The text of a manual · part 25 of 32
MS-880 Industrial Long Range Scanner User's Manual, pages 241 to 250
Pages 241 to 250 of 312
The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-880
Page 241
Chapter 16 Wiring Box Option
.40" (10.2mm)
16–Wiring Box
Mounting Plate
7.175" (18.2 mm)
2.90" (73.7mm) 2 X PE M B SO A- 86 32 -2 0 O R EQ UIVA L ENT
.413" (10.4 mm) 1.81" (46.0mm)
4.39" (11.15 mm)
Figure 16-8 Wiring Box Bottom Plate
MS-880 Industrial Long Range Scanner User’s Manual
16-9
Page 242
16–Wiring Box
Mounting Plate
16-10
MS-880 Industrial Long Range Scanner User’s Manual
Page 243
Chapter
Utilities
17 File Transfer ..............................................................................................17-5 Counters ....................................................................................................17-6 Part Number ..............................................................................................17-8 Checksum .................................................................................................17-9 Read Rate ...............................................................................................17-10 Device Control .........................................................................................17-12 Code Type ...............................................................................................17-13 Defaulting/Saving/Initializing ...................................................................17-13
Utility commands are generally commands that are performed during scanner operations to check read rates, determine read rates or perform miscellaneous operations on scanner hardware. Serial utility commands are not prefaced with a “K”and a numeric code. Nor do they require an initialization command (<A> and <Z>). They can be entered from within any terminal program or from within ESP-MP in the Terminal window or the window adjacent to the Utilities menu. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
MS-880 Industrial Long Range Scanner User’s Manual
17-1
17–Utilities
Chapter Contents
Page 244
Utilities by ESP Menu
17–Utilities
Click this button to bring up the Utilities menu.
To change a setting, right-click the setting and use your curser to scroll through the options.
Note: Utility commands are not accessible by embedded menus.
17-2
MS-880 Industrial Long Range Scanner User’s Manual
Page 245
Chapter 17 Utilities
Utilities by Serial Command Table 17-1 Summary of Utility Serial Commands Command Type
Counter Request and Clear
Read Rate
Read Rate
Device Control
Code Types Commands Trigger
Name Noread Counter Noread Counter Reset Trigger Counter Trigger Counter Reset Good Read/Match Counter Good Read/Match Counter Reset Mismatch Counter Mismatch Counter Reset Display all three Checksums of Flash memory Display Checksum for Boot Code Display Checksum for Application Code Display both Part Numbers Display Boot Code Part Number Display Application Code Part Number Enter Single Label Percent Rate Test Enter Single Label Decode Rate Test Enter Multilabel Percentage Rate Test Enter Multilabel Decode Rate Test PDF Information Exit Decode Rate and Percent Rate Test Enter Percent PDF Read Rate Test Enable Laser Scanning Disable Laser Scanning Motor On Motor Off Programmable Output 1 Programmable Output 2 Programmable Output 3 Autodiscriminate All Codes Enable Code 39 Only Enable Codabar Only Enable I 2/5 Only Serial Trigger Character
MS-880 Industrial Long Range Scanner User’s Manual
17–Utilities
Part Number Checksum/
Command <N> <O> <T> <U> <V> <W> <X> <Y> <!> <!b> <!a> <#> <#b> <#a> <Cp> <C> <Cm> <Cs> <a1> <J> <CPDF> <H> <I> <KE> <KF> <L1> <L2> <L3> <P> <Q> <R> <S> <char>
17-3
Page 246
Default/Reset/ Save
17–Utilities
Master Label
<A> <Ad> <An> <Z> <Zp> <Zd> <E> <F> <G> <Mmaster label number,data> <M?> <Mmaster label number,>
Network Status
<n>
Status Commands
<-> <?> <?1> <K?>
Reset (does not save for power-on) Default Restore Saved Settings Reset/Save (for power-on) Save Factory Settings Save/Restore Factory Defaults Enable Master Label * Disable Master Label*
Store next label scanned to database.a Enter data to database for specified label* Request master label information* Delete Master Label*
Network Status Command (See the "Network Protocol Manual" 83-110015) Input Status Scanner Status Extended Scanner Status Configuration Status a. If no number is included, the label will be saved to database number 1. *Can also be set in the configuration menu or with a serial configuration command. (See Chapter 11, “Matchcode.”)
17-4
MS-880 Industrial Long Range Scanner User’s Manual
Page 247
Chapter 17 Utilities
File Transfer File transfer is used to download application code to the scanner. Application code versions are specific to your scanner. Consult with your sales representative before downloading application code. If needed, an application code will be sent to you in the form of a *.mot file. To download application code: 1. First make sure the host is connected to your scanner. 3. In the Utilities window, right-click on File Transfer and select Download/App Code. This will open a file dialog box. 4. Navigate to the appropriate file (a *.mot file) and open the file. As application code begins to download to the scanner, the scanner will go silent, the scanner’s RDY and GD/RD LEDs will flash intermittently, and a progress indicator at the bottom of the ESP window will let you know when the download is complete. Caution: Do not interrupt power or disconnect the host cable while download is in progress.
MS-880 Industrial Long Range Scanner User’s Manual
17-5
17–Utilities
2. Apply power to the scanner.
Page 248
Counters
Counters
17–Utilities
Counter commands can be a numeric value from 00000 to 65,535. After reaching the maximum numeric limit of 65,535, an error message will be displayed and the counter will automatically roll-over and start counting again at 00000. To obtain the cumulative total of counts after the roll-over has occurred, add 65,536 per each roll-over (the scanner does not keep track of the number of roll-overs) to the current count. Note: All counter values will be lost if power is recycled to the scanner or the scanner receives a reset or save command.
By ESP You can access Counters from the Utilities menu. Right-click the appropriate counter option and select Request to display count or Clear to set counter to zero.
By Serial Command Noread Counter Sending <N> displays the total number of noreads that have occurred since the last reset.
Noread Counter Reset Sending <O> sets Noread Counter to 00000.
Trigger Counter Sending <T> displays the total number of triggers since the last reset.
Trigger Counter Reset Sending <U> sets the trigger counter to 00000.
Good Read/Match Counter (or Good Read Counter) Sending <V> displays the total number of good reads matching the master label or, if Master Label is not enabled, the number of good reads since the last reset. This counter is always enabled, but will only work as a match count when Master Label is enabled. If Master Label is not enabled, this counter records the number of good reads. This count can be requested at any time.
17-6
MS-880 Industrial Long Range Scanner User’s Manual
Page 249
Chapter 17 Utilities Good Read/Match Counter Reset Sending <W> sets the Match Counter to 00000.
Mismatch Counter Sending <X> displays the number of decoded labels since the last reset that do not match the master label.
Mismatch Counter Reset Sending <Y> sets the Mismatch Counter to zero.
17–Utilities
MS-880 Industrial Long Range Scanner User’s Manual
17-7
Page 250
Part Number
Part Number You can send a request to the scanner for part numbers, checksums, boot code, and application and code.
17–Utilities
By ESP You can access Part Number from the Utilities menu. Right-click the appropriate option and select Request to see the associated part number or check sum number.
By Serial Command Upon sending <#> the scanner returns software part numbers for application code <#a/__________> and boot code <#b/_________>. Individual part numbers for Application Code and Boot Code are returned when their respective commands <#a> and <#b> are sent.
17-8
MS-880 Industrial Long Range Scanner User’s Manual