The text of a manual · part 25 of 43
QX-830 Compact Industrial Scanner User Manual, pages 241 to 250
Pages 241 to 250 of 422
The original document is the PDF (7.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan QX-830
Page 241
Scanner Parameters
Sequence Step When the master symbol is sequenced (incremented/decremented), Sequence Step defines the magnitude of change.
New Master Pin If Matchcode and New Master Pin are enabled and the new master pin is momentarily connected to ground (must be held low for a minimum of 10 ms), master symbol information will be loaded into the database based on the next read cycle that achieves a Good Read, starting with Index 1. The Master Database will be loaded with all symbols decoded in the read cycle as long as it does not exceed the Master Symbol Database Size parameter.
New Master Load Status The new master status responds with the number of the next master position to be loaded, where 0 represents “idle” or “no master to be loaded.” Example: If the user has the Master Symbol Database Size set to 1, and then either sends a <G> or toggles an active New Master Pin, the state will be 1, and prior to reading and effectively loading position 1, the response to <NEWM> would be <NEWM/1>. Once a symbol has been read and loaded, the status will be cleared: <NEWM/0>.
QX-830 Compact Industrial Scanner User Manual
5-175
Page 242
Matchcode
Match Replace Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol matches a master symbol. Outputs a user-defined data string whenever a match occurs and Matchcode is enabled.
Replacement String User-defined data string that, when enabled, replaces symbol data whenever a match occurs.
Mismatch Replace Provides a convenient shortcut for applications that need to output a predefined text string whenever a symbol does not match a master symbol. Outputs a user-defined data string whenever a mismatch occurs and Matchcode is enabled.
Replacement String User-defined data string that, when enabled, replaces symbol data whenever a mismatch occurs.
5-176
QX-830 Compact Industrial Scanner User Manual
Page 243
Scanner Parameters
Diagnostics Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Diagnostics tab to display the Diagnostics tree control.
The * indicates that the setting is the default.
To open nested options, single-click the +.
To change a setting, double-click the setting and use the cursor to scroll through the options.
Note: Matchcode settings can also be sent to the scanner from ESP’s Terminal using Microscan’s K command format. Refer to the Diagnostics section of Appendix E.
QX-830 Compact Industrial Scanner User Manual
5-177
Page 244
Diagnostics
Counts (Read-only)
Power-On 16-bit counter that increments on scanner power-on. Used for detecting unwanted resets caused by power supply problems or ESD transients. Returns the number of times the scanner has been re-powered or a watchdog reset occurs. 0 to 65,535 power-ons.
Resets 16-bit counter that increments every time the scanner is reset. Value is reset on power-on. Used for detecting unwanted resets caused by power supply problems or ESD transients. Resets include watchdog reset, <A>, <Z>, <Zd>, and hardware defaults. A watchdog reset is a reset that is forced whenever the software locks up. 0 to 65,535 resets.
Power-On Saves 16-bit counter that increments every time a scanner setting is saved for power-on.
Custom Default Saves 16-bit counter that increments every time a scanner setting is saved to the customer parameter section of flash memory.
5-178
QX-830 Compact Industrial Scanner User Manual
Page 245
Scanner Parameters
Hours Since Reset (Read-only) Used as a troubleshooting tool that can help pinpoint the cause of a reset. Records the number of hours and minutes of operation since the last system reset.
Hours 16-bit counter that increments every 60 minutes. Range: 0 to 23 hours.
Minutes 16-bit counter that increments every 60 seconds. Range: 0 to 59 minutes.
QX-830 Compact Industrial Scanner User Manual
5-179
Page 246
Diagnostics
Laser High When Enabled, a Laser High message is transmitted whenever the laser current exceeds a factory-calibrated reference value which cannot be altered. The message repeats once every 30 minutes until the condition is corrected. Alerts the user to impending laser failure. (Contact Microscan Service.)
Status Allows the user to Enable or Disable the Laser High message.
Message Defines the Laser High message.
5-180
QX-830 Compact Industrial Scanner User Manual
Page 247
Scanner Parameters
Laser Low When Enabled, a Laser Low message is transmitted whenever the laser current falls below a factory-calibrated reference value which cannot be altered. The message repeats once every 30 minutes until the condition is corrected. Alerts the user to impending laser failure. (Contact Microscan Service.)
Status Allows the user to Enable or Disable the Laser Low message.
Message Defines the Laser Low message.
QX-830 Compact Industrial Scanner User Manual
5-181
Page 248
Diagnostics
High Temperature Threshold A message can be defined that will display when a user-defined High Temperature Threshold has been reached. The message repeats once every 30 minutes until the condition is corrected. This value is a reference to the external ambient temperature in the environment around the scanner. Helps ensure that the scanner is being used within its temperature specification. Also, since hotter environments tend to shorten the life of electronics components, a user may want to set the temperature threshold closer to the nominal temperature of 25° F. A user can set a temperature value that when exceeded will cause a high temperature message to be displayed. If High Temperature Threshold is set to zero, the warning message is disabled.
Status Allows the user to Enable or Disable the High Temperature Threshold.
Message The user can enter a message of up to 10-characters that will be displayed whenever High Temperature Threshold is exceeded.
5-182
QX-830 Compact Industrial Scanner User Manual
Page 249
Scanner Parameters
Low Temperature Threshold A message can be defined that will display when a user-set Low Temperature Threshold has been reached. The message repeats once every 30 minutes until the condition is corrected. This value is a reference to the external ambient temperature in the environment around the scanner. Helps ensure that the scanner is being used within its temperature specification. The user can set a low temperature value that, whenever the ambient temperature falls below it, causes a low temperature message to be displayed. If Low Temperature Threshold is set to zero, the warning message will be disabled.
Status Allows the user to Enable or Disable the Low Temperature Threshold.
Message The user can enter a message of up to 10-characters that will be displayed whenever the ambient temperature falls below the Low Temperature Threshold.
QX-830 Compact Industrial Scanner User Manual
5-183
Page 250
Diagnostics
Service Message Status When Enabled, a Service Message of up to 128 characters is sent whenever the system detects that the service time has expired.
Service Message Allows the user to define a service message of up to 128 characters.
Threshold Allows the user to determine the length of time until the service message will be sent.
Resolution The service timer has a resolution field for setting up the timer increment. Options are increments of seconds or minutes.
5-184
QX-830 Compact Industrial Scanner User Manual