The text of a manual · part 18 of 31
MS-890 Industrial Automation Scanner User's Manual, pages 171 to 180
Pages 171 to 180 of 308
The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-890
Page 171
Diagnostics
Counts (This command is Read-Only.)
Power-Ons Definition
Returns the number of times the scanner has been re-powered or a watchdog reset occurs.
Serial Cmd:
Send: <K406?> Returns: <K406,power-ons,resets,parameter saves>
Read-Only Range:
0 to 65535 power-ons.
Resets Usage:
Used for detecting unwanted resets caused by power supply problems or ESD transients.
Definition
Resets include watchdog reset, <A> and <Z> commands, and hardware defaults. A watchdog reset is a reset that is forced whenever the software locks up.
Serial Cmd:
Send: <K406?> Returns: <K406,power-ons,resets,parameter saves>
Read-Only Range:
0 to 65535 resets.
Parameter Saves Definition
Returns the number of times parameters are written to memory, including <Z> commands and hardware defaults.
Serial Cmd:
Send: <K406?> Returns: <K406,power-ons,resets,parameter saves>
Read-Only Range:
0 to 65535 saves.
MS-890 Industrial Automation Scanner User’s Manual
8-3
Page 172
Hours Since Last Reset
Hours Since Last Reset (This command is Read-Only.) Usage:
Used as a troubleshooting tool that can help pinpoint the cause of a reset.
Definition:
Records the number of hours and minutes of operation since the last system reset.
Serial Cmd:
Send: <K407?> Returns: <K407,hours,minutes>
Read-Only Ranges:
8-4
0 to 255 hours, 0 to 59 minutes.
MS-890 Industrial Automation Scanner User’s Manual
Page 173
Diagnostics
Warning Messages Important Note: Warning Message Status must be enabled before any warnings in this menu can be displayed. Usage:
These messages serve as a flag to service a scanner or as an early warning that potential problems could arise. They are particularly useful in factories that run constantly and can’t afford down time.
Definition:
Warning messages that relate to the environment and condition of the scanner can be defined and set to activate specific outputs. Note: When enabled, the error condition will override all other operational modes configured for the output.When enabled, laser current and NOVRAM warning messages will be transmitted to the host or any active port whenever the pre-defined conditions are met.
Function:
When enabled, warning messages will be transmitted to the host or any active port. Note: This option must be enabled before any other warning messages can be transmitted.
Warning Message Status Serial Cmd:
<K400,warning message status,laser high status,laser low status, NOVRAM/reset warning status>
Default:
Disabled
Options:
0 = Disabled 1 = Enabled
Laser High Status When enabled, a message is transmitted whenever the laser current exceeds a factory-calibrated reference value which cannot be altered. The message repeats once every 30 minutes until the condition is corrected. Usage:
Alerts the user to impending laser failure.
Definition:
Enables the Laser High message.
Serial Cmd:
<K400,warning message status,laser high status,laser low status, NOVRAM/reset warning status>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
MS-890 Industrial Automation Scanner User’s Manual
8-5
Page 174
Warning Messages
Laser Low Status When enabled, a message is transmitted whenever the laser current falls below a factory-calibrated reference value which cannot be altered. The message repeats once every 30 minutes until the condition is corrected. Usage:
Alerts the user to impending laser failure.
Definition:
Enables the Laser Low message.
Serial Cmd:
<K400,warning message status,laser high status,laser low status, NOVRAM/reset warning status>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled
NOVRAM/Reset Warning Status When enabled, a 7-character message is sent whenever the system detects a warning condition. Important: Warning Message Status must be enabled before the NOVRAM message in this menu can be transmitted. Usage:
Alerts the user to NOVRAM failure.
Serial Cmd:
<K400,warning message status,laser high status,laser low status, NOVRAM/reset warning status>
Default:
Enabled
Options:
0 = Disabled 1 = Enabled Note: If you suspect that erroneous defaults are occurring, enable NOVRAM Messages by sending <K400,1,,,1>. This will allow the NOVRAM messages, if present, to be viewed.
Warning messages for NOVRAM can appear in one of five formats: <NVRAM-C> This message indicates an error in user settings. The message repeats once every 30 minutes. If this message is received, restore customer settings and send a <Z> command. <NVBAD-D> Indicates that diagnostic lifetime hours, power-on counts, and reset counts have been lost. The message repeats once every 30 minutes. <NVBAD-L> Indicates a problem with laser current factory reference. The message repeats once every 30 minutes. <DFALT-C> Indicates that the customer NOVRAM settings have been defaulted either by a customer initiated default or by a problem with the scanner. This message is sent ONLY ONCE. <DFALT-F> Indicates that the factory NOVRAM settings have been defaulted. This message is sent ONLY ONCE upon reset. 8-6
MS-890 Industrial Automation Scanner User’s Manual
Page 175
Diagnostics
Laser Current Warning Alerts the user to impending laser failure.
High Current Status Definition:
The High Current message is output whenever the laser current exceeds the factory-defined maximum. The message repeats once every 30 mimutes until the condition is eliminated.
Serial Cmd:
<K411,high current status,high current message,low current status,low current message>
Default:
Disabled
Options:
0 = Disabled 1 = Enabled
High Current Message Definition:
This message is output whenever the laser current exceeds the factory-defined maximum.
Serial Cmd:
<K411,high current status,high current message,low current status,low current message>
Default:
HIGH_LASER
Options:
Any ASCII string up to 10 characters.
Low Current Status Definition:
The Low Current message is output whenever the laser current exceeds the factory-defined minimum. The message repeats once every 30 mimutes until the condition is eliminated.
Serial Cmd:
<K411,high current status,high current message,low current status,low current message>
Default:
Disabled
Options:
0 = Disabled 1 = Enabled
Low Current Message Definition:
This message is output whenever the laser current exceeds the factory-defined minimum.
Serial Cmd:
<K411,high current status,high current message,low current status,low current message>
Default:
LOW_LASER
Options:
Any ASCII string up to 10 characters.
MS-890 Industrial Automation Scanner User’s Manual
8-7
Page 176
Present Operating Temperature (Deg. C)
Present Operating Temperature (Deg. C) (This command is Read-Only.) Usage:
Used for setting Over Temperature Threshold and Under Temperature Threshold.
Definition:
Indicates temperature of the environment immediately outside of the scanner. A thermal sensor on the main PCB measures the internal temperature of the scanner. From this, a case-differential constant is subtracted to yield an estimated external temperature.
Serial Cmd:
Send: <K408?> Returns: <K408,current operating temp. (degrees C)>
Note: When viewing the Present Operating Temperature, allow at least 20 minutes after startup for the scanner’s inside and outside temperatures to stabilize.
8-8
MS-890 Industrial Automation Scanner User’s Manual
Page 177
Diagnostics
High Temperature Threshold A message can be defined that will display when a user-set High Temperature Threshold has been reached. The message repeats once every 30 minutes until the condition is corrected. This value is a reference to the external ambient temperature in the environment around the scanner.
High Temperature Degrees Usage:
Helps ensure that the scanner is being used within its temperature specification. Also, since hotter environments tend to shorten the life of electronics components, a user may want to set the temperature threshold closer to the nominal temperature of 25°.
Definition:
A user can set a temperature value that when exceeded will cause a high temperature message to be displayed. If High Temperature Threshold is set to zero, then the warning message will be disabled.
Serial Cmd:
<K402,status,message>
Default:
Disabled
Options:
0 = Disabled 1 = Enabled
High Temperature Message Definition:
The user can enter a message of up to 10-characters that will be displayed whenever High Temperature Threshold is exceeded.
Serial Cmd:
<K402,status,message>
Default:
HIGH_TEMP
Options:
Any 1 to 10 character ASCII string except NUL, <, or >.
MS-890 Industrial Automation Scanner User’s Manual
8-9
Page 178
Low Temperature Threshold
Low Temperature Threshold Low Temperature Degrees Usage:
Helps ensure that the scanner is being used within its temperature specification.
Definition:
The user can set a low temperature value that, whenever the ambient temperature falls below it, causes a low temperature message to be displayed. If Low Temperature Threshold is set to zero, the warning message will be disabled.
Serial Cmd:
<K403,status,message>
Default:
Disabled
Options:
0 = Disabled 1 = Enabled
Low Temperature Message Definition:
The user can enter a message of up to 10-characters that will be displayed whenever the ambient temperature falls below the Low Temperature Threshold.
Serial Cmd:
<K403,status,message>
Default:
LOW_TEMP
Options:
Any 1 to 10 character ASCII string except NUL, <, or >.
8-10
MS-890 Industrial Automation Scanner User’s Manual
Page 179
Diagnostics
Lifetime Hours A message can be defined that will be transmitted whenever the scanner’s elapsed time clock exceeds the set hours threshold. The message repeats one time every 30 minutes.
Hours Threshold Usage:
Used for setting up a preventive maintenance program.
Definition:
A user can set a time in hours that will cause a message to be sent whenever the scanner’s run time exceeds this value. The elapsed time is the time the scanner is powered up.
Serial Cmd:
<K401,hours x 10,message>
Default:
2500 (x 10 = 25,000 hours)
Options: 0 to 65534 Note: Hours entered are 1/10 of the actual hours.
Message Definition:
The user can enter a message of up to 10-characters that will be displayed whenever the hours threshold is reached or exceeded.
Serial Cmd:
<K401,hours x 10,message>
Default:
SERVICE
Options:
Any 1 to 10 character ASCII string except NUL, <, or >.
MS-890 Industrial Automation Scanner User’s Manual
8-11
Page 180
Service Message
Service Message When Service Message is enabled, a message of up to 10 ASCII characters is sent whenever the system detects that the service timer’s limit has been reached. The service timer is reset at power-on, meaning that the service timer’s limit is the amount of time since last reset. Service timer increments can be set in seconds or minutes. Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> 0 0 = Disabled 1 = Enabled
Service Message Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> SERVICE An ASCII string between 1 and 10 characters.
Threshold Serial Cmd: Default: Options:
<K409,status,service message,threshold,resolution> 300 (5 minutes) 1 to 65535
Resolution Serial Cmd: Default: Options:
8-12
<K409,status,service message,threshold,resolution> Seconds 0 = Seconds 1 = Minutes
MS-890 Industrial Automation Scanner User’s Manual