The text of a manual · part 24 of 32
MS-880 Industrial Long Range Scanner User's Manual, pages 231 to 240
Pages 231 to 240 of 312
The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-880
Page 231
Chapter 15 Diagnostics
Time Since Last Reset (This command is READ ONLY.) Definition: Usage: Serial Cmd:
Records the number of hours and minutes of operation since the last system reset. Useful as a troubleshooting tool that can help pinpoint the cause of a reset. Send <K407?> Returns <K407hours,minutes>
Read Only Ranges:
0 to 23 hours, 0 to 59 minutes.
15–Diagnostics
MS-880 Industrial Long Range Scanner User’s Manual
15-13
Page 232
15–Diagnostics
Time Since Last Reset
15-14
MS-880 Industrial Long Range Scanner User’s Manual
Page 233
Wiring Box Option
16 Chapter Contents Wiring Box Description ..........................................................................16-2 Installation Steps ...................................................................................16-3 Wiring Box Ports ....................................................................................16-5 Wiring Box PCB with Connectors ..........................................................16-8 Mounting Plate .......................................................................................16-9
This section has instructions for assembling, wiring and using the MS-880 scanner’s optional Wiring Box. When this option is selected, the Ms-880 scanner and wiring box option are shipped as an assembly.
MS-880 Industrial Long Range Scanner User’s Manual
16-1
16–Wiring Box
Chapter
Page 234
16–Wiring Box
Wiring Box Description
Wiring Box Description
Flex cable to MS-880 Scanner Portal hole, 3/4” pipe thread (4 places)
Bottom mounting plate of wiring box Figure 16-1 Wiring Box Note: Wiring Box PCB and Protocol Card (when used) reside inside the wiring box.
Portal Holes The wiring box has four external portal holes which are standard 3/4” pipe thread. Mounting of the box is with four through holes in flanges that extend out over the ends.
Terminal Strip Specifications Wire strip length: .24” (6 mm) Wiring range: 14 - 28 AWG Current: 13A maximum
16-2
MS-880 Industrial Long Range Scanner User’s Manual
Page 235
Chapter 16 Wiring Box Option
Note: For terminal details, see figure 16-2. 1. Connect power through portal holes (see “Connect the System” on page 1-3). 2. Temporarily apply power to the scanner and confirm that light next to input terminal is green and not red. 3. Disconnect power before making remainder of connections. 4. Connect host and trigger port wires through portal holes to appropriate connections. 5. Plug ribbon cable into scanner as shown below (apply pressure back and forth on connector to ensure that it seats inside the receptacle).
Ribbon Cable
Bottom plate of scanner attaches to top of wiring box Portal holes 3/4” pipe thread (4 places)
Wiring box
Bottom mounting plate of wiring box Figure 16-2 Scanner/Wiring Box Assembly 6. If using the network protocol card, connect card to underside of scanner (see the MS-880 Network Protocol User’s Manual (83-110015) for detailed information about the network protocol cards).
MS-880 Industrial Long Range Scanner User’s Manual
16-3
16–Wiring Box
Installation Steps
Page 236
16–Wiring Box
Installation Steps 7. Attach scanner to wiring box with 4 attached mounting screws in the bottom plate of the scanner, taking care that gasket is evenly seated.
Mounting screws 4 places
Figure 16-3 Attaching the Scanner 8. Mount wiring box (see “Wiring Box Ports” on page 16-5).
16-4
MS-880 Industrial Long Range Scanner User’s Manual
Page 237
Chapter 16 Wiring Box Option 16–Wiring Box
Wiring Box Ports (Refer to Figure 16-7 or actual PCB)
Relay Modules Note: For relay modules kits, use MS P/N 98-000013-XX or equivalent slim module which does not exceed 0.43” (11 mm) in width) 1.7" (1.1 cm) 0.43" (1.1 cm)
3 Relay module sockets
Locking screw
40-3100 08-0 1 REV. 2
K2 R E LA Y P AS S
1 3 5
J10
33
2 4 6
JP1
34
J13
1
J9
J7
J8
JP3
JP2
1
2
1
2
3
4
3
4
5
6
J15 5
6
R E LA Y P A SS
J17
2
MADE IN U.S.A.
J12
K3
43-31 0008 REV S/N :
K1
MICROSCA N
These can be used as an alternative to the 3 optoisolated outputs from the scanner itself. K1, K2, and K3 are pluggable module sockets for SM offthe-shelf AC/DC output/relay modules. Relay modules are installed as shown in Figure 16-4.
1
2
3
5
6
+5
GND
+
–
RX+
TX+ TX–
RX–
GND CHS
R EL A Y 2 O U T RE LA Y 3 O U T
Figure 16-4 Relay Module
Default jumper positions (using scanner's built-in relay)
1 3 5
New jumper position (using pluggable 1 3 5
2 4 6
2 4 6
JP1
JP1
JP2 JP3 40-31000 8-01 REV. 2
K1 K2 RE L A Y
1
PASS
3 5
J10
33
JP 1
J13
1 1 3 5
34
J8
J9
J7
K3
JP3
JP2 2 4 6
1
2
3
4
J15 5
6
2
R EL A Y P A SS
J17 MADE IN U.S.A.
J12
2 4 6
M ICROSCAN
When installing relay modules in K1, K2, and K3, corresponding jumpers (J1, J2, J3) need to be moved as shown in Figure 16-5. Move jumpers from 3-5 to 1-3 and 4-6 to 2-4 for each relay to be installed (K1, K2, K3).
43-310008REVS/N:
Jumpers
1
2
3
5
6
+5
GND
+
–
TX+ TX–
RX+
RX–
GND CHS
R ELA Y 2 O U T
R EL AY 3 O U T
Figure 16-5 Relay Jumpers
MS-880 Industrial Long Range Scanner User’s Manual
16-5
Page 238
Relay Terminals. Relay 2 terminal
40-310008-01 REV. 2
K1 K2 R EL AY PA SS
2 4 6
J10
33
JP1
J13
34
J7
J8
1
J9
K3
JP3
JP2
1
2
1
2
R EL AY
3
4
3
4
6
J15 5
P A SS
5
6
2
J17 M A D E I N U . S. A .
J12
1 3 5
Relay 3 terminal
M ICR OSCA N
Relay 1 terminal
4 3 -3 1 0 0 0 8 REVS/N:
16–Wiring Box
Wiring Box Ports
1
2
3
5
6
+5 GND
+
–
TX+ TX– RX+ RX– GND CHS
RE LAY 2 O U T R ELAY 3 O U T
Figure 16-6 Relay Module Relay terminals 1, 2, and 3 provide output for both internal optoisolated outputs and alternative relay modules that can be installed in modules K1, K2, and K3. Relay1 Output handles discrete outputs from the scanner that will switch up to 100 mA of opto-isolated current. See MS-880 Network Protocol Card User’s Manual (83-110015) for connections.
Field Bus Port (J10) Used with an optional protocol card to connect as a node from a network wired directly into this terminal strip.
+5 VDC Voltage out that can drive a hand held scanner. Maximum current is 5 watts.
Input 1 Used to wire a switch to reset latch mode or counters.
RS-422/485 Used for multidrop or 422 port.
Power 10-28 VDC Power input port (left side and right side for connectivity convenience).
16-6
MS-880 Industrial Long Range Scanner User’s Manual
Page 239
Chapter 16 Wiring Box Option
Main serial communication port. (See Table A-7, “Host 25-pin Connector,” on page A-8.)
Aux RS-232 Daisy chain and auxiliary connections. (See Table A-7, “Host 25-pin Connector,” on page A-8.)
New Master Pin Allows you to wire in a switch for New Master Pin. (See “Optoisolator Inputs” on page A-11.)
Trigger Port (NPN) To initiate the read cycle. (See “Optoisolator Inputs” on page A-11.)
Power LED GREEN means the polarity of the input connections is correct; RED means it is reversed. Caution: While the MS-880 scanner has reverse polarity protection built in to its circuitry, the wiring box does not protect external circuits that may already be wired in when power is applied.
MS-880 Industrial Long Range Scanner User’s Manual
16-7
16–Wiring Box
RS-232
Page 240
16-8 1 3 5
J1
P OW ER 10-28VDC P+ P -
RE LAY 1 O U T
J12
PA S S
RE LA Y
1
JP1
SH LD
2 4 6
K1
2
3
J13
4
34
J2
R TS R X
RS232
FIELDBUS
CTS
M2
M1
33
5
GND
6
TX
GN D
+
SHLD
RX
GND
J6
-
TX
INPUT1
J7
J10
AUX RS232
+5VDC
+5
J8
K2
TX -
-
J5
+
RX+
RX-
SHLD
RS422/485 NEWMASTER
TX+
J9
5
1 3
P-
2 4 6
G ND C H S
JP2
J3
TRIG P +
TRIGGER
2
1
40-310008-01 REV. 2
J15
1 3 5
JP3
M4
J17
J4
D1
MICROSCAN
PO WER LE D 10-28VD C
MADE IN U.S.A.
G REE N= OK R ED = RV S.PO L.
RELAY 3 OUT
P AS S
6
R ELA Y
2 4
POW ER 10-28VD C P+ P -
RELAY 2 OUT
M3
K3
43-310008REVS/N:
16–Wiring Box Wiring Box PCB with Connectors
Wiring Box PCB with Connectors
Polarity Indicator Green, if connected correctly, Red if incorrect.
Figure 16-7 Wiring Box PCB
MS-880 Industrial Long Range Scanner User’s Manual