Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 10 of 32

MS-880 Industrial Long Range Scanner User's Manual, pages 91 to 100

Pages 91 to 100 of 312

The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-880

Page 91

Chapter 5 Codes

Background Color Definition: Usage:

Allows the user to choose which symbol background (white or black) the scanner can read. If the background is darker than the symbol, then enable black background. Typically the background is white; but on PCBs for example, they can be black.

ESP:

Serial Cmd: Default: Options:

<K451, background color> White 0 = White 1 = Black

5–Codes

MS-880 Industrial Long Range Scanner User’s Manual

5-7

Page 92

Code 39

Code 39 Definition: Usage:

An alphanumeric code with unique start/stop code patterns, composed of 9 black and white elements per character, of which 3 are wide. Code 39 is considered the standard for non-retail symbology.

Code 39 Status Serial Cmd: Default:

<K470,status,check digit status,check digit output status,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> Enabled

Options:

Note: This is the only code type enabled by default. 0 = Disabled 1 = Enabled

Check Digit Status (Code 39) Serial Cmd: Default: Options:

<K470,status,check digit status,check digit output,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> Disabled 0 = Disabled 1 = Enabled

Check Digit Output (Code 39) Definition:

Usage: Serial Cmd:

5–Codes

Default: Options:

When enabled, the check digit character is read and compared along with the label data. When disabled, label data is sent without the check digit. Note: With Check Digit Output and an External or Serial trigger option enabled, an invalid check digit calculation will cause a noread message to be transmitted at the end of the read cycle. Check digit Output, added to the bar code symbol, provides additional security. <K470,status,check digit status,check digit output,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> Disabled 0 = Disabled 1 = Enabled

5-8

MS-880 Industrial Long Range Scanner User’s Manual

Page 93

Chapter 5 Codes

Large Intercharacter Gap (Code 39) Definition: Usage:

Serial Cmd: Default: Options:

When enabled, the scanner can read symbols with gaps between bar code characters that exceed three times (3x) the narrow element width. Large Intercharacter Gap is helpful for reading symbols that are printed out of specification. Caution: Do not use Large Intercharacter Gap with Narrow Margins enabled since a large intercharacter gap (over 3x) could cause a narrow margins (5x) to be interpreted as an intercharacter gap. <K470, status,check digit status,check digit output,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> Disabled 0 = Disabled 1 = Enabled

Fixed Code Length Status (Code 39) Definition: Serial Cmd: Default: Options:

When enabled the scanner will check the label length against the code length field. If disabled any length would be considered a valid label. <K470, status,check digit status,check digit output,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> Disabled 0 = Disabled 1 = Enabled

Fixed Code Length (Code 39) Definition: Usage: Serial Cmd: Default: Options:

Specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check digit characters). The scanner ignores any code not having the specified length. Fixed Code Length helps prevent truncations and increases data integrity by ensuring that only one label length will be accepted. <K470, status,check digit status,check digit output,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> 10 1 to 128

5–Codes

MS-880 Industrial Long Range Scanner User’s Manual

5-9

Page 94

Code 39

Full ASCII Set (Code 39 Definition:

Usage:

Serial Cmd:

5–Codes

Default: Options:

Standard Code 39 encodes 43 characters; zero through nine, capital “A” through capital “Z”, minus symbol, plus symbol, forward slash, space, decimal point, dollar sign and percent symbol. When Full ASCII Set is enabled, the scanner can read the full ASCII character set, from 0 to 255. Must be enabled when reading characters outside the standard character set (0-9, A-Z, etc.) User must know in advance whether or not to use Full ASCII Set option. Since Full ASCII Set requires two code words to encode one character, it is less efficient. <K470,status,check digit status,check digit output,large intercharacter gap,fixed code length status,fixed code length,full ASCII set> Disabled 0 = Disabled 1 = Enabled

5-10

MS-880 Industrial Long Range Scanner User’s Manual

Page 95

Chapter 5 Codes

Codabar Definition: Usage:

Codabar is a 16-character set (0 through 9, and the characters $, :, /, ., +, and –) with start/stop codes and at least two distinctly different bar widths. Used in photo-finishing and library applications. Formerly used in some medical applications but not typically used in newer applications.

Codabar Status Serial Cmd: Default: Options:

<K471,status,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> Disabled 0 = Disable 1 = Enabled

Start & Stop Match (Codabar) Definition: Usage: Serial Cmd: Default: Options:

Requires the Codabar start and stop characters (a, b, c, or d) to match before a valid read can occur. Used to increase security of symbology. <K471,status,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> Enabled 0 = Disabled 1 = Enabled

Start & Stop Output (Codabar) Definition: Usage: Serial Cmd: Default: Options:

Causes the start and stop characters to be transmitted with bar code data. Used to verify matching. <K471,status,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> Enabled 0 = Disabled 1 = Enabled

5–Codes

MS-880 Industrial Long Range Scanner User’s Manual

5-11

Page 96

Codabar

Large Intercharacter Gap (Codabar) Definition: Usage:

Serial Cmd: Default: Options:

Instructs the scanner to read symbols with gaps between characters exceeding three times the narrow element width. It is helpful for reading symbols that are printed out of specification. Caution: Do not use Large Intercharacter Gap with Narrow Margins enabled since enabling Large Intercharacter Gap (over 3x) could cause a narrow margins (5x) to be interpreted as an intercharacter gap. <K471, status,start & stop match,start & stop output match,large intercharacter gap,fixed code length status,fixed fixed code length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled

Fixed Code Length Status (Codabar) Definition: Serial Cmd: Default: Options:

When enabled, the scanner will check the label length against the fixed code length field. If disabled any length would be considered a valid label. <K471, status,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled

Fixed Code Length (Codabar) Definition: Usage: Serial Cmd:

5–Codes

Default: Options:

Specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check digit characters). The scanner ignores any code not having the specified length. Fixed Code Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. <K471, status,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> 10 1 to 128

Note: Fixed Code Length Status must be enabled for Fixed Code Length to take effect. Note: Because of symbology limitations, setting Code Length to any number less than four will produce undetermined results.

5-12

MS-880 Industrial Long Range Scanner User’s Manual

Page 97

Chapter 5 Codes

Check Digit Type (Codabar) Definition: Serial Cmd: Default: Options:

Modulus 16: NW 7:

Allows the user to select the check digit type Codabar will use. <K471,status,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> Disabled 0 = Disabled 1 = Modulus 16 2 = NW 7 3 = Both Used in the photo-finishing market. Used in Japanese markets.

Check Digit Output (Codabar) Definition: Usage: Serial Cmd: Default: Options:

When enabled, the check digit character is sent along with the bar code data. When disabled, bar code data is sent without the check digit. For additional security a check digit can be added to the bar code symbol. <K471,status,start & stop match,start & stop match output,large intercharacter gap,fixed code length status,fixed code length,check digit type,check digit output> Disabled 0 = Disabled 1 = Enabled

5–Codes

MS-880 Industrial Long Range Scanner User’s Manual

5-13

Page 98

Interleaved 2 of 5

Interleaved 2 of 5 Definition:

Usage:

A dense, continuous, self-checking, numeric symbology. Characters are paired together so that each character has five elements, two wide and three narrow, representing numbers 0 through 9, with the bars representing the first character and the interleaved spaces representing the second character. (A check digit is highly recommended.) Important: You must set Code Length in order to decode I 2/5 symbols. It is has been has been popular because it is the most dense code for printing numeric characters less than 10 characters in length; however Microscan does not recommend this symbology for any new applications because of inherent problems such as truncation.

Interleaved 2 of 5 Status Serial Cmd: Default: Options:

<K472,status,check digit status,check digit output status,code length #1,code length #2,guard bar> Disabled 0 = Disabled 1 = Enabled

Check Digit Status (Interleaved 2 of 5) Definition: Usage: Serial Cmd: Default: Options:

An error correcting routine in which the check digit character is added. It is typically not used but can be enabled for additional security in applications where the host requires redundant check digit verification. <K472,status,check digit status,check digit output status,code length #1,code length #2> Disabled 0 = Disabled 1 = Enabled

Check Digit Output (Interleaved 2 of 5) Definition:

5–Codes

Serial Cmd: Default: Options:

5-14

When enabled, a check digit character is sent along with the bar code data for added data security. <K472,status,check digit status,check digit output,code length #1,code length #2,guard bar> Disabled 0 = Disabled 1 = Enabled

MS-880 Industrial Long Range Scanner User’s Manual

Page 99

Chapter 5 Codes

Code Length #1 (Interleaved 2 of 5) Definition:

Usage: Serial Cmd: Default: Options:

Allows user to define the symbol length. Because I 2/5 is a continuous code, it is prone to substitution errors. Hence, a code length must be defined and a bar code symbol must contain an even number of digits. Note: If a start, stop or check digits are used, they are not included in the code length count. With I 2/5, two code lengths can be defined. When using only one symbol length in an application, setting Code Length #2 to 0 (zero) to ensure data integrity is recommended. <K472, status,check digit status,check digit output status,code length #1,code length #2,guard bar> 10 2 to 128, even. Since I 2/5 characters are paired, code length must be set to an even number. If Check Digit is enabled, add 2 to your code length. For example, if your symbol is 10 characters plus a check digit, then enable Code Length for 12. Note: Typically, when printing an I 2/5 label with an odd number of digits, a 0 will be added as the first character. Note: If both Code Length #1 and Code Length #2 are set to 0, then I– 2 of 5 will be variable.

Code Length #2 (Interleaved 2 of 5) Definition: Usage: Serial Cmd: Default: Options:

Allows user to define a second code length for I–2 of 5. If using a second symbol, a zero or any even code length from 2 to 64 may be specified. If not using a second symbol, set Code Length #2 to 0 to ensure data integrity. <K472, status,check digit status,check digit output status,code length #1,code length #2,guard bar> 6 2 to 128, even.

MS-880 Industrial Long Range Scanner User’s Manual

5-15

5–Codes

Since I 2/5 characters are paired, code length must be set to an even number. If Check Digit is enabled, add 2 to your code length. For example, if your symbol is 10 characters plus a check digit, then enable Code Length for 12. Note: Typically, when printing an I 2/5 label with an odd number of digits, a 0 will be added as the first character. Note: If both Code Length #1 and Code Length #2 are set to 0, then I–2 of 5 will be variable.

Page 100

Interleaved 2 of 5

Guard Bar (Interleaved 2 of 5) Definition: Usage: Serial Cmd:

5–Codes

Default: Options:

A guard bar is a heavy bar, at least 2 times the width of the wide bar, surrounding the printed I 2 of 5 symbol and helping to prevent false reads. It is useful when I 2 of 5 multilabels are enabled to prevent false data output. This typically occurs with highly tilted or skewed labels. <K status,check digit status,check digit output status,code length #1,code length #2,guard bar> Disabled 0 = Disabled 1 = Enabled

5-16

MS-880 Industrial Long Range Scanner User’s Manual