Page 401

Appendices 16. In this example, the small assembly set has been kept:

In this example, the big assembly set has been kept:

For the remainder of this document, the big assembly set is demonstrated. The system is now configured enough to test communication with QX-830. QX-830 Compact Industrial Scanner User Manual

A-113

Page 402

Allen-Bradley Version 16 PLC Setup 17. Select the control button next to “Offline”, and select “Download”:

18. Once the program has downloaded, make sure the PLC is in Run Mode:

A-114

QX-830 Compact Industrial Scanner User Manual

Page 403

Appendices 19. To open the Program Tags, right-click on “Program Tags” and select “Monitor Tags”:

20. Expand the “QXHawk_IO_big_pt” so that the .IN and .OUT structures and values are visible:

QX-830 Compact Industrial Scanner User Manual

A-115

Page 404

Allen-Bradley Version 16 PLC Setup 21. Change the “.OUT.usertag” to non-zero:

A-116

QX-830 Compact Industrial Scanner User Manual

Page 405

Appendices The “.IN.usertag_echo” will change to match the same value as the “.OUT.usertag”:

This confirms that two-way communication with QX-830 is successful. It is left to the programmer to move or modify the CPS instructions in the Main Program according to the application’s requirements. Operation of the data fields within the assemblies is described in the object model documentation.

QX-830 Compact Industrial Scanner User Manual

A-117

Page 406

Allen-Bradley Version 20 PLC Setup

Appendix L, Allen-Bradley Version 20 PLC Setup • To add a new EDS file to RSLogix 5000 Version 20 select the EDS Hardware Installation Tool from the menu item under Tools.

• Click the Next button.

A-118

QX-830 Compact Industrial Scanner User Manual

Page 407

Appendices • Make sure the Register an EDS file(s) radio button is selected, then click Next.

• Click the Browse button to locate the new EDS file on your PC. Then click Next.

QX-830 Compact Industrial Scanner User Manual

A-119

Page 408

Allen-Bradley Version 20 PLC Setup • Click the Next button.

• Click the Next button.

A-120

QX-830 Compact Industrial Scanner User Manual

Page 409

Appendices • Click the Next button.

• Click the Finish button.

QX-830 Compact Industrial Scanner User Manual

A-121

Page 410

Allen-Bradley Version 20 PLC Setup • Now the EDS file has been loaded into RSLogix’s database. Right-click the Ethernet menu item and select New Module.

• To find your camera in the list, type fis and the dialog will show only devices with the letters “fis” in the name. Either double-click the camera you want or highlight it and click the Create button.

A-122