The text of a manual · part 2 of 32
MS-880 Industrial Long Range Scanner User's Manual, pages 11 to 20
Pages 11 to 20 of 312
The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Microscan MS-880
Page 11
Keystrokes Serial commands, selections inside instructions, and menu defaults are highlighted in red bold. Cross-references are highlighted in blue. Web links and outside references are highlighted in blue bold italics. References to menu topics are highlighted in Bold Initial Caps. References to topic headings within this manual or other documents are enclosed in quotation marks.
Approvals This equipment is in compliance or approved by the following organizations: • CDRH (Center for Devices & Radiological Health) • UL (Underwriters Laboratories, Inc.) • cUL (UL mark of Canada) • TüV (Technischer überwachungs-Verein) • FCC (Federal Communication Commission) • CE Compliant • BSMI (Bureau of Standards, Metrology and Inspection)
MS-880 Industrial Long Range Scanner User’s Manual xi
Page 12
Safety Labels The following labels are located on the side and back of the MS-880 scanner:
AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS A PERTURE side
11-110013-01 CLASS II LASER PRODUCT
CAUTION LASER LIGHT DO NOT STARE INTO BEAM. 650 nm LASER DIODE 1.0 MILLIWATT MAX
LASERSTRA HLUNG, WENN ABDECKUNG
VORSICHT
GE ÖFFNET. NICHT IN DEN STRAHL BLICKEN
LASERSTRAHLUNG NICHT IN DEN STRAHL BLICKEN LASER KLASSE 2 94nJ @ 38uS
EN 60825-1: 1994 DIN VDE 0837 Teil 1: 1994-07
CA UTION-L AS ER L IG HT WH EN OP EN- DO NO T S TA RE INTO B EA M. P RODUCT CO NFORMS TO USA DHHS 21 CFR S UB CHAP TER "J" bottom xii
MS-880 Industrial Long Range Scanner User’s Manual
Page 13
Warning and Caution Summary This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help For connection to a UL listed direct plug-in power unit marked Class II and rated 10 to 28 VDC at 6 watts, or greater if using electrical accessories. European models must use a similarly rated Class I or Class II power supply that is certified to comply with standard for safety EN 60950.
WARNING Use of controls, adjustments, or performance of procedures other than those specified herein may result in hazardous laser light radiation exposure. WARNING There are no user serviceable parts in the scanner. Opening the scanner voids the Microscan Systems warranty and could expose the user to laser diode power of up to 7 mW. WARNING The laser beam can be harmful to eyesight. Avoid eye contact with the laser beam. Never point the beam at other people, or in a direction where people may be passing.
MS-880 Industrial Long Range Scanner User’s Manual xiii
Page 14
xiv
MS-880 Industrial Long Range Scanner User’s Manual
Page 15
Quick Start
1 Chapter Contents Step 1 Hardware Required ..........................................................................1-2 Step 2 Connect the System.........................................................................1-3 Step 3 Install ESP-MP .................................................................................1-6 Step 4 Select Scanner Model ......................................................................1-7 Step 5 Select the Communications Ports ....................................................1-8 Step 6 Connect with Auto Connect .............................................................1-9 Step 7 Retrieve Scanner Settings .............................................................1-10 Step 8 Compare Scanner Settings ............................................................1-11 Step 9 Position Scanner and Symbol ........................................................1-12 Step 10 Autocalibrate Scanner..................................................................1-13 Step 11 Test Range for Bar Code Label ...................................................1-14 Step 12 Make Changes to Configuration and Save ..................................1-15
This chapter is designed to get your scanner up and running quickly using Microscan’s ESP-MP™ so the user can get a sense of its capabilities and test bar code samples. Detailed setup information for installing the scanner into the actual application can be obtained in the subsequent chapters. In addition to ESP, you can send commands to your scanner by serial commands and through the scanner’s embedded menus.
MS-880 Industrial Long Range Scanner User’s Manual
1-1
1–Quick Start
Chapter
Page 16
1–Quick Start
Step 1, Hardware Required (Refer to figure 1-1.) To get started you will need: • An MS-880 standalone scanner (1) FIS-0880-0001, or an MS-880 scanner with a wiring box (2) FIS-0880-0002. • A host computer (3) with either a terminal communications program or Microscan’s ESP™ which runs under Windows™ operating system, Windows-95 or higher, including Windows NT™. • A null modem 9-pin configuration cable (4) P/N 61-000010-01. (Use cable P/N 61-300026-01 if your computer uses a 25-pin serial port connector.) • A power supply (5), P/N 97-100004-1005 (120V) or P/N 97-100004-06 (240V). Caution: If using your own power supply, be certain that it is wired correctly and supplies voltage within the +10 to 28 VDC limits. Incorrect wiring or voltage can cause software or equipment failures. Note: An optional object detector (6) is shown here (P/N 99-440001-10) with the standalone.
1 3 4
6
4
5 2 5
Figure 1-1 Hardware Configuration
1-2
MS-880 Industrial Long Range Scanner User’s Manual
Page 17
Chapter 1 Quick Start
Using the MS-880 Standalone 1. Attach your computer’s host cable to either the 9-pin shown in figure 1-2 or the 25-pin connector shown in figure 1-3. 2. The 9-pin port is used for setting up, testing, and defaulting the scanner. a. Attach power supply to the 3-pin power connector on the bottom of the scanner as shown in figure 1-3. IrDA port 2 Receive 3 Transmit 5 Signal ground
9-pin Host configuration connector
Figure 1-2 Side Connections
Chassis ground 2
3 Power +10 to 28 VDC (in)
Power ground 1
25-pin host connector 1 Power Ground 17
18 Power
Power connector
25 3
4
1 2 Trigger connector
Note: Power connector pins are best identified by their relationship to the notches on the outside edge of the connector.
Figure 1-3 Bottom Connections
MS-880 Industrial Long Range Scanner User’s Manual
1-3
1–Quick Start
Step 2, Connect the System
Page 18
1–Quick Start
Using the MS-880 with the Wiring Box 1. Make certain the wiring box power cord is not plugged in. 2. Connect the scanner to the computer. 3. Use the 9-pin configuration connector shown in figure 1-4 to connect with your computer. This port is useful for setting up, testing, and defaulting the scanner.
IrDA port
2 Receive
3 Transmit
5 Signal ground
9-pin Host Configuration Connector
Figure 1-4 MS-880 with Wiring Box 4. Connect power to the wiring box as shown in figure 1-5 on page 1-5.1 5. Apply power to the wiring box and confirm that the LED lamp next to right side power terminal is green and not red.2 6. Disconnect power.
1. Refer to Chapter 16, “Wiring Box Option” and Appendix B, “Electrical Specifications” for complete input/output details. 2. While the MS-880 scanner has reverse polarity protection built in to its circuitry, the wiring box does not protect external circuits that may already be wired in when power is applied.
1-4
MS-880 Industrial Long Range Scanner User’s Manual
Page 19
Chapter 1 Quick Start 1–Quick Start
Power Input +10 to 28 VDC
40-31000 8-0 1 K3 REV. 2
K1
K2 2 4 6
J10
33
1
M1
JP 1
34
J13
J8
J7
J9
JP3
JP2
1
2
3
4
5
6
2
R EL A Y
3
4
PA S S
5
6
J17
-
+
1
M3
J1 5
2
Shield MADE IN U.S.A .
J12
1 3 5
M ICRO S CAN
PA S S
4 3-3100 08 R EV S /N :
REL A Y
–
+
RELAY 1 OUT
-
1
2
3
4
5
6
+5
FIELDBUS
S HLD
RTS R X
GND
+
+5VDC
–
GND
TX
SHLD R X
TX+ TX–
INPUT1
AUX RS232
RS232
M2
C TS
POWER 1 0-28 VDC P+ P -
GND
RX+ RX–
NEWMASTER TX
GND CHS
+
R EL A Y 2 O U T R EL A Y 3 O U T
RS422/485
-
+
TRIGGER SHL D P- TRI G
P+
M4
POWER 10-28VDC P+ P -
D 1
POW ER 10-28VDC P+ P -
POWER LED 10-28VDC GREEN=OK RED=RVS.POL.
J 1
J2
Auxiliary power connector allows power cable to be conveniently installed from either end of the box.
J6
J5
J3
J4
DC–
DC+
Lamp is GREEN if polarity is correct Lamp is RED if polarity is reversed
Figure 1-5 Wiring Box Connections 7. Plug the ribbon cable (provided with wiring box) into the bottom of the scanner. See figure 16-2 on page 16-3. 8. Attach scanner to the wiring box with the 4 screws provided with the scanner. See figure 16-3 on page 16-4.
MS-880 Industrial Long Range Scanner User’s Manual
1-5
Page 20
1–Quick Start
Step 3, Install ESP-MP1 (ESP-MP is short for Easy Setup Program–Multi-Platform.) 1. Insert your Microscan CD into your computer’s CD drive. 2. Launch Setup.exe under ESP_Software\Multi_Platform and follow the prompts.2 If downloading from the web: a. Go to http://www.microscan.com/esp b. Enter your user name and password. c. Select ESP-MP and download to your computer hard drive. d. Extract ESP-MP WinZip files to a directory of your choice. 3. Note where your ESP.exe file is stored on your hard drive. At the end of the install process, you should see the following icon on your desktop:
4. Click the ESP-MP icon to start the program.
1. You can also access the scanner through its embedded menus. See Appendix H, “Embedded Menus.” 2. Contact your sales representative
1-6
MS-880 Industrial Long Range Scanner User’s Manual