Page 271
Utilities
Request Master Symbol Data Returns master symbol data for any enabled master symbols from 1 to 10. 1. Click the Utilities button and the Master Database tab. 2. Click the Receive Reader’s Database button.
Read Next Symbol as Master Symbol After the size of the database is set, the scanner can read the next symbol as the master symbol for any given master symbol number. <Gmaster symbol number> To store the next symbol decoded as master symbol # 1, send: <G> or <G1>. To store the next symbol decoded as the master symbol for any other master symbol database number, send: <Gmaster symbol number [1-10]>. For example, <G5> will cause the next symbol read to be entered as master symbol # 5. In the Master Database tab, 1. Select the master symbol index number in which new symbol data will be stored. 2. Click the Read Symbol into Selected Index button.
Caution: If an index with existing data is selected, that data will be overwritten by the new decoded data when this command is used.
QX-830 Compact Industrial Scanner User Manual
7-13
Page 272
Master Database
Request New Master Status Informs the user when a new master symbol is pending and which position it is in. Returns the position in the master symbol database that will be loaded on the next read. Send the <NEWM> command from ESP’s Terminal. The scanner returns: <NEWM/next master to load> Once a symbol has been read and loaded, the status will be cleared and the response will be <NEWM/0>.
7-14
QX-830 Compact Industrial Scanner User Manual
Page 273
Utilities
Delete Master Symbol Data Master symbol data can be deleted using ESP. 1. Click the Utilities button to access the master symbol. 2. Click the Master Database tab and double-click the symbol number to be deleted. 3. Delete text and click OK.
QX-830 Compact Industrial Scanner User Manual
7-15
Page 274
Digital Bar Code
Digital Bar Code Click the Utilities button and then the Digital Bar Code tab to display the Digital Bar Code view. Click the Digital Bar Code tab and the Start button to view a digitized representation of the symbol in front of the scanner.
This routine is useful for conveying a sense of the symbol’s readability and graphically indicating bad or unreadable portions of symbols or extraneous “noise”. A green waveform indicates a decoded symbol; a red waveform indicates an undecoded symbol or other object. The red triangles represent the width of the scan beam relative to the symbol. The upward pointing arrows indicate the symbol’s quiet zone.
Zoom In / Zoom Out Increase the zoom level by sliding the Zoom lever to the right. It may be necessary to scroll right or left to view the symbol’s waveform in its entirety.
7-16
QX-830 Compact Industrial Scanner User Manual
Page 275
Utilities
Firmware Click the Utilities button and then the Firmware tab to display the Firmware view.
Firmware Update Firmware Update is used to download application code to the scanner. Application code versions are specific to the scanner. Consult with a sales representative before downloading application code. If needed, application/boot code in the form of a *.mot file can be requested. To download application code: 1. First, be sure that the scanner is connected to the host computer. 2. Apply power to the scanner. 3. In the Firmware Update dropdown menu, select App Code. This will open a dialog that allows the user to browse for the application code file. 4. Navigate to where the application code file (a *.mot file) is located on the host computer. 5. Allow approximately a minute for firmware to download. As the application code begins to download, the scanner will be silent, the LEDs will flash intermittently, and a progress indicator at the bottom of the ESP window will show when the download is complete. Caution: Do not interrupt power or disconnect the host cable while download is in progress.
QX-830 Compact Industrial Scanner User Manual
7-17
Page 276
Firmware
Firmware Verification Request Part Number Send a request to the scanner for application code, boot code, or FPGA code part numbers. 1. Click the Firmware tab. 2. Select App Code, Boot Code, or FPGA Code from the dropdown menu to the left of the Request Part No. button. 3. Click the Request Part No. button to see the part number displayed in the text field to the right.
Request Part Number by Serial Command • When <#> (a request for all product part numbers) is sent, the scanner returns: <#b/BOOT_P/N><#a/APP_P/N><#p/PROFILE_P/N>. • When <#a> (a request for the application code part number) is sent, the scanner returns: <#a/APP_P/N>. • When <#b> (a request for the boot code part number) is sent, the scanner returns: <#b/BOOT_P/N>. • When <#f> (a request for the FPGA code part number) is sent, the scanner returns: <#f/FPGA_P/N>.
7-18
QX-830 Compact Industrial Scanner User Manual
Page 277
Utilities
Request Checksum Send a request to the scanner for application code, boot code, or FPGA code checksums. 1. Click the Firmware tab. 2. Select App Code, Boot Code, or FPGA Code from the dropdown menu to the left of the Request Checksum button. 3. Click the Request Checksum button to see the part number displayed in the text field to the right.
Request Checksum by Serial Command • When <!> (a request for all available firmware checksums) is sent, the scanner returns: <!b/BOOT_CHECKSUM><!a/APP_CHECKSUM><!p/PROFILE_CHECKSUM> • When <!a> (a request for the application code checksum) is sent, the scanner returns: <!a/APP_CHECKSUM> • When <!b> (a request for the boot code checksum) is sent, the scanner returns: <!b/BOOT_CHECKSUM> • When <!f> (a request for the FPGA code checksum) is sent, the scanner returns: <!f/FPGA_CHECKSUM>
QX-830 Compact Industrial Scanner User Manual
7-19
Page 278
Default / Reset / Save
Default / Reset / Save
Saved for Power-on
Resets (not saved for power-on)
Understanding and controlling the scanner’s active, saved, and default settings is critical to its successful operation. Function
Serial Cmd
Reset (Will not save for power-on)
<A>
Reset and Recall Power-On Parameters Reset and Recall Customer Default Parameters Reset and Recall Microscan Default Parameters
ESPa
EZ Button
<Arp>
Save to Reader, Send No Save Send <Arp> from Terminal
No
<Arc>
Send <Arc> from Terminal
No
<Ard>
Send <Ard> from Terminal
No
Save to Reader, Send and Save Save to Reader, Send and Save Customer Defaults for Power-Onb
No
Save Current Settings for Power-On
<Z>
Save Current Settings as Customer Default Parameters for Power-On
<Zc>
Recall Customer Default Settings and Save for Power-On
<Zrc>
Send <Zrc> from Terminal
Press and hold while powering on scanner
<Zrd>
Send <Zrd> from Terminal
No
<Zrdall>
Send <Zrdall> from Terminal
No
Recall Microscan Default Settings and Save for Power-On (Will not default “sticky settings”) Recall Microscan Default Settings and Save for Power-On (Will also default “sticky settings”)
No No a. When right-clicking in a tree control to select Default Current Menu Settings or Default All ESP Settings, it is important to note that only ESP settings are defaulted. To save these defaults to the scanner itself, follow up with a Save to Reader, Send and Save command. b. Only available in ESP if enabled in Preferences (General tab), accessible from the Options dropdown menu.
Resets Resets (“A” commands) affect only the current settings (active memory) and are not saved for power-on.
Saved for Power-on Power-on parameters (“Z” commands) are saved to NOVRAM and recalled and loaded into current parameters when power is cycled to the scanner or the <Arp> command is issued.
Defaults Defaults are Microscan firmware settings or saved customer settings that can be recalled, either by software or hardware reset.
7-20
QX-830 Compact Industrial Scanner User Manual
Page 279
Utilities
Customer Default Parameters Customer default parameters (saved by <Zc>) are the same set of parameters as power-on parameters but are saved in a different, isolated section of NOVRAM. This allows a user essentially to create a back-up set of parameters that can be recalled in the event that the current parameters or power-on parameters have been accidentally changed or are no longer desired. It is important to note that a hardware default does not affect customer default parameters. For example, a user that has inadvertently changed communication settings and saved them with a <Z> command, may not know the correct settings or have the capability to communicate within those settings. By first doing an EZ Button default to restore the known Microscan defaults, the user can then recall the previous customer-saved settings with an <Arc> or <Zrc> command.
Restore Customer Defaults Use the EZ Button to default the scanner by holding it down while applying power to the scanner (if this feature is enabled).
Microscan Default Parameters Microscan default parameters are contained in the firmware and cannot be changed.
Software Defaults Microscan default parameters can be recalled (loaded into current settings) with the <Ard> command or recalled and saved for power-on with the <Zrd> command.
Restore Microscan Defaults If a software default and reset is not possible, it may be necessary to reset the scanner by shorting (connecting) specific pins. This procedure has the same effect as the <Zrd> software command. Important: For this reset to occur, this command must be executed within 60 seconds of a power-on or a reset. • Apply power to the scanner. • Locate default pin and ground. • Momentarily connect these wires (or pins) and listen for a series of short beeps. • Within 3 seconds, connect them again. A longer beep should be heard. If not, repeat the process.
Default on Power-On Use the EZ Button to default the scanner by holding it down while applying power to the scanner (if this feature is enabled).
QX-830 Compact Industrial Scanner User Manual
7-21
Page 280
Scanner Status Requests
Scanner Status Requests <K?> All Status Request This is the fastest way to learn the scanner’s current configuration. Sending this request will return the current settings of all commands, starting with the lowest K command value and ending with the highest K command value.
<K??> All Descriptor Status Request This request will return all current descriptors for every K command, starting with the lowest K command value and ending with the highest K command value.
<K?#> All Range Status Request This request will return the current settings of all commands within the user-defined range, starting with the lowest user-defined K command value and ending with the highest user-defined K command value.
<Knnn?> Single Status Request This request will return the value of the variables associated with the requested K command. The request of a single entry of a database command cannot exceed the number of database slots for the specific command.
<Knnn??> Single Descriptor Status Request This request returns the basic functional description of all fields in the requested K command.
<Knnn?#> Single Range Status Request This request will return the value range and storage type description of all fields in the requested K command.
<Knnnd> Default Customer Parameter This request will default a single K command if the command has customer-defined parameters rather than factory-defined parameters.
7-22