Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 11 of 32

MS-880 Industrial Long Range Scanner User's Manual, pages 101 to 110

Pages 101 to 110 of 312

The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-880

Page 101

Chapter 5 Codes

UPC/EAN Definition:

Usage:

UPC (Universal Product Code) is a fixed length numeric, continuous symbology. UPC can have two or five digit supplemental bar code data following the normal code. The U.P.C., Version A (U.P.C., A) symbol is used to encode a 12 digit number. The first digit is the number system character, the next five are the manufacturer number, the next five are the product number, and the last digit is the checksum character. When enabled, the scanner will read UPC version A and UPC version E only. Used primarily in POS application in the retail industry. It is commonly used with Microscan scanners in applications in combination with Matchcode when there is a need to verify that the right product is being placed in the right packaging.

UPC Status Serial Cmd: Default: Options:

<K473,UPC status,EAN status,supplementals status,separator status,separator character,supplemental type> Disabled 0 = Disabled 1 = Enabled

EAN Status Definition:

Usage:

Serial Cmd: Default: Options:

EAN is a subset of UPC. When enabled, the scanner will read UPC version A, UPC version E, EAN 13, and EAN 8. It also appends a leading zero to UPC version A symbol information and transmits 13 digits. If transmitting 13 digits when reading UPC version A symbols is not desired, disable EAN. Note: The extra character identifies the country of origin. EAN is the European version of the UPC symbology and is used in European market applications. Note: UPC must be enabled for EAN to take effect. <K473,UPC status,EAN status,supplementals status, separator status, separator character,supplemental type> Disabled 0 = Disabled 1 = Enabled

5–Codes

MS-880 Industrial Long Range Scanner User’s Manual

5-17

Page 102

UPC/EAN

Supplementals Status (UPC/EAN) Definition:

Usage: Serial Cmd: Default: Options: Disabled: Enabled:

Required:

A supplemental is a 2 or 5 digit symbol appended to the main label. When set to Enabled or Required, the scanner reads supplemental bar code data that has been appended to the standard UPC or EAN codes. Reads Supplementals typically used in publications and documentation. <K473, UPC status,EAN status,supplementals status,separator status, separator character,supplemental type> Disabled 0 = Disabled 1 = Enabled 2 = Required UPC Supplementals will not be decoded. When enabled, the scanner will try to decode a main and a supplemental. However, if a supplemental is not decoded, at the end of the read cycle, the main will be sent by itself. The UPC main and supplemental symbols are considered to be one symbol and will be treated as such. When set to Required and either the main or supplemental symbol is not read, a single noread condition results. The UPC main and supplemental symbols are treated as one symbol. For example, if Supplementals is set to Required, Separator is enabled, and an asterisk is defined as the UPC separator character, then the data will be displayed as: MAIN * SUPPLEMENTAL.

Note: Under no circumstances will supplemental symbol data be sent without a main symbol. Note: If additional symbols - other than the main or supplemental - will be read in the same read cycle, Number of Labels should be set accordingly.

Separator Status (UPC/EAN) Definition: Usage: Serial Cmd:

5–Codes

Default: Options:

Allows the user to insert a character between the standard UPC or EAN code and the supplemental code when Supplementals is set to Enabled or Required. Allows user to distinguish between the main and Supplemental symbols. <K473, UPC status,EAN status,supplementals status,separator status,separator character,supplemental type> Disabled 0 = Disabled 1 = Enabled

5-18

MS-880 Industrial Long Range Scanner User’s Manual

Page 103

Chapter 5 Codes

Separator Character (UPC/EAN) Definition: Usage: Serial Cmd: Default: Options:

Allows the user to change the separator character from a comma to a new character. As required by the application. <K473,UPC status,EAN status,supplementals status,separator status,separator character,supplemental type> , (comma) Any ASCII character

Note: If Separator Character has been changed to any other character and you wish to re-define the separator as a comma, you will need to use ESP or the embedded menu. Note: Whenever Separator Character is defined as a comma (,) sending a <K473,?> command will return the current definitions including the separator character comma which will appear between two serial separator commas.

Supplementals Type (UPC/EAN) Definition: Usage: Serial Cmd: Default: Options: Both: 2 Char Only: 5 Char Only:

Allows the user to select 2 character or 5 character supplements, or both. As required by symbology used in application. <K473,UPC status,EAN status,supplementals status,separator status,separator character,supplemental type> Both 0 = Both 1 = 2 char only 2 = 5 char only Either 2 character or 5 character supplementals will be considered valid. Only two character supplementals will be considered valid. Only five character supplementals will be considered valid.

5–Codes

MS-880 Industrial Long Range Scanner User’s Manual

5-19

Page 104

PDF417

PDF417 Definition:

Usage:

Serial Cmd:

A two-dimensional, multi-row (3 to 90), continuous, variable length symbology that has high data capacity for storing up to 2700 numeric characters, 1800 printable ASCII characters, or 1100 binary character per symbol. Each symbol character consists of 4 bars and 4 spaces in a 17-module structure. Used in applications where a large amount of information (over 32 characters) needs to be encoded within a symbol, typically where the symbol is transported from one facility to another. For example, an automobile assembly line might use a single label with multiple fields of information that will be read at several stations along the way, without reference to a database. <K476, status,raster sweeps before decode attempt,fixed code length status,fixed code length>

PDF417 Status Serial Cmd: Default: Options:

<K476, status,raster sweeps before decode attempt,fixed code length status,fixed code length> Disabled 0 = Disabled 1 = Enabled

Fixed Code Length (PDF417) Definition:

5–Codes

Usage:

When enabled, the PDF label must contain the same number of characters as the code length setting before it can be considered a good decode. The scanner will ignore any code not having the specified length. Used to increase data integrity by ensuring that only one label length will be accepted.

5-20

MS-880 Industrial Long Range Scanner User’s Manual

Page 105

Chapter 5 Codes Fixed Code Length Status (PDF417) Serial Cmd: Default: Options:

<K476, status,raster sweeps before decode attempt,fixed code length status,fixed code length> Disabled 0 = Disabled 1 = Enabled

Fixed Code Length (PDF417) Definition: Serial Cmd: Default: Options:

Specifies the exact number of characters the scanner will recognize. <K476, status,raster sweeps before decode attempt,fixed code length status,fixed code length> 10 1 to 2710

Note: Fixed Code Length Status must be enabled for Fixed Code Length to take effect.

5–Codes

MS-880 Industrial Long Range Scanner User’s Manual

5-21

Page 106

Code 128

Code 128 Definition: Usage:

A very dense alphanumeric symbology. It encodes all 128 ASCII characters, it is continuous, has variable length, and uses multiple element widths measured edge to edge. Code 128 is a smaller code useful in applications with tight spots and high security needs.

Code 128 Status Serial Cmd: Default: Options:

<K474, status,fixed code length status,fixed code length> Disabled 0 = Disabled 1 = Enabled

Fixed Code Length Status (Code 128) Definition: Serial Cmd: Default: Options:

When enabled the scanner will check the label length against the code length field. If disabled any length would be considered a valid label. <K474, status,fixed code length status,fixed code length> Disabled 0 = Disabled 1 = Enabled

Fixed Code Length (Code 128) Definition: Usage: Serial Cmd: Default: Options:

It specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check digit characters). The scanner ignores any code not having the specified length. Fixed Code Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. <K474, status,fixed code length status,fixed code length> 10 1 to 128

5–Codes

Note: Fixed Code Length Status must be enabled for Fixed Code Length to take effect.

5-22

MS-880 Industrial Long Range Scanner User’s Manual

Page 107

Chapter 5 Codes

UCC/EAN-128 Definition: Usage:

A subset of Code 128, with extended features. See the Uniform Code Council, Inc. at www.uc-council.org. Used as a standard for shipping labels.

Note: Code 128 must be Enabled for UCC/EAN-128 to function.

UCC/EAN-128 Status Serial Cmd:

Default: Options: Enabled: Required:

<K474,,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Note: Code 128 serial command fields for K474 precede UCC/EAN-128. Disabled 0 = Disabled 1 = Enabled 2 = Required If Enabled, the scanner can read labels with or without a function 1 character in the first position. If set to Required, the label must have a function 1 in the first position and conform to EAN format in order to decode the bar code symbol.

Output Data Format (UCC/EAN-128) Definition: Usage: Serial Cmd: Default: Options: Standard: Application Record:

Note: If an illegal Application Record format is detected, the scanner will process it as a noread and output a noread message (if enabled).

MS-880 Industrial Long Range Scanner User’s Manual

5-23

5–Codes

Offers an option between Standard UCC/EAN-128 and Application Record format. Application Record is useful in applications in which the software can utilize application record formatting to help automate the processing of its UCC/EAN-128 data. <K474,,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Standard 0 = Standard 1 = Application Record In Standard UCC/EAN-128 application identifiers and data fields are sent, but none of the formatting (separators, parentheses, padding) will be included. Application Record is a variation of UCC/EAN-128 that allows the user to define separators between data fields, enclose application identifiers in parentheses, and enable padding (zeros) for variable length fields.

Page 108

UCC/EAN-128

Application Record Separator Status (UCC/EAN-128) Definition: Serial Cmd: Default: Options:

When enabled, a separator character is inserted between application records. <K474,,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enable

Note: Output Format must be set to Application Record before this parameter can take effect.

Application Record Separator Character (UCC/EAN-128) Definition: Serial Cmd: Default: Options:

Allows the user to define an ASCII character as an application record separator. <K474, ,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> , (comma) User Defined ASCII character

Note: Output Format must be set to Application Record before this parameter can take effect.

Application Record Brackets (UCC/EAN-128) Definition: Serial Cmd: Default: Options:

When enabled, parentheses ( ) are added to enclose application identifiers. <K474, ,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enabled

5–Codes

Note: Output Format must be set to Application Record before this parameter can take effect.

5-24

MS-880 Industrial Long Range Scanner User’s Manual

Page 109

Chapter 5 Codes

Application Record Padding (UCC/EAN-128) Definition:

Serial Cmd: Default: Options:

Padding is the insertion of zeros to make up the maximum length of a variable application record data field, except for the last field which does not require padding. When enabled, padding is included. When disabled, padding is omitted. Note: Padding is never added to fixed length fields or to the last data field of a label. Enabling or disabling Record Padding will have no effect on these. <K474,,,,UCC/EAN-128 status,output format,application record separator status,application record separator character,application record brackets,application record padding> Disabled 0 = Disabled 1 = Enabled

Note: Output Format must be set to Application Record before this parameter can take effect.

5–Codes

MS-880 Industrial Long Range Scanner User’s Manual

5-25

Page 110

Code 93

Code 93 Definition:

Usage:

Code 93 is a variable length, continuous symbology employing four element widths. Each Code 93 character has nine modules that may be either black or white. Each character contains three bars and three spaces. Used occasionally in clinical industry.

Code 93 Status Serial Cmd: Default: Options:

<K475, status,fixed code length status,fixed code length> Disabled 0 = Disabled 1 = Enabled

Fixed Code Length Status (Code 93) Definition: Serial Cmd: Default: Options:

When enabled the scanner will check the label length against the code length field. If disabled any length would be considered a valid label. <K475, status,fixed code length status,fixed code length> Disabled 0 = Disabled 1 = Enabled

Fixed Code Length (Code 93) Definition: Usage:

5–Codes

Serial Cmd: Default: Options:

Specifies the exact number of characters that the scanner will recognize (this does not include start and stop and check digit characters). The scanner ignores any code not having the specified length. Fixed Code Length helps prevent truncations and increases data integrity by ensuring that only one symbol length will be accepted. <K475, status,fixed code length status,fixed code length> 10 1 to 128

5-26

MS-880 Industrial Long Range Scanner User’s Manual