Page 261
General Specifications Power LEDs (inside the wiring box) OFF = No power is present RED = power is present, but reversed GREEN = power is present and correct
Safety Certifications FCC, CDRH, CE, UL/cUL, TüV, BSMI
Product specifications are given for typical performance at 25°C (77°F) using grade A labels. Some performance characteristics may vary at high temperatures or other environmental extremes. © Microscan Systems, Inc., Specifications subject to change
Appendices
MS-880 Industrial Long Range Scanner User’s Manual
A-5
Page 262
Appendix B
Appendix B, Electrical Specifications Maximum Operating Power: 24 Watts Power Input: 10 to 28VDC, 200mV p-p max. ripple, 230 mA @ 24VDC (typical) Trigger, New Master, Input 1: 4.5 to 28 VDC (optoisolated)
Pin Assignments Note: See “Connect the System” on page 1-3 for power and host connections.
1
Appendices
Connectors on the back of the MS-880: 1 Power connector 2 Host 25-pin connector 3 Trigger connector
2
1
25 3
4
2
1
3
1
2
3
Figure A-3 Electrical Connectors
A-6
MS-880 Industrial Long Range Scanner User’s Manual
Page 263
Electrical Specifications Table A-4 Power Connector 1 2 3
Power grounda Chassis ground Power + 10 to 28 VDC
In a. Power ground: Used for power return only.
Caution: If using your own power supply, verify correct connection of power and ground lines. Incorrect connections or use of “Chassis ground,” “Power ground,” and “Signal ground” lines could cause equipment and/or software failure. Table A-5 Trigger Connector 1 2 3 4
Power +10 to 28 VDC NPN Power grounda N/C
Out a. Power ground: Used for power return only.
2 3 5 9
RxD232 TxD232 Signal grounda Boot Mode
Appendices
Table A-6 Host 9-pin Configuration Connector In Out a. Signal ground: Used for communication and signal line grounds only. Not to be used as power or chassis return.
MS-880 Industrial Long Range Scanner User’s Manual
A-7
Page 264
Appendix B Table A-7 Host 25-pin Connector1 Pin
Host RS232
Host & Aux Host RS232 RS422/485 Chassis grounda Host TxD Host RxD
1 2 3 4
RTS
5
CTS
6 7 8 9 10 11 12
Aux TxD
Out In Out
Aux RxD
In
Output 1 (+) Signal groundb Output 2 (+) Trigger (–) Trigger (+) N/C Input 1 (+)
Out Out In In In
13
RxD (+)
In
14
TxD (–)
Out
15
Noread/Output 3 (+)
16
Appendices
In/ Out
17 18
Power groundc Power +10 to 28 VDC
19 20 21 22 23 24 25
Out RxD (–)
TxD (+) Output 1 (–) Output 2 (–) Noread/Output 3 (–) Input 1 (–) New Master (–) New Master (+)
In In Out Out Out Out In In In a. Chassis ground: Used to connect chassis body to earth ground only. Not to be used as power or signal return. b. Signal ground: Used for communication and signal line grounds only. Not to be used as power or chassis return. c. Power ground: Used for power return only.
Caution: If using your own power supply, verify correct connection of power and ground lines. Incorrect connections or use of “Chassis ground,” “Power ground,” and “Signal ground” lines could cause equipment and/or software failure.
1. The host can also be accessed by the 9-pin configuration port connector on the side, by the IrDA port connector, or by connections inside the wiring box, if wiring box is used.
A-8
MS-880 Industrial Long Range Scanner User’s Manual
Page 265
Electrical Specifications
Optoisolator Outputs Optoisolator circuits can transfer pulses between the scanner and peripherals with no direct connection with the scanner’s internal circuitry. However, not every optoisolator configuration provides complete isolation. The following diagrams show both fully optoisolated and non-optoisolated circuits. They are only examples and do not represent all the possible wiring configurations. Generic Output Waveform Characteristics Iload =5mA Iload =50mA V Out-On
0.7V
Iload =100mA
0.9V
1.0V t On-Typ
30µS
20µS
30µS t Off-Typ
1000µS
150µS
75µS
Outputs (+)
Scanner Output
ILoad Outputs (–)
Output Circuit Examples Fully Optoisolated
Host
Isolated Scanner Power (+)
1 to 28 V Scanner
Outputs (+)
Output
Input Outputs (–) Power ground
Not Optoisolated, Scanner Grounded In this diagram, power is applied externally, but the scanner’s power ground is used to complete the circuit. This setup involves some risk to the optoisolator if excessive voltages are applied. Caution: The maximum current that can pass through the optoisolator is 100 mA.
Non-isolated Scanner
Host
Power (+) 1 to 28 V Scanner
Outputs (+)
Output
Input Outputs (–)
Power ground
MS-880 Industrial Long Range Scanner User’s Manual
A-9
Appendices
This circuit is fully optoisolated and the recommended configuration. It allows the user to apply 1 to 28 VDC to the circuit. Caution: The maximum current that can pass through the optoisolator is 100 mA.
Page 266
Appendix B Additional Isolated Output Circuit Examples Secondary Relay 1 to 28 V
Power +
Scanner Output
Outputs (+)
Outputs (–) Power ground Outputs (–)
Appendices
Power ground
A-10
V
PLC
Input
Outputs (+)
Output
PLC
Power +
RELAY
Isolated Scanner
Scanner
Isolated Scanner
MS-880 Industrial Long Range Scanner User’s Manual
PLC GND
Page 267
Electrical Specifications
Optoisolator Inputs All discrete inputs can be fully isolated pulses as PNP or NPN circuits. Inputs include trigger, new master, and other discrete inputs. Generic Waveform Characteristics Minimum
Maximum
VIN-HIGH/IIN-HIGH
4.5V/4mA
28V/33mA
VIN-LOW/IIN-LOW
0 V/0mA
2V/2mA
Pulse Widthmin
48 µS
Input (+) I load Input (–)
Note: Trigger pulses can be sent to the scanner either through the host 25-pin connector or a separate 4-pin trigger connector.
25-Pin Connector Input Examples Fully Optoisolated PNP Source +V
Isolated Scanner
V CC
+V Input (+)
Signal Input (+)
Input (–)
Input (–)
Signal
Not Optoisolated PNP Source
Non-isolated Scanner V CC
Power (+) Input (+)
+V
V CC Signal
NPN Source
Non-isolated Scanner Power (+)
+V
Input (+) Input (–)
Input (–)
Power ground
Power ground
MS-880 Industrial Long Range Scanner User’s Manual
Signal
A-11
Appendices
V CC
NPN Source
Isolated Scanner
Page 268
Appendix B 4-Pin Connector Trigger Input Example NPN Trigger Source Non-isolated
+V
+5 to 28 V V
Power (+) CC
Trigger (NPN) Signal
Appendices
Power (–)
A-12
MS-880 Industrial Long Range Scanner User’s Manual
Page 269
IrDA Configuration Port
Appendix C, IrDA Configuration Port
Serial Menu: Determines the flow of data between the infrared configuration port and a separate IrDA-equipped computer terminal. Serial Cmd: <K103,IR status,IR timeout,menu mode>
IrDA Status Definition: Usage: Serial Cmd: Default: Options:
Enables or disables the IrDA port. Can be used to disable all IrDA port functions when access by palmtops is not desired, or when the scanner's periodic infrared query pulses interfere with nearby optical sensors. <K103,IR status,IR timeout,menu mode> Disabled 0 = Disabled 1 = Enabled
MS-880 Industrial Long Range Scanner User’s Manual
A-13
Appendices
Provided the 9-pin configuration port is not being used, the IrDA infrared port is always active and can be used to communicate with an infrared-equipped IrDA Port remote terminal such as a laptop or a palmtop computer. It uses the standard IrCOMM 9-wire modem emulation. The Configuration Port communications parameters are fixed: parity = none, stop bits = 1, and data bits = 8, with the RTS/CTS channel not used. The IrDA port initially connects at a baud rate of 9600 b, then automatically increases the rate to 115K b, or to a smaller value as determined by your remote IrDA terminal. Figure A-4 Trigger Connector In order to communicate with the scanner's IrDA port, the remote infrared-equipped computer must contain a terminal-emulation software application and the application's serial port setting must redirect serial data to the computer's IrDA port. Note: If the IrDA port is being used to access the embedded menus and the infrared beam is interrupted for longer than the IR timeout time, then the system will exit from the embedded menus and a reset-without-save event will occur. Note: When the scanner's configuration port is connected to an RS-232 serial device, the IrDA channel will be disabled.
Page 270
Appendix C IR Timeout Definition:
Usage:
Serial Cmd: Default: Options:
If the infrared beam is interrupted for a period longer than the IR timeout, then the scanner's IrDA port will purge any pending data, reset its baud rate to 9600 baud, and begin transmitting a periodic query signal. If more than one IrDA-equipped computer terminal is to be used in rapid sequence with the same scanner, the scanner will not communicate with a second terminal until the infrared beam is blocked and the default 40-second timeout has expired. To quickly communicate with a second terminal, set the timeout to a smaller value. <K103, IR status,IR timeout,menu mode> 40 seconds 0 = 3 seconds 1 = 12 seconds 2 = 20 seconds 3 = 40 seconds
Embedded Menu Mode Appendices
Definition:
Usage:
Serial Cmd: Default: Options:
A-14
Enables or disables VT100 cursor control sequences for a particular scanner communication port. To change the status of a particular port, issue the command through that port. Note: The IrDA port communicates in VT100, the host, aux, and configuration ports use TTY. When a VT100-style computer terminal is connected to the host, aux, configuration, or IrDA port, set the port mode from TTY to VT100 in order to use the terminal's cursor control keys within the embedded menus. <K103, IR status,IR timeout,menu mode> VT100 0 = TTY 1 = VT100
MS-880 Industrial Long Range Scanner User’s Manual