The two-page Microscan quick start guide (P/N 83-210041 Rev P) for the MS-Q Imager. It shows how to set the imager up by USB, PS/2, RS-232, Bluetooth or battery with batch storage, then install the ESP software and connect the imager to it.
- Imager part numbers
- FIS-6100-XXXXG or FIS-6150-XXXXG p. 1
- Connections
- USB, PS/2, RS-232, Bluetooth, or battery with batch storage p. 1, 2
- USB and PS/2 power
- Drawn from the host p. 1
- Keyboard wedge cable
- 60-000018-03 for PS/2 p. 1
- RS-232 hookup
- RS-232 kit with cable and power supply; 8-pin mini-DIN to the MS-Q, 9-pin D-sub to the host serial port p. 1
- RS-232 terminal settings
- 57.6K baud, 8 data bits, none parity, 2 stop bits p. 1
- Bluetooth modem
- USB Bluetooth Modem 98-000076-10 (default option); RS-232 options 98-000076-07, -08, -09 p. 1
- Bluetooth terminal settings
- 9600 baud, 8 data bits, none parity, 1 stop bit p. 1
- Handles
- H2 Cabled Handle plugs into the MS-Q's 8-pin DIN connector; BH1 or BH2 Handle holds the battery p. 1, 2
- Batch modes
- Send and Log keeps buffered data in memory after download; Send and Buffer erases it p. 2
- Setup software
- ESP, on the Microscan Tools CD packaged with the MS-Q p. 2
- ESP requirements
- Windows Vista, XP or 2000; Internet Explorer 5.0 or higher; 64 MB RAM; 40 MB disk; 166 MHz Pentium recommended p. 2
What this manual walks you through
- Assembling the MS-Q on the H2 Cabled Handle p. 1
- Setting up the imager on USB as a keyboard p. 1
- Setting up the imager on a PS/2 keyboard port p. 1
- Setting up the imager on RS-232 p. 1
- Setting up the imager with a Bluetooth modem p. 1
- Fitting the battery handle and using batch mode p. 2
- Installing ESP and connecting the imager to it p. 2
Good to know
- Battery-powered MS-Q imagers should be charged for 4 hours before first use. p. 1
- In Send and Buffer mode the buffered data is erased from the imager once downloaded. p. 2
- The imager must be in USB or RS-232 mode to connect to ESP. p. 2
Questions this manual answers
What serial settings does the MS-Q use on RS-232?
The guide has you set the terminal program to 57.6K baud, 8 data bits, none parity and 2 stop bits. p. 1
How do I set up the MS-Q on USB?
Connect the USB cable to the MS-Q and the host, open a program that takes keyboard text, then read the USB Keyboard and Save Settings symbols. p. 1
How long should I charge a battery MS-Q before first use?
4 hours. p. 1
What is the difference between Send and Log and Send and Buffer?
Both download buffered data when you connect. Send and Log keeps it in the imager's memory; Send and Buffer erases it. p. 2
What computer do I need to run ESP for the MS-Q?
Windows Vista, XP or 2000, Internet Explorer 5.0 or higher, 64 MB RAM and 40 MB disk space, with a 166 MHz Pentium recommended. p. 2
The file
Size and text
Every page · 2
Read it here
Each page as it is printed, and its words beside it, so a phone can search and copy them.
Page1of 2
Open in the PDF
The text of page 1, from the PDF itself
Quick Start Guide
MS-Q Imager
Step 1, Check Required Hardware Important: It is recommended that battery-powered MS-Q imagers be charged for 4 hours before first use.
Step 2, Set Up Hardware (USB) Note: The USB interface draws its power from the host. Hardware for USB
To assemble the MS-Q Imager with Cabled Handle (H2): 1. Insert the flexible connector at the back of the H2 Handle into the MS-Q’s 8-pin DIN connector. 2. Snap the imager onto the H2 Handle over the battery blank. Be sure that the underside of the imager is latched at the front of the handle. 3. Secure the flexible connector at the back of the H2 Handle with the two screws provided. 4. Secure the underside of the imager to the H2 Handle with the two screws provided. 5. Attach the cable to the bottom of the handle. Secure the cable and cable clamp with the two screws provided. 3
1
MS-Q Imager
FIS-6100-XXXXG FIS-6150-XXXXG
2USB CableIncluded
Installation Steps for USB 1. Connect the USB cable (2) to the MS-Q (1). 2. Connect the USB cable (2) to the host. You do not need to power off your host computer. 3. Open any program in your host computer that can receive keyboard text. 4. Read the USB Keyboard symbol below. 5. Read the Save Settings symbol below.
5
4
Note: Detailed instructions for the MS-Q Imager’s handle options are available in the MS-Q Imager User’s Manual.
USB Keyboard Mode
P/N 83-210041 Rev P
Step 2, Set Up Hardware (PS/2) Note: The PS/2 interface draws its power from the host. Hardware for PS/2 1
MS-Q Imager
FIS-6100-XXXXG FIS-6150-XXXXG
2Keyboard Wedge Cable60-000018-03
Installation Steps for PS/2 1. Power-off the host and disconnect the keyboard. 2. Connect the PS/2 cable (2) to the MS-Q (1). 3. Attach the remaining connectors to the keyboard cable and host computer, as shown at right. 4. Power-on the host computer. 5. Read the PS/2 Mode and Save Settings symbols.
PS/2 ModeSave SettingsPS/2 Hardware
Test Symbol (ABCDEFGHIJKLMNOP)
Step 2, Set Up Hardware (RS-232) Hardware for RS-232 1
RS-232 Kit includes: RS-232 Cable
3
Power Supply
Test Symbol (ABCDEFGHIJKLMNOP)
Step 2, Set Up Hardware (Bluetooth)
FIS-6100-XXXXG FIS-6150-XXXXG
198-000074-XX2
USB Bluetooth Modem (Default option) 98-000076-10
3USB CableIncluded with kit
Note: RS-232 options also available
98-000076-07, -08, -09
Installation Steps for RS-232 1. Power-off the host. 2. Connect the 8-pin mini-DIN on the RS-232 cable (2) to the MS-Q (1). 3. Connect the 9-pin D-sub connector to your host computer’s serial port. 4. Connect the RS-232 cable to the power supply cable. 5. Plug in the power supply (3) and power-on RS-232 Hardware the host. 6. Open a terminal program (HyperTerminal, for example) and set 57.6K baud rate, 8 data bits, none parity, 2 stop bits, none hardware. 7. Read the RS-232 Default Settings Mode symbol below. 8. Read the Save Settings symbol below.
RS-232 Default Settings Mode
Save SettingsHardware for BluetoothMS-Q Imager2USB HardwareSave Settings
Test Symbol (ABCDEFGHIJKLMNOP)
FIS-6100-XXXXG FIS-6150-XXXXG
MS-Q Imager
Installation Steps for Bluetooth 1. Power-off the host. 2. Connect the 8-pin mini-DIN on the Bluetooth modem (2). 3. Connect the 9-pin D-sub connector (3) to your host computer’s serial port. 4. Connect the RS-232 cable to the power supply cable (4). Bluetooth Hardware 5. Plug in the power supply (4) and power-on the host. 6. Open a terminal program (HyperTerminal, for example) and set to 9600 baud rate, 8 data bits, none parity, 1 stop bit, none hardware. 7. Read the RF Two-Way Mode symbol below. 8. Read the symbol on the Bluetooth modem’s top label (2). 9. Read the Save Settings symbol below.
RF Two-Way Mode
Save Settings
Test Symbol (ABCDEFGHIJKLMNOP)
Page2of 2
Open in the PDF
The text of page 2, from the PDF itself
Step 2, Set Up Hardware (Batch/Battery) Hardware for Batch/Battery 1
MS-Q Imager
FIS-6100-XXXXG FIS-6150-XXXXG
2BatteryIncluded
Installation Steps for Batch/Battery 1. Insert the tab on the back of the BH1 or BH2 Handle into the Tab imager’s recessed slot at the base of the battery bay. 2. Snap the imager onto the BH1 or BH2 Handle over the battery. Be sure that the underside of the imager is latched at the front of the handle. 3. Secure the underside of the imager to the BH1 or BH2 Handle with the two screws provided. 4. Select one of the Batch Setup modes - Send and Log, or Send and Buffer. 5. Read symbols as required. 6. Save settings. 7. When convenient, or when the buffer is full, open any Windows-compatible program that can accept keyboard text (for USB and PS/2) or serial data (for RS-232 and Bluetooth). 8. Attach a cable or connect to Bluetooth to download buffered data.
Step 4, Select Model When you start ESP, the following menu will appear:
Step 2, Set Up Hardware (Batch/Battery, cont.) Batch Setup - Send and Log Mode In Send and Log Mode, whenever you connect, all buffered data will be downloaded to the host but retained in the imager’s memory.
ESP Software can be found on the Microscan Tools CD that is packaged with the MS-Q. 1. Follow the prompts to install ESP from the CD. 2. Click on the ESP icon to run the program.
Send and Log Mode
Note: ESP can also be installed from the Download Center at www.microscan.com. Batch Setup - Send and Buffer Mode In Send and Buffer Mode, whenever you connect, all buffered data will be downloaded to the host and ERASED in the imager’s memory.
Send and Buffer Mode
ESP System Requirements
- 166 MHz Pentium processor (recommended)
- Windows Vista, XP, or 2000 operating system
- Internet Explorer 5.0 or higher
- 64 MB minimum RAM
- 40 MB minimum disk space Important: The imager must be in USB or RS-232 Mode to connect to ESP. Read the symbol below that corresponds with your communication interface.
Save SettingsUSB ModeTest SymbolRS-232 Mode(ABCDEFGHIJKLMNOP)
Step 5, Select Protocol In the Select Protocol dialog box, select the communications protocol you are using and click Next.
RS-232
Print the RS-232 Mode symbol and read it with the imager to ensure that you are in the correct communications mode. Keep the printed symbol in a convenient place for future use. Click Next when you are finished.
USB
1. Click the MS-Q button and then click OK. If you do not want to make this selection every time you start ESP, uncheck “Show this dialog at startup”. 2. Select the default reader name (MS-Q-1), or type a name of your choice in the Description text field and click OK. 3. Click Yes when this dialog appears:
Step 3, Install ESP
1. Print the USB Mode symbol and read it with the imager to ensure that you are in the correct communications mode. Keep the printed symbol in a convenient place for future use. Click Next when you are finished. 2. This will bring up the USB Reader ID dialog. You will see a reader ID in the Select Device field. Click Next. Note: If the imager is in the default USB Keyboard Mode when you attempt to connect, the USB Reader ID dialog will tell you to click the Switch Mode button. ESP will attempt to switch the imager to USB HID Mode. Once the imager has switched modes, click Next.
Step 6, Connect and Configure the Imager RS-232 Click Next in the Connect Mode dialog (Step 5) to bring up the Com Port dialog, shown below.
1. Select the communications port you are using. If you don’t see your com port listed on the dropdown menu, select Other. 2. Click Connect. When you are connected successfully, the CONNECTED message will appear in a green box in the status bar at the bottom right of the screen.
USB Click Next in the USB Reader ID dialog (Step 5) to connect the imager to ESP. When you are connected successfully, the CONNECTED message will appear in a green box in the status bar at the bottom right of the screen.
You are now ready to configure the imager using ESP.