Page 251

Output Format

Length Definition:

Specifies the length of the decoded symbol allowed to occupy this location in multisymbol output. Note: To filter or order a symbol, the symbol must meet all requirements of the selected filter index.

Serial Cmd:

<K744,filter number,symbology,length,wildcard,placeholder,data,decode direction,database index>

Default:

0

Options:

0 to 128

Wildcard Definition:

This is the character to be used in the data output field when performing a data filter comparison. The wildcard character represents the end of matching, and allows for variable lengths of symbol output.

Serial Cmd:

<K744,filter number,symbology,length,wildcard,placeholder,data,decode direction,database index>

Default:

“ * “ = (2A in hex)

Options:

Any ASCII input in the form of a pair of hex characters. Example: 2A = * 00 = disabled

Placeholder Definition:

The placeholder character requires a character to be present, but does not compare the data value.

Serial Cmd:

<K744,filter number,symbology,length,wildcard,placeholder,data,decode direction,database index>

Default:

“ ? ” = (3F in hex)

Options:

Any ASCII input in the form of a pair of hex characters. Example: 3F = ? 00 = disabled

MS-890 Industrial Automation Scanner User’s Manual

13-11

Page 252

Output Filter Configuration

Data Definition:

This is the data string to be used when comparing symbol data for output filtering and ordering. This data string may also contain wildcard and placeholder characters to facilitate matching. Remember that in order to filter or order symbol data, it must meet all the requirements of the selected filter index. Examples: • Filter data = “123*”. This will match data strings of “123”, “123456”, and “123ABC”, but not “12”. • Filter data = “123*AB?C”. This will be interpreted as “123*”. • Filter data = “123?”. This will match “1234” and “123A”, but not “123”, “12345”, or “1234C”. • Filter data = “123?A”. This will match “1234A” and “123BA”, but not “123”, “1234C”, or “1234ABCD”. • Filter data = “123?A?”. This will match “1234AB” and “123BAT”, but not “1234A” or “123BATS”. • Filter data = “12??*”. This will match “1234”, “123456”, and “123ABC”, but not “12” or “123”. • Filter data = “123?A*”. This will match “1234A”, “123BA”, and “123BATS”, but not “1234” or “1234C”.

Serial Cmd:

<K744,filter number,symbology,length,wildcard,placeholder,data,decode direction,database index>

Default:

NUL (00 in hex)

Options:

Any ASCII input in the form of a pair of hex characters. Maximum length: 63 bytes defined. Examples: 41422A = AB* Data [0] = NUL represents string matching disabled.

Decode Direction Definition:

Decode direction is determined by the direction of the output filter.

Serial Cmd:

<K744,filter number,symbology,length,wildcard,placeholder,data,decode direction,database index>

Default:

0 (any direction)

Options:

0 = Any Direction 1 = Forward 2 = Reverse

13-12

MS-890 Industrial Automation Scanner User’s Manual

Page 253

Output Format

Database Index Definition:

The index of the database entry that decodes a given symbol must equal this setting for filtering to occur. A setting of 0 allows any database index for this filter entry.

Serial Cmd:

<K744,filter number,symbology,length,wildcard,placeholder,data,decode direction,database index>

Default:

0

Options:

0 = Any Database Index 1 = Database # 1 to n (maximum number of characters in the symbol data)

MS-890 Industrial Automation Scanner User’s Manual

13-13

Page 254

Number of Filters

Number of Filters Definition:

Number of Filters refers to the number of active output filters. 0 disables all output filters. Any non-zero numeral will enable filtering to be performed using the filter indexes covered by this value. For example, if the number of filters is 1, then only filter index # 1 will be applied. If the number of filters is 2, then only filter index # 1 and filter index # 2 will be applied, etc.

Serial Cmd:

<K745,number of filters>

Default:

0

Options:

0 to 12

13-14

MS-890 Industrial Automation Scanner User’s Manual

Page 255

14 Wiring Box Contents Wiring Box Description ............................................................................................................... 14-2 Installation Steps ........................................................................................................................ 14-3 Wiring Box Ports......................................................................................................................... 14-5 Wiring Box PCB with Connectors ............................................................................................... 14-8 Mounting Plate............................................................................................................................ 14-9

This section has instructions for assembling, wiring and using the MS-890’s optional Wiring Box. When this option is selected, the MS-890 and wiring box option are shipped as an assembly.

MS-890 Industrial Automation Scanner User’s Manual

14-1

Page 256

Wiring Box Description

Wiring Box Description Note: The wiring box PCB resides inside the wiring box. Ribbon Cable to MS-890 Scanner

Portal hole, 3/4” pipe thread (4 places) Bottom mounting plate of wiring box

Portal Holes The wiring box has four external portal holes which are standard 3/4” pipe thread. Mounting of the box is with four through holes in flanges that extend out over the ends.

Terminal Strip Specifications Wire strip length: .24” (6 mm) Wiring range: 14 - 28 AWG Current: 13A maximum

14-2

MS-890 Industrial Automation Scanner User’s Manual

Page 257

Wiring Box

Installation Steps 1. Connect power through the portal holes (see Check Required Hardware on page 1-2). 2. Temporarily apply power to the scanner and confirm that the light next to the input terminal is green and not red. 3. Disconnect power before making the remaining connections. 4. Connect the host and trigger port wires through the portal holes to the appropriate connections. 5. Plug the ribbon cable into the scanner as shown below (apply pressure back and forth on the connector to ensure that it fits inside the receptacle).

Ribbon Cable

Bottom plate of scanner attaches to top of wiring box Portal holes 3/4” pipe thread (4 places)

Wiring box

Base mounting plate of wiring box

MS-890 Industrial Automation Scanner User’s Manual

14-3

Page 258

Installation Steps (cont.)

Installation Steps (cont.) 6. Attach the scanner to the wiring box with four attached mounting screws in the bottom plate of the scanner, making sure that the gasket is evenly seated.

Mounting screws (4 corners of base plate)

7. Mount the wiring box (see Wiring Box Ports on page 14-5).

14-4

MS-890 Industrial Automation Scanner User’s Manual

Page 259

Wiring Box

Wiring Box Ports Relay Modules These can be used as an alternative to the 3 optoisolated outputs from the scanner itself. K1, K2, and K3 are module sockets for SM off-the-shelf AC/DC output/relay modules. Note: For relay module kits, use a slim module that does not exceed 0.43” (11 mm) in width.

1.7" (1.1 cm)

Locking screw

0.43" (1.1 cm)

3 relay module sockets

40-3100 08-01 REV. 2

K2 P ASS

1 3 5

J10

33

2 4 6

JP1

J13

34

1

J9

J7

J8

JP3

JP2

1

2

3

4

5

6

2

1 3

4

J15 5

6

R E LA Y PA S S

J17

2

MADE IN U.S.A.

J12

MICROSCAN

R E LA Y

K3

43-310008REVS/N:

K1

1

2

3

5

6

+5

GND

+

–

TX+ TX–

RX+ RX–

GND C HS

R EL A Y 2 O U T RE LA Y 3 O U T

Jumpers When installing relay modules in K1, K2, and K3, corresponding jumpers (J1, J2, J3) need to be moved. Move jumpers from 3-5 to 1-3 and 4-6 to 2-4 for each relay to be installed (K1, K2, K3). Default jumper positions (using scanner’s built-in relay)

New jumper position (using pluggable relay) 1 3 5

2 4 6

2 4 6

JP1

JP1

JP2 JP3 40-31000 8-01 REV. 2

K1 K2 1

PASS

3 5

J10

33

JP 1

J13

1 1 3 5

34

J8

J9

J7

K3

JP3

JP2 2 4 6

1

2

3

4

J15 5

6

2

R EL A Y P A SS

J17 MA DE IN U.S.A.

J12

2 4 6

M ICROSCAN

RE L A Y

43-310008REVS/N:

1 3 5

1

MS-890 Industrial Automation Scanner User’s Manual

2

3

5

6

+5

GND

+

–

TX+ TX–

RX+

RX–

GND CHS

R ELA Y 2 O U T

R EL AY 3 O U T

14-5

Page 260

Wiring Box Ports

Relay Terminals Relay terminals 1, 2, and 3 provide output for both internal optoisolated outputs and alternative relay modules that can be installed in modules K1, K2, and K3.

Relay1 Output handles discrete outputs from the scanner that will switch up to 100 mA of optoisolated current.

+5 VDC Voltage out that can drive a hand held scanner. Maximum current is 5 watts.

Input 1 Used to wire a switch to reset latch mode or counters.

RS-422/485 Used for multidrop or 422 port.

Power 10-28 VDC Power input port (left side and right side for connectivity convenience).

RS-232 Main serial communication port.

Aux RS-232 Daisy chain and Auxiliary connections.