Intercharacter Delay Definition:
The time interval in milliseconds between individual characters transmitted from the scanner to the host.
Usage:
Intercharacter Delay is only used where a host cannot receive data quickly enough and there is enough time between labels to allow data to be completely transferred. It is rarely used since any setting other than zero will slow down communications. For example, a 200 setting will result in a 1/5 second delay between each character that is transmitted.
Serial Cmd:
<K144,intercharacter delay> Example: To change Intercharacter Delay to 30 ms, send <K144,30>.
Default:
0
Options:
0 to 255 (in milliseconds). Zero (0) causes no delay between characters.
3–Protocol
MS-880 Industrial Long Range Scanner User’s Manual
3-11
Page 62
Output Data Format
Output Data Format Up to four user defined ASCII characters, including control characters can be defined and added to the front or end of the data string that is sent from the scanner to the host. Note: See also Chapter 13, “Output Format and Filtering”.
Preamble Characters
3–Protocol
Preamble Status Definition:
Define a one to four character data string that can be added to the front of the decoded data.
Usage:
Useful for identifying and controlling incoming data. For example, defining the preamble as a carriage return and a line feed causes each decoded message to be displayed of on its own line.
Serial Cmd:
<K141,status,preamble character(s)>
Default:
Disabled
Options:
0 = Disabled
1 = Enabled (within any protocol)
Preamble Character(s) Serial Cmd:
<K141,status,preamble character(s)>
Default:
^M corresponding to: carriage return/null/null/null.
Options:
Within a Serial Command To enter control characters within a serial command, hold down the control key while typing the desired character. Example: <K141,1,CNTL-m> to enter ^M
Within an Embedded Menu Control characters entered on the command line are displayed in the menu as mnemonic characters, such as: <CR><NUL><NUL><NUL>. To enter a control character from within an embedded menu, first type in a space (with the space key). This has the effect of allowing the control key to be recognized as a part of the control character. Next hold down the control key while typing the desired character. Example: Space CNTL-m to enter ^M.
3-12
MS-880 Industrial Long Range Scanner User’s Manual
Page 63
Chapter 3
Protocol
Postamble Characters Postamble Status Definition:
Allows the user to enable or disable up to four postamble character(s) that can be added to the end of the decoded data.
Usage:
Useful for identifying and controlling incoming data. For example, defining the postamble as a carriage return and a line feed causes each decoded message to be displayed of on its own line.
Serial Cmd:
<K142,status,postamble character(s)>
Default:
Enabled
Options:
0 = Disabled
1 = Enabled (within any protocol)
Postamble Character(s) <K142,status,postamble character(s)>
Default:
^M^J. Corresponds to carriage return/line feed/null/null, as displayed in the menu.
Options:
Up to four user-defined ASCII character, including control characters.
Within a Serial Command To enter control characters within a serial command, hold down the control key while typing the desired character. Example: <K142,1,CNTL-m CNTL-j> to enter ^M^J.
Within an Embedded Menu Control characters entered on the command line are displayed in the menu as mnemonic characters, such as: <CR><LF><NUL><NUL> To enter a control character from within an embedded menu, first type in a space (with the space key). This has the effect of allowing the control key to be recognized as a part of the control character. Next hold down the control key while typing the desired character. Example: Space CNTL-m Space CNTL-j to enter ^M^J.
MS-880 Industrial Long Range Scanner User’s Manual
3-13
3–Protocol
Serial Cmd:
Page 64
Auxiliary/Configuration System Data
Auxiliary/Configuration System Data Note: Do not use this with Daisy Chain operation.
Auxiliary Status Note: This command only applies if the Aux Mode is set to Command Processing. See “Command Processing Mode” on page 2-13. Definition:
When enabled, system data, including decoded data and diagnostic warning messages, will be routed to the aux port.
Usage:
To check label data and error messages via the aux port.
Serial Cmd:
<K146,aux status,config status>
Default:
Disabled
Options:
0 = Disabled, 1 = Enabled
3–Protocol
Configuration Status Definition:
When enabled, system data, including decoded data and diagnostic warning messages, will be routed to the 9-pin configuration port or if active to the IrDA port.
Usage:
To check label data and error messages via the configuration port.
Serial Cmd:
<K146,aux status,config status>
Default:
Disabled
Options:
0 = Disabled, 1 = Enabled
When using the 9-pin configuration port it is important to remember to enable this command.
3-14
MS-880 Industrial Long Range Scanner User’s Manual
Page 65
Chapter 3
Protocol
Network Client Network Client is enabled whenever a network protocol card is installed in the MS-880 wiring box and in conjunction with one of the following protocols:
DeviceNet Profibus-DP DataHighway Plus For configuration and installation information on the above protocols and protocol cards, see The Network Protocol Card User’s Manual, part number 83-210015.
3–Protocol
MS-880 Industrial Long Range Scanner User’s Manual
3-15
Page 66
3–Protocol
Network Client
3-16
MS-880 Industrial Long Range Scanner User’s Manual
Page 67
Chapter
Read Cycle/Trigger
4 Chapter Contents Trigger Mode ...............................................................................................4-4 Serial Trigger .............................................................................................4-10 External Trigger State ...............................................................................4-12 End of Read Cycle ....................................................................................4-13 Multilabel ...................................................................................................4-16
Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
MS-880 Industrial Long Range Scanner User’s Manual
4-1
4–Read Cycle/Trig-
Read cycles and triggering modes are at the heart of bar code scanning. After you’ve established communications and completed basic read rate testing, you will need to address the spatial and timing parameters associated with your application. In a typical operation a bar-coded item moves along a line past a scanner. A sensor or timer activates a read cycle during which the scanner actively searches for bar code symbols. You will need to decide how to initiate the read cycle and how and when to end it. This section addresses these issues.
Page 68
Read Cycle/Trigger by ESP
Click this Button to bring up the Read Cycle/Triggering menu.
4–Read Cycle/Trig-
To change a setting, double-click the setting and use your curser to scroll through the options.
Read Cycle/Trigger by Serial Command Command Title Triggering Mode Serial Trigger Character External Trigger State End of Read Cycle Decodes Before Output Start Serial Trigger Character Stop Serial Trigger Character Multilabel
4-2 old cmds Kg Ki Kh Km
KL new cmds K200, K201, K202, K220, K221, K229, K230, K222,
Format <K200,trigger mode,filter time> <K201,character> <K202,external trigger state> <K220,end of read cycle status,timeout> <K221,decodes before output> <K229,start trigger character> <K230,end trigger character> <K222,number of labels,multilabel separator>
MS-880 Industrial Long Range Scanner User’s Manual
Page 69
Chapter 4 Read Cycle/Trigger
Read Cycle/Trigger by Embedded Menu For information on accessing the embedded menus, see “Embedded Menus” on page A-23. From the Main menu, scroll down through the options until you reach the following screen:
4–Read Cycle/Trig-
MS-880 Industrial Long Range Scanner User’s Manual
4-3
Page 70
Trigger Mode
Trigger Mode Note: When doing autocalibration or read rate testing, the current trigger setting will be disregarded. Definition:
The type of trigger event that will initiate the read cycle.
Serial Cmd:
<K200,trigger mode,trigger filter duration>
Default:
Continuous Read
Options:
0 = Continuous Read 1 = Continuous Read 1 Output 2 = External Level 3 = External Edge
4 = Serial Data 5 = Serial Data & External Edge 6 = Network Trigger 7 = User Defined Read Cycle
Continuous Read In Continuous Read, trigger input options are disabled, the scanner is always in the read cycle, and it will attempt to decode and transmit every scan crossing a label. When To Output and Noread options have no affect on Continuous Read.
Usage:
Continuous Read is useful in testing bar code label readability or scanner functions. It is not recommended for normal operations.
Serial Cmd:
<K200,0>
4–Read Cycle/Trig-
Definition:
4-4
MS-880 Industrial Long Range Scanner User’s Manual