Page 231

Scanner Parameters

Low Temperature Activates output when the temperature drops below factory-defined lower limits.

QX-830 Compact Industrial Scanner User Manual

5-165

Page 232

I/O Parameters

Quality Output

Quality Output Separator The separator character separates quality output data from symbol data.

Decodes per Trigger Status When Enabled, the scanner enters a state where it processes frames as configured until the end of a read cycle, with or without a successful symbol decode. When the read cycle ends, the scanner outputs any decoded symbol data along with the decodes per trigger count.

Decode Direction Output When Enabled, compares the symbol decode direction to the direction specified in Output Filter Configuration.

5-166

QX-830 Compact Industrial Scanner User Manual

Page 233

Scanner Parameters

Symbol Position Output

Scan Status When Enabled, the location of the symbol within the scan line is appended to the symbol data output. The scan position is formatted with a leading identifier of “SP” plus two zero-padded three digit numbers (corresponding to the first and last bar of the symbol for most symbologies), separated by a colon. The scan position values correspond to the configurable Laser On/Off position values in the Laser Setup command. Example: Assume a symbol with the data “HELLO” is read when its first bar is at 20% of the scan width. The width of the symbol is 13% of the scan line. The data output would be “HELLO SP020:013”, assuming that no other outputs or formatting were enabled.

Separator This character separates all other symbol information from the Scan Status data field.

QX-830 Compact Industrial Scanner User Manual

5-167

Page 234

Matchcode

Matchcode Click the App Mode button and then the Parameters button to display the tree control tabs. Then click the Matchcode tab to display the Matchcode tree control.

The * indicates that the setting is the default.

To open nested options, single-click the +.

To change a setting, double-click the setting and use the cursor to scroll through the options.

Note: Matchcode settings can also be sent to the scanner from ESP’s Terminal using Microscan’s K command format. Refer to the Matchcode section of Appendix E.

5-168

QX-830 Compact Industrial Scanner User Manual

Page 235

Scanner Parameters

Overview of Matchcode Matchcode allows the user to store master symbol data in the scanner’s memory, compare that data against other symbol data, and define how symbol data and/or discrete signal output will be directed. A master symbol database can be set up for up to 10 master symbols. Note: Matchcode will function with multiple symbols; however, if Matchcode Type is set to Sequential or if Trigger Mode is set to Continuous Read 1 Output, the scanner will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration. Matchcode is used in applications to sort, route, or verify data based on matching the specific symbol in a variety of ways as defined in this section. For example, a manufacturer might sort a product based on dates that are embedded in the symbol.

Steps for Entering and Using Master Symbols 1. Set Trigger Mode to External Level, External Edge, or Serial Data. 2. Choose the method of symbol comparison that fits the application. 3. Define the type of output required with Matchcode setup: a. Symbol data output b. Discrete output 4. Select the number of master symbols required. 5. Decide how the master symbol(s) will be entered: a. Use ESP to type master symbol data directly. b. Send a serial command with symbol data in the form of <K231,master symbol#, data>. c. Send a <G> (Read Next Symbol as Master Symbol) command. d. Enable the New Master Pin command and activate the discrete input to store the next symbol read as the master symbol.

QX-830 Compact Industrial Scanner User Manual

5-169

Page 236

Matchcode

Matchcode Type Allows the user to choose the way that master symbols will be compared with subsequently read symbols. Note: First set Trigger Mode to External Level, External Edge, or Serial Data.

Sequential Instructs the scanner to compare symbols or portions of symbols with the master symbol. Instructs the scanner to sequence after each match (numeric only) and compare symbols or portions of symbols for sequential numbers.

Wild Card Allows the user to enter user-defined wild card characters in the master symbol. Note: If Matchcode Type is set to Sequential, the scanner will behave as if Number of Symbols were set to 1, regardless of the user-defined configuration.

Sequential Matching Useful in tracking product serial numbers that increment or decrement sequentially. With Sequential enabled, Sequential Matching determines if a count is in ascending (incremental) or descending (decremental) order.

5-170

QX-830 Compact Industrial Scanner User Manual

Page 237

Scanner Parameters

Match Start Position Match Start Position is useful in defining specific portions of a symbol for comparison. For example, if a symbol contains a part number, manufacturing date, and lot code info, but only the part number information is needed, set the scanner to sort only the part number and to ignore the other characters. Match Start Position determines the portions of symbols that will be matched by defining the first character in the symbol (from left to right) that will be compared with those of the master symbol, when Matchcode Type is set to Enabled or Sequential. For example, if Match Start Position is set to 3, the first 2 characters read in the symbol will be ignored and only the 3rd and subsequent characters to the right will be compared, up to the number of characters specified by Match Length. Note: Match Start Position must be set to 1 or greater to enable this feature. A 0 setting will disable this feature.

Match Length Example: If Match Length is set to 6 in a 10-character symbol, and Match Start Position is set to 2, only the 2nd through 7th characters (from left to right) will be compared. Defines the length of the character string that will be compared with that of the master symbol when Match Start Position is set to 1 or greater. When Match Start Position is set to 0, no comparison will occur.

QX-830 Compact Industrial Scanner User Manual

5-171

Page 238

Matchcode

Wild Card Example: With Wild Card Character defined as the default asterisk, defining CR*34 as the master symbol will result in matches for CR134 and CR234, but not CR2345. Entering the wild card at the end of the master symbol, as in CR*, will result in matches for variable symbol lengths such as CR1, CR23, CR358, etc. Wild Card Character allows a user to define a wild card character as part of the master symbol.

5-172

QX-830 Compact Industrial Scanner User Manual

Page 239

Scanner Parameters

Sequence on No Read Sequence on No Read is useful when the scanner needs to stay in sequence even if no decode occurs. When Sequence on No Read is Enabled and Matchcode Type is set to Sequential, the scanner sequences the master symbol on every match or No Read. When disabled, it does not sequence on a No Read.

Consider the following decodes as an example of Sequence on No Read Enabled: Master Symbol 001 002 003 004 005 006 007

Decoded Symbol 001 002 No Read 004 No Read No Read 007

Master Symbol after Decode 002 003 004 (sequence on No Read) 005 006 (sequence on No Read) 007 (sequence on No Read) 008

Consider the following decodes as an example of Sequence on No Read Disabled: Master Symbol 001 002 003 003 004 004 004

Decoded Symbol 001 002 No Read 003 No Read No Read 004

QX-830 Compact Industrial Scanner User Manual

Master Symbol after Decode 002 003 003 (not sequenced) 004 004 (not sequenced) 004 (not sequenced) 005

5-173

Page 240

Matchcode

Sequence on Mismatch Note: Matchcode Type must be set to Sequential for this command to function. Enable this parameter if every trigger event should have a decode and more than one consecutive mismatch may occur. When set to Enabled, the master symbol sequences on every decode, match, or mismatch. Disable this parameter if every trigger event should have a decode but no more than one consecutive mismatch may occur. When set to Disabled, the master symbol will not sequence whenever consecutive mismatches occur. The scanner will sequence the master to one more or one less than the decoded symbol.

Consider the following decodes as an example of Sequence on Mismatch Enabled: Master Symbol 001 002 003 004 005 006 007

Decoded Symbol 001 002 abc 004 def ghi 007

Master Symbol after Decode 002 003 004 (sequence on mismatch) 005 006 (sequence on mismatch) 007 (sequence on mismatch) 008

Consider the following decodes as an example of Sequence on Mismatch Disabled: Master Symbol 001 002 003 004 005 006 006

5-174

Decoded Symbol 001 002 abc 004 def ghi 006

Master Symbol after Decode 002 003 004 (sequenced because of previous match) 005 006 (sequenced because of previous match) 006 (not sequenced) 007

QX-830 Compact Industrial Scanner User Manual