Page 261

Wiring Box

New Master Pin Allows you to wire in a switch for New Master Pin. (See Optoisolator Inputs on page A-7.)

Trigger Port (NPN) To initiate the read cycle. (See Optoisolator Inputs on page A-7.)

Power LED GREEN means the polarity of the input connections is correct; RED means it is reversed. Caution: While the MS-890 scanner has reverse polarity protection built in to its circuitry, the wiring box does not protect external circuits that may already be wired in when power is applied.

MS-890 Industrial Automation Scanner User’s Manual

14-7

Page 262

Wiring Box PCB with Connectors

Wiring Box PCB with Connectors

14-8

MS-890 Industrial Automation Scanner User’s Manual

Page 263

Wiring Box

Mounting Plate

IB-890 Wiring Box Mounting Plate

MS-890 Industrial Automation Scanner User’s Manual

14-9

Page 264

Mounting Plate

14-10

MS-890 Industrial Automation Scanner User’s Manual

Page 265

Appendices Appendix A General Specifications.............................................................................................. A-2 Appendix B Electrical Specifications............................................................................................ A-4 Appendix C Serial Configuration Commands .............................................................................. A-9 Appendix D ASCII Table ............................................................................................................ A-15 Appendix E Embedded Menus .................................................................................................. A-17 Appendix F Defaulting / Saving / Initializing............................................................................... A-18 Appendix G Position Scanner and Symbol ................................................................................ A-21 Appendix H Object Detector ...................................................................................................... A-22 Appendix I Bar Code Configuration ........................................................................................... A-23 Appendix J Test Read Rate ....................................................................................................... A-25 Appendix K Formulas for Number of Decodes .......................................................................... A-27 Appendix L Operational Tips...................................................................................................... A-32 Appendix M Interface Standards................................................................................................ A-33 Appendix N Multidrop Communications..................................................................................... A-34 Appendix O Glossary of Terms.................................................................................................. A-39

MS-890 Industrial Automation Scanner User’s Manual

A-1

Page 266

General Specifications

Appendix A, General Specifications Mechanical Height: 3.5" (88 mm) Width: 5" (127 mm) Depth: 6" (152 mm) Weight: 5 lbs. (2268 g)

Environmental Enclosure: IP65 Operating Tempurature: 0° to 50°C (32° to 122°F) Storage Tempurature: -50° to 75° C (-58 to 167°F) Humidity: up to 90% (non-condensing)

Emissions and Immunity EN61000-6-3:2001: for Class A products EN61000-3-2:2000+A2:2005 EN61000-3-3:1995+A1:2001 EN61000-6-2: Immunity

Laser Light Type: Semiconductor visible laser diode (650 nm nominal) Operating Life: 50,000 hours @ 25°C (77°F) Safety Class: CDRH Class II

Indicators Beeper: Good Read, Match/Mismatch, No Read, serial command confirmation LEDS: 1 status, 1 power, 1 Good Read, 5 read performance (representing percentage of good decodes), network/include status, green flash

Discrete I/O Trigger, New Master, Input 1: Optoisolated, 5-28V rated (12mA at 24VDC) Outputs (1, 2, 3): Optoisolated, 1-28VDC rated, (ICE<100mA @ 24VDC, current limited by user)

Communications Interface: RS-232, RS-422485, Daisy Chain/Aux Port-capable, dedicated configuration port

MS-890 Dimensions

Symbologies Standard symbologies: Code 39, Code 128, UPC/EAN, Interleaved 2 of 5, Codabar, Code 93, PDF417 Applications Standards: AIAG, GS1-128

Scanning Parameters Scanner Mirror Type: Rotating, single line, 14-faceted Scan Rate: Adjustable from 400 to 1000 scans/second (default = 500 scans/second) Raster Sweep Speed: 1 to 30 sweeps/second Raster Sweep Angle: 30° maximum Scan Width Angle: Typically 60° Pitch Angle: ±50° maximum Skew Angle: ±40° maximum Contrast: 25% min. absolute dark-to-light differential at 650 nm wavelength

A-2

MS-890 Industrial Automation Scanner User’s Manual

Page 267

Appendices Read Ranges Symbol/Narrow Bar Width 7.5 mil (.190 mm) 10 mil (.254 mm) 15 mil (.381 mm) 20 mil (.508 mm) 30 mil (.762 mm) 40 mil (1.020 mm) 50 mil (1.27 mm)

Read Range 10” to 35” (254 to 889 mm) 10” to 44” (254 to 1118 mm) 10” to 74” (254 to 1880 mm) 10” to 90” (254 to 2286 mm) 10” to 100” (254 to 2540 mm) 10” to 110” (254 to 2794 mm) 10” to 120” (254 to 3048 mm)

FIS Options MS-890 Industrial Automation Scanner Long Range, Stand Alone Version, RS-232/485, 10-28VDC Long Range, Wiring Box-Ready, RS-232/485, 10-28VDC

FIS-0890-0001G FIS-0890-0002G

Safety Certifications FCC, CDRH, CE, UL/cUL, BSMI, RoHS/WEEE Compliance

ISO Certification ISO 9001 Certified Issued by TüV USA ©2010 Microscan Systems, Inc. All rights reserved. Specifications subject to change. Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Performance characteristics may vary at high temperatures or other environmental extremes. Warranty–One year limited warranty on parts and labor. Extended warranty available.

MS-890 Industrial Automation Scanner User’s Manual

A-3

Page 268

Electrical Specifications

Appendix B, Electrical Specifications Maximum Operating Power: 24 Watts Power Requirement: 10 to 28VDC, 200mV p-p max. ripple, 230mA @ 24VDC (typ.) Trigger, New Master, Input 1: 4.5 to 28 VDC (optoisolated)

Pin 1

Connectors at the base of the MS-890 unit:: • Power Connector • Host 25-Pin Connector • Trigger Connector

Pin 25 2

1

3

1

2

3

4

2

1

3

Caution: Be sure that all cables are connected BEFORE applying power to the system. Always power down BEFORE disconnecting any cables.

Power Connector: 3-pin microchange plug 1 2 3

Power Ground N/C Power 10 to 28 VDC (in)

Caution: If using your own power supply, verify correct connection of power and ground lines. Incorrect connections or use of “Chassis ground,” “Power ground,” and “Signal ground” lines could cause equipment and/or software failure. Trigger Connector: 4-pin microchange socket 1 2 3 4

Power 10 to 28 VDC (out) NPN Ground N/C

Programming Connector: 9-pin D-sub plug 2 3 5 9

RX232 TX232 Signal Ground Boot Mode

Note: RS-422 and RS-232 are both enabled by default in the MS-890.

A-4

MS-890 Industrial Automation Scanner User’s Manual

Page 269

Appendices

Host 25-Pin Connector 25-pin D-sub plug Pin

Host RS-232

Host and Aux RS-232

Host RS-422/485

I/O a

1 Chassis Ground 2 Host TxD Out 3 Host RxD In 4 RTS Aux TxD Out 5 CTS Aux RxD In 6 Output 1 (+) Out 7 Signal Groundb 8 Output 2 (+) Out 9 Trigger (–) In 10 Trigger (+) In 11 N/C 12 Input 1 (+) In 13 RxD (+) In 14 TxD (–) Out 15 No Read/Output 3 (+) Out 16 RxD (–) In 17 Power Groundc 18 Power + 10 to 28 VDC In 19 TxD (+) Out 20 Output 1 (–) Out 21 Output 2 (–) Out 22 No Read/Output 3 (–) Out 23 Input 1 (–) In 24 New Master (–) In 25 New Master (+) In a. Chassis Ground: Used to connect chassis body to earth ground only. Not to be used as power or signal return. b. Signal Ground: Used for communication and signal line grounds only. Not to be used as power or chassis return. c. Power Ground: Used for power return only. CAUTION: If using your own power supply, verify correct connection of power and ground lines. Incorrect connections or use of Chassis Ground, Power Ground, and Signal Ground lines could cause equipment failure or software failure.

MS-890 Industrial Automation Scanner User’s Manual

A-5

Page 270

Electrical Specifications

Optoisolator Outputs Optoisolator circuits can transfer pulses between the scanner and peripherals with no direct connection with the scanner’s internal circuitry. However, not every optoisolator configuration provides complete isolation. The following diagrams show both fully optoisolated and non-optoisolated circuits. They are only examples and do not represent all possible wiring configurations. Iload=5mA

Iload=50mA

VOut-On

0.7V

0.9V

Iload=100mA 1.0V tOn-Typ

30 µS

20 µS

30 µS tOff-Typ

1000 µS

150 µS

75 µS

Output Circuit Examples Fully Optoisolated

Host

Isolated MS-880

This circuit is fully optoisolated and is the recommended configuration. It allows the user to apply 1 to 28VDC to the circuit. Caution: The maximum current that can pass through the optoisolator is 100mA.

Pwr +

Pin 18

Scanner Output

Pins 6,8,15 respectively paired with:

1 to 28 V

INPUT

Pins 20,21,22 Pwr –

Pin 17

Not Optoisolated, Scanner Grounded Host

Non-isolated MS-880 Pwr +

Pin 18

Scanner Output

Pins 6,8,15 respectively paired with:

INPUT

Pins 20,21,22 Pwr –

Pin 17

Host

Non-isolated MS-880 Pwr +

Pin 18

Scanner Output

Pins 6,8,15 respectively paired with:

1 to 28 V

INPUT

Pins 20,21,22 Pwr –

A-6

Pin 17

MS-890 Industrial Automation Scanner User’s Manual