Page 81

Chapter 4 Read Cycle/Trigger New Trigger Definition:

New Trigger ends the current read cycle and initiates a new one when a new trigger occurs. New Trigger refers only to a “rising edge” trigger. With either External Edge, Serial, or Serial or Edge enabled, an edge or serial trigger ends a read cycle and initiates the next read cycle. In the case of External Level, a falling edge trigger ends the read cycle but the next read cycle does not begin until the occurrence of the next rising edge trigger. (See figure 4-1 on page 4-6 and figure 4-2 on page 4-7.)

Usage:

New Trigger is an effective way to end a read cycle when objects move past the scanner at irregular intervals (not timing dependent).

Note: When New Trigger is enabled, Laser On/Off will have no effect. When noreads occur, the laser will remain on.

Timeout or New Trigger Definition:

Timeout or New Trigger is identical to Timeout, except that a timeout or a new trigger (whichever occurs first) ends the read cycle.

Usage:

Useful in applications that require an alternative way to end the read cycle. For example, if an assembly line should stop completely or the intervals between objects are highly irregular.

Timeout Duration Timeout Duration is the time span of the read cycle and is represented in 10 mS increments. It is used in conjunction with External Edge or Serial Trigger.

Usage:

It is useful in many tightly controlled applications which require a read cycle to end before the next object appears and therefore need the flexibility of a timeout adjustment.

Serial Cmd:

<K220,end of read cycle status,timeout>

Default:

100 (Corresponds to one second or 1000 ms.)

Options:

0 to 65535. (Divide any positive number entered by 100 to determine the time in seconds.)

Note: A minimum setting of 2 is recommended. Note: Timeout or Timeout or New Trigger under End of Read Cycle must be enabled for Timeout Duration to take effect.

MS-880 Industrial Long Range Scanner User’s Manual

4-15

4–Read Cycle/Trig-

Definition:

Page 82

Multilabel

Multilabel Definition:

Multilabel allows the user to define up to 12 bar code labels that can be read in a single read cycle.

Usage:

Multilabel is commonly used in shipping applications where a shipping label contains individual bar codes for part number, quantity, etc. This feature allows one trigger to pick up all the labels. AIAG and UCC/EAN128 are two application standards that address this need.

Conditions:

The following conditions apply: 1. Each bar code label must be different to be read. 2. The maximum number of characters in a read cycle is 32,520 for all labels. 3. The maximum number of characters the scanner can transmit is calculated by: Preamble + maximum number of labels * (aux id + symbology id + maximum label length + quality output + ((number of insertion cells x cell length)+ separator) + postamble + LRC = 37,425. 4. All noread messages are posted at the end of the data string. 5. If more than one label is within the scan beam at the same time, label data may not be displayed in the order of appearance.

4–Read Cycle/Trig-

6. If Matchcode Type is set to Sequential or if Trigger is set to Continuous Read 1 Output, Number of Labels will default to 1 (if set to any number greater than 1).

Number of Labels Definition:

Number of Labels is the number of different labels that can be read in a single read cycle.

Serial Cmd:

<K222,number of labels,multilabel separator>

Default:

1

Options:

1 to 12

4-16

MS-880 Industrial Long Range Scanner User’s Manual

Page 83

Chapter 4 Read Cycle/Trigger

Multilabel Separator Definition:

The character that’s inserted between each label scanned when Multilabel is set to any number greater than 1.

Usage:

Used to delimit or separate data fields with a user defined character.

ESP:

Double-click on Separator and select a character in the popup window.

Serial Cmd:

<K222,number of labels,multilabel separator>

Default:

, (comma)

Options:

Any available ASCII character, except < > NUL.

MS-880 Industrial Long Range Scanner User’s Manual

4-17

4–Read Cycle/Trig-

Note: If Multilabel Separator has been changed to any other character than the default comma and you wish to re-define the separator as a comma, use ESP (as shown below) or the embedded menu.

Page 84

4–Read Cycle/Trig-

Multilabel

4-18

MS-880 Industrial Long Range Scanner User’s Manual

Page 85

Codes

Chapter

5 Chapter Contents Narrow Margins ...........................................................................................5-5 Symbology ID ..............................................................................................5-6 Background Color........................................................................................5-7 Code 39 .......................................................................................................5-8 Codabar.....................................................................................................5-11 Interleaved 2 of 5.......................................................................................5-14 UPC/EAN ..................................................................................................5-17 PDF417 .....................................................................................................5-20 Code 128 ...................................................................................................5-22 UCC/EAN-128 ...........................................................................................5-23 Code 93 .....................................................................................................5-26 Pharma Code ............................................................................................5-27 Autodiscriminate ........................................................................................5-29

This section describes the various bar code symbol types that can be read and decoded by the scanner. Code 39 is enabled by default. To enable all codes, right-click Autodiscrimination under Code Type in the Utilities menu and select Enable, or send a <P> serial command to the scanner from the Terminal window.1 Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands. See www.aimusa.org/standards for additional information about codes.

MS-880 Industrial Long Range Scanner User’s Manual

5-1

5–Codes

1. If using an I 2/5 label, verify that the number of characters in the label being scanned matches the code length enabled for the I 2/5 code type (default is 10 and 6). See “Interleaved 2 of 5” on page 5-14.

Page 86

Code Types by ESP

Click this button to bring up the Code Types menu.

5–Codes

To change a setting, double-click the setting and use your curser to scroll through the options.

5-2

MS-880 Industrial Long Range Scanner User’s Manual

Page 87

Chapter 5 Codes

Code Types by Serial Command old cmds new cmds

Format

Ko

K450,

<K450,narrow margins status,symbology ID status>

Kx

K451,

Code 39

Kp

K470,

Codabar

Kq

K471,

Interleaved 2 of 5

Kr

K472,

UPC/EAN

Ks

K473,

Code 128

Kt

K474,

UCC/EAN-128

Kt

K474,

Code 93

K!

K475,

PDF417

K[

K476,

<K451,background color> <K470,status,check digit status,check digit output status,large intercharacter gap,fixed code length status,fixed code length,full ASCII> <K471,status,start & stop match status,start & stop output status,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> <K472,status,check digit,check digit output,length 1,length 2,guard bar> <K473,status,EAN status,supplementals status,separator status,separator char.> <K474,status,fixed length,length...> <K474,,,,UCC/EAN-128 status,output format,separator status,separator character,application identifier parentheses,record padding> <K475,status,fixed code length status,fixed code length> <K476,status,raster sweeps before decode attempt,fixed code length status,fixed code length> <K477,status,fixed code length status,fixed code length,min. no. of bars,bar widths,fwd/rev>

Command Title Narrow Margins/ Symbology ID Background Color

Pharma Code Code Type Status Request

K477, KW?

K499? <K499?>

5–Codes

MS-880 Industrial Long Range Scanner User’s Manual

5-3

Page 88

Code Types by Embedded Menu

5–Codes

For information on accessing the embedded menus, see “Embedded Menus” on page A-23. From the Main menu, scroll down through the options until you reach the following screens:

5-4

MS-880 Industrial Long Range Scanner User’s Manual

Page 89

Chapter 5 Codes

Narrow Margins Definition:

Usage: Serial Cmd: Default: Options:

Allows the scanner to read symbols with quiet zones less than 8 times the width of the narrow bar element. “Quiet zone” is the space at the leading and trailing ends of a symbol. Each quiet zone can be as narrow as only five times the width of the narrow bar element when Narrow Margins is enabled. Used when the leading and trailing edges of the symbols are smaller than the standard margin or other objects encroach into the margins. <K450,narrow margins status,symbology identifier> Disabled 0 = Disabled 1 = Enabled

Note: Do not use Narrow Margins with Large Intercharacter Gap enabled in Code 39 or Codabar.

5–Codes

MS-880 Industrial Long Range Scanner User’s Manual

5-5

Page 90

Symbology ID

Symbology ID Definition:

Symbology ID is an AIM standard prefix character that identifies the bar code type. When enabled, the scanner analyzes and identifies the bar code symbology and adds a three character identifying prefix to the data: 1. ] (close bracket character) indicating the presence of a symbology ID 2. A, C, E, F, G, I, L, Q A = Code 39; C = Code 128 or UCC/EAN-128; E = UPC/EAN; F = Codabar; G = Code 93; I = I–2 of 5; L = PDF417; Q = Pharma Code 3. Modifier, a single number indicating the status of the check digit character:

Usage: Serial Cmd: Default: Options:

If Check Digit is not enabled, the output is 0 (Col. 1). If Check Digit and Check Digit Output are enabled, the output is as shown in Column 2. If Check Digit is enabled, but Check Digit Output is disabled (Col. 3), the output is as shown in Col. 4, which is the sum of Col. 2 and Col. 3. Used when host needs to know the symbology type and how it’s decoded. <K450, narrow margins status,symbology identifier> Disabled 0 = Disabled 1 = Enabled

Example: For Code 39, if Check Digit and Check Digit Output are both enabled, a 1 will be sent; if Check Digit Output is disabled, a 3 (sum of column 1 and column 2) will be sent. Table 5-1 Symbology Identifier Option Values Symbology

Column 1 No check character

A C C E F G I L Q

Code 39 Code 128 UCC/EAN-128 UPC/EAN Codabar Code 93 I–2 of 5 PDF417 Pharma Code

0 0 0 0 0 0 0 0 0

5–Codes

Symbology I.D.

5-6

Column 2 Check digit Output enabled 1 0 0 0 1 0 1 0 0

Column 3 Check digit Output disabled 2 0 0 0 2 0 2 0 0

Column 4 Sum of Column 2 and 3 3 0 0 0 3 0 3 0 0

MS-880 Industrial Long Range Scanner User’s Manual

FNC 1 Character in first position

1