Page 21
Chapter 1 Quick Start 1–Quick Start
Step 4, Select Scanner Model When you start the program, the following dialog box will appear:
Note: If you need to select another model later, you can find it under Model Select in the menu bar. 1. In the model dialog box, select your model. 2. Select the default name, MS-880-1 or type in a new name of your choice. 3. Click Yes when the following dialog on the right appears.
MS-880 Industrial Long Range Scanner User’s Manual
1-7
Page 22
1–Quick Start
Step 5, Select the Communications Ports When the following dialog appears:
1. Select 9-Pin Configuration Port or 25-Pin Host Port and click OK. 2. Select your communications port under COM Port.
COM1 is typically used for laptops. COM1 and COM2 are typically for desktop computers. 3. Click the Start button.
1-8
MS-880 Industrial Long Range Scanner User’s Manual
Page 23
Chapter 1 Quick Start
After clicking the Start button in the Connecting to... dialog, allow time for the auto connect routine to test all of the combinations. You will see a blue progress bar fill across the Connecting to... dialog. When connected, the CONNECTED message will appear in a green box in the status bar on the bottom right of the dialog.
Tip: If you do not see either the CONNECTED or DISCONNECTED message at the bottom of your dialog, try expanding the ESP window horizontally. Tip: If connection fails, enable a different Com port and try again.
MS-880 Industrial Long Range Scanner User’s Manual
1-9
1–Quick Start
Step 6, Connect with Auto Connect
Page 24
1–Quick Start
Step 7, Retrieve Scanner Settings Unless you have unchecked the default Upload After Autoconnect under Options, the communications values of the scanner will be loaded automatically and displayed under Scanner Values. If Upload After Autoconnect is not checked, the scanner values will not be loaded and ESP communications values will remain displayed under the heading, ESP Values. Tip: Before doing Retrieve Scanner Settings, you may want to preserve your current ESP settings to your computer as an ESP file by selecting Save or Save As in the File menu. At any time you can retrieve ALL scanner values by: 1. Right-clicking anywhere in the configuration window, and 2. Selecting Retrieve Scanner Settings. You can also retrieve settings by clicking on the Send/ Receive button.
This is useful if you want to: • Copy (upload) the scanner’s settings and save them as a computer file for later retrieval. • Ensure that whenever you save ESP settings to the scanner you are not saving any unwanted changes that you or someone else had made previously in ESP. By first doing Retrieve Scanner Settings, you eliminate that possibility.
1-10
MS-880 Industrial Long Range Scanner User’s Manual
Page 25
Chapter 1 Quick Start 1–Quick Start
Step 8, Compare Scanner Settings If you want to compare settings in the current scanner sideby-side with those in ESP without changing the ESP values: 1. Under the pull down Options menu check Show Comparison Column. 2. Right-click anywhere in the configuration window. 3. Select Retrieve as Comparison. After a short pause the scanner’s current settings will be displayed under the Comparison column. Compare those settings with the ESP values which are displayed under the ESP Values column. For example, if you change Background Color to Black, but haven’t yet saved this to the scanner, you will see the dissimilar program and scanner values highlighted in blue.
MS-880 Industrial Long Range Scanner User’s Manual
1-11
Page 26
1–Quick Start
Step 9, Position Scanner and Symbol Set up a symbol at the scanning distance you will be using in your application.
Centerline of scan window
( 90" 74"
Scan Range Starts Here
44"
35 "
9 2.2
(1.8
8m
2 (1.1
(.89 m) )
20 15 m)
m)
4 (.25 10"
10 mi
7 .5 l a b m il el mi l la l la be mi l la be be l l l m)
0"
Figure 1-6 Read Ranges In positioning the scanner and symbols being scanned, consider the following: • Avoid bright light or IR light from other sources, including other scanners. • Pitch or skew label or scanner a minimum of ±15° to avoid specular reflection, the return of direct, non-diffused light. Note: For additional tips on positioning the scanner and bar code labels, see “Position Scanner and Bar Code” on page A-28. Code 39 is the default code type enabled. If you are uncertain as to the symbology type, enable all codes, by clicking the Utilities menu and enabling Autodiscriminate under Code Types.
1-12
MS-880 Industrial Long Range Scanner User’s Manual
Page 27
1–Quick Start
Step 10, Autocalibrate Scanner Important: To receive bar code data through the 9-pin configuration port, you must enable the port with the following command: <K146,,1>. The MS-880 has a software routine that will automatically search and test a range of focus, gain and tracking settings and select those that achieve the best reads. 1. With a test label in place, start autocalibration by: a. ESP, clicking the Autocalibration button on the overhead toolbar and clicking the Auto Cal button to start autocalibration. b. serial command, sending <@CAL> from a terminal screen a. embedded menu, opening the autocalibration menu with <@> and pressing A. An “Autocalibration in Progress” message will be displayed on your monitor along with the pass number and information on the focus, gain, and tracking. 2. Allow some time for the scanner to cycle through the focus, gain, and tracking settings. Do not move or disturb scanner or label while Autocalibration is in progress. (It might take 2 to 3 minutes to complete.) 3. When completed, the settings that provided the highest read rate will be selected. You will see one of the following messages: “Autocalibration Passed”, “Autocalibration Failed,” or “Original Settings Were Optimal.” If autocalibration passes, the scanner sends data to your computer and emits a beep (if beeper is enabled) for each good read and you will continue to see the read rate percentage and label data in the window below the scanner image. Note: If you wish to silence the beeper, interrupt reading by removing or blocking the test label, or send a <K702,0> command to disable the beeper.
If calibration fails, try the following: • Check the read range for your particular label density. • Examine label quality and try a different sample label. • Slightly skew or tilt the label or scanner to minimize specular reflection. • Ensure that the correct code type is enabled for the label you are scanning. Note: See Chapter 6, “Autocalibration” for more details on calibration.
1-13
MS-880 Industrial Long Range Scanner User’s Manual
Page 28
1–Quick Start
Step 11, Test Range for Bar Code Label 1. Position a label in front of an operational scanner.1 20 mil Code 39 Test Symbol
You can also find test symbols on the back of the Microscan Marketing CD jacket. The 20 mil refers to the width of the narrowest bar (e.g., 7.5 mil = .0075" or .1905 mm).
2. Click the Utilities button. 3. Right-click Read Rate and select Start. 4. Observe rate in terminal window on the right of the Utilities screen. 5. Move your bar code label towards the scanner and away from the scanner until the decode rates drop off in each direction as shown in figure 1-7. This will give you a sense of the depth of field (inner and outer ranges) for your symbol’s density and range. 6. To end test, right-click Read Rate and select the Stop button. Note: If the scanner is in the default Continuous Read mode and not in read rate or autocalibration, it will read and beep repeatedly as long as a readable label remains in the read range and the read cycle configuration has not changed. De pth field of
Figure 1-7 Depth of Field
1. If using an I 2/5 label, verify that the number of characters in the label being scanned matches the code length enabled for the I 2/5 code type (default is 10 and 6). See “Interleaved 2 of 5” on page 5-14.
1-14
MS-880 Industrial Long Range Scanner User’s Manual
Page 29
1–Quick Start
Step 12, Make Changes to Configuration and Save To make changes to a configuration setting: 1. Double-click the setting (for example, End of Read Cycle).
2. Place your pointer in the selection box, scroll down to the setting of your choice and left-click on the setting. 3. Left-click again anywhere in the configuration window to complete the selection. 4. Right-click in the configuration window and select Save to Scanner to implement the command in the scanner. You have 3 choices: a. Send, No Save. This initializes all changes in active memory. These changes will be lost if power to the scanner is cycled. b. Send and Save. This will cause the scanner to beep, indicating that the change has been implemented and that all changes have been saved to the scanner’s NOVRAM for power-on, except factory settings.1 c. Advanced/Send and Save, Including Factory. Same as above, except that changes to factory settings will also be saved for power-on. Note: For Multidrop setup, see “Multidrop Communications” on page A-38.
1. Consult your model specific user’s manual for a list of factory settings.
1-15
MS-880 Industrial Long Range Scanner User’s Manual