fixed Symbol Length, Increases data integrity by ensuring that only one symbol length will be accepted. Full Duplex, A communication system in which signals can travel simultaneously between devices. Gain, Optimal signal strength. Good Read, A decode. The successful scanning and decoding of the information encoded in a symbol.
A-132
QX-830 Compact Industrial Scanner User Manual