MS-880 Industrial Long Range Scanner User's Manual, pages 251 to 260

Pages 251 to 260 of 312

The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-880

Page 251

Chapter 17 Utilities

Checksum You can send a request to the scanner for part numbers, checksums, boot code, and application and code.

By ESP

By Serial Command Upon sending <!> the scanner returns three 4-digit hex numbers that are displayed under Check Sum. Checksums verify a scanner’s flash memory. Individual checksums for Boot Code and Application Code are returned when their respective commands <!b> and <!a> are sent.

MS-880 Industrial Long Range Scanner User’s Manual

17-9

17–Utilities

You can access Checksum from the Utilities menu. Right-click the appropriate option and select Request to see the associated part number or check sum number.

Page 252

Read Rate

Read Rate You can do a read rate test for decode rate or percent by ESP or serial command.

By ESP You can access Read Rate from the Utilities menu.

17–Utilities

To start or end a read rate test, right-click Read Rate and select Start or Stop. To change from percent read rate to decodes per second, right-click Read Rate and make the selection.

By Serial Command Enter Single Label Decodes/Second Test Sending <C> instructs the scanner to transmit the decodes per second and label data (if any). The decode rate can vary dramatically due to the angle and location of the label in relation to the scan line. This test is very useful in aligning and positioning the scanning device during installation.

Enter Single Label Percent Test Sending <Cp> instructs the scanner to transmit the percentage of decodes and any scanned label data.

Enter Multilabel Percent Test Sending <Cm> instructs the scanner to transmit the percentage of scans decoded and label data (if any) for multiple labels.

Enter Multilabel Decode Rate Test Sending <Cs> instructs the scanner to transmit the decode rate and label data (if any) for multiple labels.

17-10

MS-880 Industrial Long Range Scanner User’s Manual

Page 253

Chapter 17 Utilities Enter Percent PDF Read Rate Test Sending <CPDF> instructs the scanner to transmit the number of decodes per second on the full PDF label. This test includes both capture and decode and translation time. Note that the output format of the data is done as a running average of 750 mS windows. This means that you can remove the label from the view of the scanner and it will continue to transmit some history of the label for a few outputs.

End Read Rate Test Sending <J> ends both the Percent test and the Decodes/Second test for both single and multi-label. Sending the <a1> check box will cause PDF417 symbology data to be prefaced with information consisting of error correction level, number of rows, number of columns, number of informative code words and the number of data characters. Explanation of above PDF Info sample of a PDF417: Level = 5 tells you that the error correction level is level 5. There are 13 rows and 6 columns. There are 14 info code words, and 16 characters in the data. This feature can be disabled by using the exit read rate command <J>.

MS-880 Industrial Long Range Scanner User’s Manual

17-11

17–Utilities

Enable PDF Information

Page 254

Device Control

Device Control You can control laser scanning by ESP or serial command.

By ESP You can access Device Control from the Utilities menu.

17–Utilities

For any of the Device Control commands, right-click on the command and make your selection.

By Serial Command Enable Laser Scanning Sending <H> will turn the laser on continuously. Note: Enable Laser Scanning does not relate to Laser On/Off command.

Disable Laser Scanning Sending <I> will turn the laser off. This feature is useful during extended periods of time when no bar code labels are being scanned or the scanner is being configured. Disabling laser scanning will not affect any downloaded commands to the scanner. Note: Disable Laser Scanning does not relate to Laser On/Off, which when enabled also turns off the laser but only between read cycles.

Motor On Sending <KE> turns the spinning mirror and raster mirror motors on (if not already running). Note: the spinning mirror reaches full speed after a short time delay.

Motor Off Sending <KF> turns the spinning mirror motor off. This command is useful for long idle periods. Note: Laser turns off whenever motor is off.

17-12

MS-880 Industrial Long Range Scanner User’s Manual

Page 255

Chapter 17 Utilities Output #1 Sending <L1> activates the link between Output 1(+) and Output 1 (–) of the 25-pin host connector (regardless of Master Label or Output 1 status).

Output #2 Sending <L2> activates the link between Output 2(+) and Output 2 (–) of the 25-pin host connector (regardless of Master Label or Output 2 status).

Output #3 Sending <L3> activates the link between Output 3(+) and Output 3 (–) of the 25-pin host connector (regardless of Master Label or Output 3 status).

17–Utilities

Code Type See also “Autodiscriminate” on page 5-29 for a discussion of Utility commands for Code Types and Autodiscrimination. Default: Options:

Code 39 (only) <P> Enables most code types. <Q> Enable Code 39 only <R> Enable Codabar only <S> Enable I 2/5 only

Defaulting/Saving/Initializing See Appendix I, “Defaulting/Saving/Initializing” on page A-24.

MS-880 Industrial Long Range Scanner User’s Manual

17-13

Page 256

17–Utilities

Defaulting/Saving/Initializing

17-14

MS-880 Industrial Long Range Scanner User’s Manual

Page 257

Appendices

Chapter Contents

MS-880 Industrial Long Range Scanner User’s Manual

Appendices

Appendix A General Specifications ....................................................... A-2 Appendix B Electrical Specifications ..................................................... A-6 Appendix C IrDA Configuration Port.................................................... A-13 Appendix D IrDA/Ir Comm for Palm Pilot ............................................ A-15 Appendix E Serial Configuration Commands ...................................... A-16 Appendix F Serial Command Format .................................................. A-19 Appendix G ASCII Table ..................................................................... A-21 Appendix H Embedded Menus............................................................ A-23 Appendix I Defaulting/Saving/Initializing ............................................. A-24 Appendix J Position Scanner and Bar Code ....................................... A-28 Appendix K Position Object Detector .................................................. A-29 Appendix L Test Decode Rate ............................................................ A-30 Appendix M Formulas for Number of Decodes ...................................... A-31 Appendix N Operational Tips .............................................................. A-35 Appendix O Interface Standards ......................................................... A-36 Appendix P Multidrop Communications .............................................. A-38 Appendix Q Glossary of Terms ........................................................... A-43

A-1

Page 258

Appendix A

Appendix A, General Specifications Key Features • Multiple label and symbology reading Centerline of scan window

• Extra-long scanning range to 90 inches • Autofocusing • Programmable raster scanning

5.2

• IrDA (infrared) port (palm pilot compatible) • 3 programmable outputs • Industrial IP65 rated enclosures

• Optional wiring box, IB-880

Appendices

Mechanical Depth: 3.5 in (88 mm) Width: 5" (127 mm) Height: 6 in. (152 mm) Weight: 5 lbs. (227 g)

4X M4 .50 MAX

6.0

1.88

Environmental Enclosure rating: IP65 for scanner and wiring box Operating temperature: 0° to 50°C Operating temperature: 0° to 40°C Storage temperature: –50° to 75°C Humidity: Up to 90% (non-condensing)

.86 .63

3.75

3.5

Emissions and Immunity General immunity for ITE equipment: EN 55024:98 General immunity for light industry: EN 50082:97 General immunity for heavy industry: EN 61000-6-2:98 Radiated and conducted emissions of ITE equipment: EN 55022:98, Class A

5.0

Figure A-1 MS-880 Scanner Dimensions

Laser Light Semiconductor visible laser diode: 650nm nominal; 780nM nominal (optional) Safety class: CDRH Class II Operating Life: 40,000 hours @25°C

A-2

MS-880 Industrial Long Range Scanner User’s Manual

Page 259

General Specifications Scanning Parameters Scanning mirror type: Rotating, 14-faceted mirror Scan rate: 400 to 1000 scans per second Scan width angle: Typically 60°; Pitch: ±50° max.; Skew: ±40° max. Label contrast: 25% min. absolute dark to light differential at 650nm wavelength Raster sweep angle: ±15° Raster sweep speed: 1 to 10 sweeps per second

Communication RS-232, RS-422/485, Daisy Chain RS-232, RS-422/485, SDS,* DeviceNet,* Profibus,* Ethernet,* daisy chain/auxiliary port capable, IrDa port** *Used in conjunction with an accessory protocol card. *The IrDa port allows communication by Palm and laptop computers.

Protocol Options with Wiring Box DeviceNet, Profibus DP, Modicon Ethernet, DH485

Code Types Appendices

Standard offering: Code 128, Code 39, Code 93, Codabar, Interleaved 2 of 5, UPC/EAN, PDF417, Pharma Code Application standards: AIAG, UCC/EAN-128

FIS Options Table A-1 MS-880 FIS Options -001 -002

MS-880 Standalone MS-880 for Wiring Box

Read Ranges Table A-2 MS-880 Read Ranges Narrow-bar-width

Scanning Distance

.0075" (.190mm)

10" to 35" (.254 to .889m)

.010" (.254mm)

10" to 44" (.254 to 1.118m)

.015" (.381mm)

10" to 74" (.254 to 1.880m)

.020" (.508mm)

10" to 90" (.254 to 2.286m)

.030" (.762mm)

10" to 100" (.254 to 2.540m)

.040" (1.020mm)

10" to 110" (.254 to 2.794m)

.050" (1.27mm)

10" to 120" (.254 to 3.048m)

MS-880 Industrial Long Range Scanner User’s Manual

A-3

Page 260

Appendix A Mounting Specifications

4X M4 .50 MAX 4X M4 .50 MAX

1.88

1.88

.88 .625

3.75

.88 .625

Front

3.75

Back

Appendices

Figure A-2 Mounting Dimensions

Beeper Beeps on output (good read, noread, match, or mismatch), serial command confirmation, on/off.

LED Indicators Table A-3 MS-880 Status Lights (on the side of the MS-880) LED POWER GOOD READ (not in read rate test) STATUS (not in read rate test) 20%, 40%, 60%, 80%, 100% NETWORK STATUS MODULE STATUS

State Status Green-On Scanner has power Green-Off No power On Scanner is ready to read Off Scanner is not ready to read On Scanner is in a read cyclea Off Scanner is not in a read cycle On Represents the percentage of good readsb This LED is only used with embedded protocols, and its function depends on the protocol used.c Same as NETWORK STATUS above.

a. In Continuous and Continuous1, the status light is always on. b. If these LEDs are flashing in a pattern and the scanner is not in a read rate test, there is an error pattern. Contact Microscan support if this occurs. c. Refer to Appendix A of the MS-880 Network Protocol User’s Manual for a breakdown of the LED modes.

A-4

MS-880 Industrial Long Range Scanner User’s Manual