Page 71

Chapter 4 Read Cycle/Trigger

Continuous Read 1 Output Definition:

In Continuous Read 1 Output the scanner self-triggers whenever it decodes a new bar code label or a timeout occurs. If End Of Read Cycle is set to Timeout and the label doesn't change, the scanner will repeat the output at the end of each timeout period. For example, if Timeout is set to one second, the scanner sends the label data immediately and repeats the output at intervals of one second for as long as the label continues to be scanned. If End Of Read Cycle is set to New Trigger, the scanner will send the current label data immediately, but send it only once. A new label appearing in the scanner’s range will be read and sent immediately provided it is not identical to the previous label read.

Usage:

Continuous Read 1 Output can be useful in applications where it is not feasible to use a trigger and all succeeding labels contain different information. It is also effective in applications where the objects are hand presented.

Serial Cmd:

<K200,1>

Caution: In automated environments, Continuous Read 1 Output is not recommended because there is no one to verify that a label was missed. Note: If Trigger is set to Continuous Read 1 Output, Number of Labels will default back to 1 (if set to any number greater than 1).

4–Read Cycle/Trig-

MS-880 Industrial Long Range Scanner User’s Manual

4-5

Page 72

Trigger Mode

External Trigger Level Definition:

External Trigger Level allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. The read cycle endures until the object moves out of the sensor range and the active trigger state changes again.

Usage:

This mode is effective in an application where the speeds of the conveying apparatus are variable and the time the scanner spends scanning each object is not predictable. It also allows the user to determine if a noread has occurred. Initiate Read Cycle:

Object # 1, moving in front of the detector beam, causes a change in the trigger state, initiating the read cycle. Associated waveforms assume External Trigger State is set to Active On.

End Read Cycle:

The same object, moving out of the detector beam, causes another change in the trigger state, ending the read cycle.

Figure 4-1 Trigger Level

4–Read Cycle/Trig-

Serial Cmd:

<K200,2>

Important: Level and Edge apply to the active logic state (Active Off (IOFF) or Active On (ION)) that exists while the object is in a read cycle, between the rising edge and falling edge. Rising edge is the trigger signal associated with the appearance of an object. Falling edge is the trigger signal associated with the subsequent disappearance of the object. Note: In External Trigger Level, sending a Non-delimited Start Serial Character will start a read cycle and sending a Non-delimited Stop Serial Character will end it. See “Start and End Trigger Characters (non-delimited)” in chapter 4.

4-6

MS-880 Industrial Long Range Scanner User’s Manual

Page 73

Chapter 4 Read Cycle/Trigger

External Trigger Edge Definition:

External Trigger Edge, as with Level, allows the read cycle (active state) to begin when a trigger (change of state) from an external sensing device is received. However, the passing of an object out of sensor range does not end the read cycle. The read cycle ends with a good read output or, depending on End of Read Cycle setting, a timeout or new trigger occurs.

Usage:

This mode is highly recommended in any application where conveying speed is constant or if spacing, object size, or timeouts are consistent. Initiate Read Cycle:

Object # 1, moving in front of the detector beam, causes a change in the trigger state, initiating the read cycle.

Initiate Second Read Cycle:

Associated waveforms assume External Trigger State is set to Active On.

Object # 2, moving in front of the detector beam, causes another change in the trigger state. This signal initiates a new read cycle and ends the previous read cycle unless Timeout is enabled and a good read or timeout has not occurred.

Figure 4-2 Trigger Edge Serial Cmd:

<K200,3>

MS-880 Industrial Long Range Scanner User’s Manual

4-7

4–Read Cycle/Trig-

Important: Level and Edge apply to the active logic state (Active Off (IOFF) or Active On (ION)) that exists while the object is in a read cycle, between the rising edge and falling edge. Rising edge is the trigger signal associated with the appearance of an object. Falling edge is the trigger signal associated with the subsequent disappearance of the object. Note: In External Trigger Edge, sending a Non-delimited Start Serial Character will start a read cycle; however a Non-delimited Stop Serial Character has no effect. See “Start and End Trigger Characters (non-delimited)” on page 4-10.

Page 74

Trigger Mode

Serial Data Definition:

In Serial Data, the scanner accepts an ASCII character from the host or controlling device as a trigger to start a read cycle. A Serial Data trigger behaves the same as an External Edge trigger. Serial commands are entered inside corner brackets, such as <t>.

Usage:

Serial Data is effective in a highly controlled environment where the host knows precisely when the object is in the scan zone. It is also useful in determining if a noread has occurred.

Serial Cmd:

<K200,4>

Serial Data or External Edge Definition:

In this mode the scanner accepts either a serial ASCII character or an external trigger pulse to start the read cycle.

Usage:

Serial Data or External Edge is seldom used but can be useful in an application that primarily uses an external sensing device but occasionally needs to be manually triggered. An auxiliary terminal can be connected to the aux port so the user can send the serial trigger character through the scanner to the host.

Serial Cmd:

<K200,5>

4–Read Cycle/Trig-

Note: In Serial Data or External Edge, sending a Non-delimited Start Serial Character will start a read cycle; however a Non-delimited Stop Serial Character has no effect. See “Start and End Trigger Characters (non-delimited)” on page 4-10.

Network Trigger Definition:

A trigger can also be sent over the network if installed. A network attribute triggers a pulse that performs similarly to External Edge.

Usage:

Network Trigger allows a network command to be entered from a host networked to the scanner. See the MS-880 Network Protocol Card User’s Manual (83-110015).

Serial Cmd:

<K200,6>

4-8

MS-880 Industrial Long Range Scanner User’s Manual

Page 75

Chapter 4 Read Cycle/Trigger

Trigger Filter Duration Definition:

Trigger Filter Duration can prevent trigger bounce from falsely triggering the scanner by limiting the time in which trigger pulses can be received.

Usage:

Trigger Filter Duration is useful where trigger bounce could cause false triggers.

Serial Cmd:

<K200,trigger mode,trigger filter duration>

Default:

320 (x 31.25 µs = 10ms)

Options:

0 to 65535 (corresponding to 0 to 2.048 s in 31.25 µs steps)

Good Decode Reads Definition:

The number of decodes (from 1 to 31) required per label before a label’s decoded data is sent. It requires the scanner to successfully decode a label a designated number of times (not necessarily consecutively) before it is sent. If it doesn’t achieve the number of good reads during the read cycle, then a noread will be sent. Note: Higher settings will decrease throughput speed.

Usage:

This is a very useful feature to increase reliability of reads for symbologies that do not have internal error checking such as Pharmacode.

Serial Cmd:

<K221,decodes before output>

Default:

1

Options:

1 to 31

MS-880 Industrial Long Range Scanner User’s Manual

4-9

4–Read Cycle/Trig-

Note: When setting up, be sure to determine if the scanner’s scan rate is capable of scanning your longest label the required number of times.

Page 76

Serial Trigger

Serial Trigger Definition:

A single ASCII host serial trigger character that initiates the read cycle. Serial Trigger Character is considered an on-line host command and requires the same command format as all host commands: that is, to be entered within angle brackets delimiters < >.

Serial Trigger Character (delimited) Definition:

A delimited trigger character is one that either starts or ends the read cycle and is enclosed by delimiters such as < >.

Usage:

Allows the user to define the trigger character that initiates the read cycle.

Serial Cmd:

<K201,serial trigger character>

Default:

^] (corresponds to <GS> displayed in the embedded menu)

Options:

Any single ASCII character, including control characters, except NUL (00H), an existing host command character, or an on-line protocol character. Control characters entered on the command line are displayed in the menu as mnemonic characters.

Note: Serial Data or Serial Data or Edge triggering mode must be enabled for Serial Trigger Character to take effect.

4–Read Cycle/Trig-

Start and End Trigger Characters (non-delimited) Definition:

A non-delimited trigger character is one that either starts or ends the read cycle and is NOT enclosed by delimiters such as < >. Both Start and End non-delimited characters can be defined and will function according to the trigger event, as follows: When defining Start and End trigger characters, the following rules apply: • In External Edge the scanner looks only for the Start Trigger Character and ignores any End Trigger Character that may be defined. • In External Level, the Start Trigger Character begins the read cycle and End Trigger Character ends it. Note that even after a label has been decoded and the label data transmitted, the scanner remains in External Level trigger read cycle until a Stop character is received. • In Serial Data & Edge trigger mode, command, either a Start Trigger Character or a hardware trigger can start an Edge trigger read cycle.

Usage:

4-10

It is useful in applications where different characters are required to start and end a read cycle. MS-880 Industrial Long Range Scanner User’s Manual

Page 77

Chapter 4 Read Cycle/Trigger Note: Start and End serial trigger characters can be sent through host ports or aux ports, but not the IrDA port.

Start Serial Trigger Character (non-delimited) Definition:

A single ASCII host serial trigger character that starts the read cycle and is not enclosed by delimiters such as < and >.

Serial Cmd:

<K229,start trigger character>

Default:

Null (disabled)

Options:

Two hex digits representing an ASCII character except <, >, XON and XOFF.

Note: Serial Data or Serial Data or Edge triggering mode must be enabled for Serial Trigger Character to take effect.

End Serial Trigger Character (non-delimited) Definition:

A single ASCII host serial trigger character that ends the read cycle and is not enclosed by delimiters such as < and >.

Usage:

It is useful in applications where different characters are required to start and end a read cycle.

Serial Cmd:

<K230,end trigger character>

Default:

Null (disabled)

Options:

Two hex digits representing an ASCII character except <, >, XON and XOFF.

Note: Serial Data or Serial Data or Edge triggering mode must be enabled for Serial Trigger Character to take effect.

4–Read Cycle/Trig-

MS-880 Industrial Long Range Scanner User’s Manual

4-11

Page 78

External Trigger State

External Trigger State Definition:

When enabled for Active On (ION) (Positive) the triggering device imposes a current on the optoisolator to activate the read cycle. When enabled for Active Off (IOFF) (Negative) the triggering device interrupts the current to the optoisolator to activate the read cycle.

Usage:

Allows users to select the trigger state that will operate with their systems. (If using the Microscan object detector, use Active Off.)

Serial Cmd:

<K202,external trigger state>

Default:

Active On (Positive)

Options:

0 = Active Off (Negative) 1 = Active On (Positive)

4–Read Cycle/Trig-

Note: External Level, External Edge, or Serial Data or Edge trigger mode must be enabled for External Trigger to take effect.

4-12

MS-880 Industrial Long Range Scanner User’s Manual

Page 79

Chapter 4 Read Cycle/Trigger

End of Read Cycle Definition:

The read cycle is the time during which the scanner will attempt to read and decode a bar code symbol.

Serial Cmd:

<K220,end of read cycle status,timeout>

End of Read Cycle Status A read cycle can be terminated by a new trigger, a timeout, or a combination of both.

ESP:

Double-click on End of Read Cycle Mode and make a selection.

Serial Cmd:

<K220, end of read cycle status,timeout>

Default:

Timeout

Options:

0 = Timeout 1 = New Trigger 2 = Timeout & New Trigger

Note: When operating in Continuous Read or Continuous Read 1 Output, the scanner is always in the read cycle.

MS-880 Industrial Long Range Scanner User’s Manual

4-13

4–Read Cycle/Trig-

Definition:

Page 80

End of Read Cycle Timeout Definition:

Timeout ends the read cycle, causing the scanner to stop reading labels and send the label data or noread message when the time set in Timeout elapses (times out), if When to Output is set to End of Read Cycle. If in Continuous Read 1 Output, a timeout initiates a new read cycle and allows the same label to be read again. With either External Edge, Serial Data, or Serial Data & Edge enabled, a timeout ends the read cycle and label data or a noread message is sent to the host. With External Level enabled, the read cycle does not end until the falling edge trigger or a timeout occurs. The next read cycle does not begin until the next rising edge trigger. Typically used with Serial or Edge and Continuous One. It is effective in highly controlled applications when the maximum length of time between objects can be predicted. It assures that a read cycle ends before the next bar-coded object appears, giving the system extra time to decode and transmit the data to the host.

4–Read Cycle/Trig-

Usage:

4-14

MS-880 Industrial Long Range Scanner User’s Manual