Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 32

MS-880 Industrial Long Range Scanner User's Manual, pages 1 to 10

Pages 1 to 10 of 312

The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Microscan MS-880

Page 1 read from a scan by OCR; it may hold reading errors

MICROSCAN.

MS-880

Industrial

Long Range Scanner User's Manual

P/N 83-000880 Rev G

Page 2

Copyright © 2002 by Microscan Systems, Inc., 1201 S.W. 7th Street, Renton, Washington, U.S.A. 98055 (425) 226-5700 FAX: (425) 226-8682 ISO 9001/Certification No. 00-1047 All rights reserved. The information contained herein is proprietary and is provided solely for the purpose of allowing customers to operate and/or service Microscan manufactured equipment and is not to be released, reproduced, or used for any other purpose without written permission of Microscan. Throughout this manual, trademarked names might be used. Rather than put a trademark (™) symbol in every occurrence of a trademarked name, we state herein that we are using the names only in an editorial fashion, and to the benefit of the trademark owner, with no intention of infringement. Disclaimer The information and specifications described in this manual are subject to change without notice. Latest Manual Version For the latest version of this manual, see the Download page on our web site at www.microscan.com. For technical support email helpdesk@microscan.com.

ii

MS-880 Industrial Long Range Scanner User’s Manual

Page 3

Microscan Limited Warranty Statement and Exclusions What is Covered? Microscan Systems Inc. warrants to the original purchaser that products manufactured by it will be free from defects in material and workmanship under normal use and service for a period of one year from the date of shipment. This warranty is specifically limited to, at Microscan’s sole option, repair or replacement with a functionally equivalent unit and return without charge for service or return freight. What is Excluded? This limited warranty specifically excludes the following: (1) Any products or parts that have been subject to misuse, neglect, accident, unauthorized repair, improper installation, or abnormal conditions or operations; (2) Any products or parts that have been transferred by the original purchaser; (3) Customer mis-adjustment of settings contrary to the procedure described in the Microscan Systems Inc. owners manual; (4) Upgrading software versions at customer request unless required to meet specifications in effect at the time of purchase; (5) Units returned and found to have no failure will be excluded; (6) Claims for damage in transit are to be directed to the freight carrier upon receipt. Any use of the product is at purchaser’s own risk. This limited warranty is the only warranty provided by Microscan Systems Inc. regarding the product. Except for the limited warranty above, the product is provided “as is.” To the maximum extent permitted by law, this express warranty excludes all other warranties, express or implied, including but not limited to, implied warranties of merchantability and fitness for a particular purpose. Microscan Systems Inc. Does not warrant that the functions contained in the product will meet any requirements or needs purchaser may have, or that the product will operate error free, or in an uninterrupted fashion, or that any defects or errors in the product will be corrected, or that the product is compatible with any particular machinery. Limitation of Liability. In no event shall Microscan Systems Inc. be liable to you or any third party for any special, incidental, or consequential damages (including, without limitation, indirect, special, punitive, or exemplary damages for loss of business, loss of profits, business interruption, or loss of business information), whether in contract, tort, or otherwise, even if Microscan Systems Inc. has been advised of the possibility of such damages. Microscan Systems Inc.’s aggregate liability with respect to its obligations under this warranty or otherwise with respect to the product and documentation or otherwise shall not exceed the amount paid by you for the product and documentation. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on an implied warranty, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which may vary from state to state.

MS-880 Industrial Long Range Scanner User’s Manual iii

Page 4

Table of Contents Chapter 1

Quick Start

Step 1 Hardware Required...................................................................... 1-2 Step 2 Connect the System .................................................................... 1-3 Step 3 Install ESP-MP............................................................................. 1-6 Step 4 Select Scanner Model.................................................................. 1-7 Step 5 Select the Communications Ports................................................ 1-8 Step 6 Connect with Auto Connect ......................................................... 1-9 Step 7 Retrieve Scanner Settings ......................................................... 1-10 Step 8 Compare Scanner Settings........................................................ 1-11 Step 9 Position Scanner and Symbol.................................................... 1-12 Step 10 Autocalibrate Scanner ............................................................. 1-13 Step 11 Test Range for Bar Code Label ............................................... 1-14 Step 12 Make Changes to Configuration and Save .............................. 1-15

Chapter 2

Communications

Communications Options ........................................................................ 2-2 Host Port Parameters.............................................................................. 2-5 RS422 Status .......................................................................................... 2-7 Auxiliary Port ........................................................................................... 2-8 Daisy Chain Autoconfigure.................................................................... 2-16 Daisy Chain Remote Scanner ID .......................................................... 2-17 IrDA Port ............................................................................................... 2-18 Menu Mode ........................................................................................... 2-19

Chapter 3

Protocol

Protocol ................................................................................................... 3-4 LRC ......................................................................................................... 3-9 Response Timeout ................................................................................ 3-10 Intercharacter Delay.............................................................................. 3-11 Output Data Format .............................................................................. 3-12 Auxiliary/Configuration System Data..................................................... 3-14 Network Client....................................................................................... 3-15

Chapter 4

Read Cycle/Trigger

Trigger Mode........................................................................................... 4-4 Serial Trigger......................................................................................... 4-10 External Trigger State ........................................................................... 4-12 End of Read Cycle ................................................................................ 4-13 Multilabel ............................................................................................... 4-16

Chapter 5

Codes

Narrow Margins....................................................................................... 5-5 iv

MS-880 Industrial Long Range Scanner User’s Manual

Page 5

Symbology ID .......................................................................................... 5-6 Background Color.................................................................................... 5-7 Code 39 ................................................................................................... 5-8 Codabar................................................................................................. 5-11 Interleaved 2 of 5................................................................................... 5-14 UPC/EAN............................................................................................... 5-17 PDF417 ................................................................................................. 5-20 Code 128 ............................................................................................... 5-22 UCC/EAN-128 ....................................................................................... 5-23 Code 93 ................................................................................................. 5-26 Pharma Code ........................................................................................ 5-27 Autodiscriminate .................................................................................... 5-29

Chapter 6

Autocalibration

Overview of Autocalibration..................................................................... 6-2 Autocalibration by ESP............................................................................ 6-4 Autocalibration by Serial Command ........................................................ 6-7 Autocalibration by Embedded Menu........................................................ 6-8

Chapter 7

Calibration Database

Overview of Calibration Database ........................................................... 7-2 Calibration Database by ESP .................................................................. 7-3 Calibration Database by Serial Command .............................................. 7-4 Calibration Database by Embedded Menu.............................................. 7-6

Chapter 8

Optoelectrics

Overview of Optoelectrics........................................................................ 8-4 Optoelectric Database Modes ................................................................. 8-5

Chapter 9

Raster/LaserControl

Raster Setup............................................................................................ 9-3 Laser Setup ............................................................................................. 9-6 Raster/Laser by Embedded Menu........................................................... 9-9

Chapter 10

Scanner Setup

Scan Speed ........................................................................................... 10-4 Focus..................................................................................................... 10-5 Gain Adjustment .................................................................................... 10-6 Tracking................................................................................................. 10-6 Transition Counter ................................................................................. 10-7 Maximum Element ................................................................................. 10-8

Chapter 11

Matchcode

Overview of Matchcode ......................................................................... 11-4 Matchcode Type .................................................................................... 11-5 MS-880 Industrial Long Range Scanner User’s Manual v

Page 6

Master Label Database ....................................................................... 11-11 New Master Pin................................................................................... 11-16

Chapter 12

Outputs

Noread Message................................................................................... 12-4 Bar Code Output ................................................................................... 12-5 Serial Verification .................................................................................. 12-8 Beeper Status ..................................................................................... 12-10 Quality Output ..................................................................................... 12-11

Chapter 13

Output Format and Filtering

Overview of Output Format/Filtering ..................................................... 13-4 Extraction Mode .................................................................................... 13-5 Insertion Mode ...................................................................................... 13-7 Advanced Output Format by ESP ......................................................... 13-9 Multilabel Output Format Assignment ................................................. 13-10 Ordered Output/Filtering ..................................................................... 13-11 Master Database in ESP..................................................................... 13-16

Chapter 14

Discrete I/0

Input 1 ................................................................................................... 14-4 Output 1 ................................................................................................ 14-5 Output 2 .............................................................................................. 14-10 Output 3 .............................................................................................. 14-10 Diagnostic Outputs.............................................................................. 14-11

Chapter 15

Diagnostics

Warning Messages ............................................................................... 15-4 High Temperature Threshold ................................................................ 15-8 Low Temperature Threshold ................................................................. 15-9 Lifetime Hours ..................................................................................... 15-10 Present Ambient Temperature (deg. C) .............................................. 15-11 Counts................................................................................................. 15-12 Time Since Last Reset ........................................................................ 15-13

Chapter 16

Wiring Box Option

Wiring Box Description.......................................................................... 16-2 Installation Steps................................................................................... 16-3 Wiring Box Ports ................................................................................... 16-5 Wiring Box PCB with Connectors.......................................................... 16-8 Mounting Plate ...................................................................................... 16-9

Chapter 17

Utilities

File Transfer .......................................................................................... 17-5 Counters................................................................................................ 17-6 vi

MS-880 Industrial Long Range Scanner User’s Manual

Page 7

Part Number .......................................................................................... 17-8 Checksum.............................................................................................. 17-9 Read Rate ........................................................................................... 17-10 Device Control ..................................................................................... 17-12 Code Type ........................................................................................... 17-13 Defaulting/Saving/Initializing................................................................ 17-13

Appendices Appendix A General Specifications .........................................................A-2 Appendix B Electrical Specifications .......................................................A-6 Appendix C IrDA Configuration Port......................................................A-13 Appendix D IrDA/Ir Comm for Palm Pilot...............................................A-15 Appendix E Serial Configuration Commands ........................................A-16 Appendix F Serial Command Format ....................................................A-19 Appendix G ASCII Table .......................................................................A-21 Appendix H Embedded Menus..............................................................A-23 Appendix I Defaulting/Saving/Initializing................................................A-24 Appendix J Position Scanner and Bar Code .........................................A-28 Appendix K Position Object Detector ....................................................A-29 Appendix L Test Decode Rate...............................................................A-30 Appendix M Formulas for Number of Decodes ....................................... A-31 Appendix N Operational Tips.................................................................A-35 Appendix O Interface Standards ...........................................................A-36 Appendix P Multidrop Communications.................................................A-38 Appendix Q Glossary of Terms .............................................................A-43

MS-880 Industrial Long Range Scanner User’s Manual vii

Page 8

List of FiguresFigure 1-1 Hardware Configuration 1-2 Figure 1-2 Side Connections ..................................................................... 1-3 Figure 1-3 Bottom Connections ................................................................. 1-3 Figure 1-4 MS-880 with Wiring Box ........................................................... 1-4 Figure 1-5 Wiring Box Connections ........................................................... 1-5 Figure 1-6 Read Ranges ......................................................................... 1-12 Figure 1-7 Depth of Field ......................................................................... 1-14 Figure 4-1 Trigger Level ............................................................................ 4-6 Figure 4-2 Trigger Edge ............................................................................. 4-7 Figure 6-1 Typical Autocalibration Graph .................................................. 6-2 Figure 6-2 Autocalibration Setup ............................................................... 6-3 Figure 6-3 Autocalibration In Process ........................................................ 6-4 Figure 6-4 Autocalibration Passed ............................................................. 6-4 Figure 6-5 Embedded Autocalibration Setup Menu ................................... 6-8 Figure 6-6 Embedded Calibration Results Menu ..................................... 6-11 Figure 6-7 Advanced Autocalibration Menu ............................................. 6-12 Figure 7-1 Database Menu ........................................................................ 7-3 Figure 8-1 Control Trigger Inputs ............................................................... 8-8 Figure 8-2 ESP Control Trigger Setup ....................................................... 8-8 Figure 9-1 ESP Laser Framing Control ..................................................... 9-7 Figure 9-2 Laser Framing Pattern .............................................................. 9-7 Figure 9-3 Embedded Calibration Results Menu ....................................... 9-9 Figure 12-1 Read Cycle ........................................................................... 12-7 Figure 13-1 Output Format Extraction ..................................................... 13-5 Figure 13-2 Output Format Insertion ....................................................... 13-7 Figure 13-3 Advanced Formatting Screen ............................................... 13-9 Figure 13-4 Multilabel Output Format Status ......................................... 13-10 Figure 16-1 Wiring Box ............................................................................ 16-2 Figure 16-2 Scanner/Wiring Box Assembly ............................................. 16-3 Figure 16-3 Attaching the Scanner .......................................................... 16-4 Figure 16-4 Relay Module ....................................................................... 16-5 Figure 16-5 Relay Jumpers ..................................................................... 16-5 Figure 16-6 Relay Module ....................................................................... 16-6 Figure 16-7 Wiring Box PCB .................................................................... 16-8 Figure 16-8 Wiring Box Bottom Plate ...................................................... 16-9 Figure A-1 MS-880 Scanner Dimensions .................................................. A-2 Figure A-2 Mounting Dimensions .............................................................. A-4 Figure A-3 Electrical Connectors ............................................................... A-6 Figure A-4 Trigger Connector .................................................................. A-13 Figure A-5 Scanner/Label Position .......................................................... A-28 viii

MS-880 Industrial Long Range Scanner User’s Manual

Page 9

Figure A-6 Object Detector ......................................................................A-29 Figure A-7 Ladder ....................................................................................A-31 Figure A-8 Raster Picket Fence ...............................................................A-32 Figure A-9 Picket Fence ...........................................................................A-33 Figure A-10 Angled Picket Fence ............................................................A-33 Figure A-11 Polling Sequence .................................................................A-40 Figure A-12 Polling Sequence .................................................................A-41

List of Tables Table 5-1 Symbology Identifier Option Values ........................................... 5-6 Table 9-1 Maximum Sweep Rates at Selected Sweep Arcs ...................... 9-5 Table 11-1 Maximum Characters for Master Label Database ............... 11-13 Table 17-1 Summary of Utility Serial Commands .................................... 17-3 Table A-1 MS-880 FIS Options ..................................................................A-3 Table A-2 MS-880 Read Ranges ...............................................................A-3 Table A-3 MS-880 Status Lights (on the side of the MS-880) ....................A-4 Table A-4 Power Connector .......................................................................A-7 Table A-5 Trigger Connector ......................................................................A-7 Table A-6 Host 9-pin Configuration Connector ..........................................A-7 Table A-7 Host 25-pin Connector ...............................................................A-8 Table A-8 Serial Configuration Commands in Numeric Order .................A-16 Table A-9 ASCII Table with Control Characters .......................................A-21 Table A-10 Communication Protocol Commands ....................................A-22 Table A-11 Multidrop Addresses ..............................................................A-42

About the MS-880 Scanner The MS-880 scanner is designed for versatile, robust operation in an industrial automation environment. It offers wireless programming, autofocus, Windows-based software, linear and 2-D code reading, several connectivity paths, multiple protocol and communications options, and a variety of advanced input/output features. Its application code resides in an onboard flash memory chip that can be easily updated by downloads.1 A user interface program, the ESP-MP (Easy Setup Program–Multi-platform), can be downloaded from our web site (www.microscan.com) and runs on Microsoft Windows 95™, Windows 98™, Windows NT™ and Windows 2000™ operating systems. Alternately, configuration commands can be sent from an embedded, menudriven terminal program, or directly by host serial command strings. The scanner is offered as a standalone or in combination with a wiring box. Four optional network plug-in protocol cards are also available when using the wiring box option. 1. See your Microscan sales representative to access the latest application codes. MS-880 Industrial Long Range Scanner User’s Manual ix

Page 10

About This Manual This manual provides complete information on setting up, installing, and configuring the MS-880 scanner. The chapters are presented in the order in which a scanner might be setup and made ready for industrial operation. Host serial commands are presented side-by-side with ESP and embedded menus. Chapter 1, “Quick Start” provides overall step-by-step instructions for getting your scanner operational with specific “go to” references to other chapters and appendices. Chapter 6, “Autocalibration” explains in detail the autocalibration procedure and the interpretation of the results. Chapter 7, “Calibration Database” tells how to setup a database of the optical settings you gathered in autocalibration. Chapter 8, “Optoelectrics” tells how to setup input/output connections for control of calibration database settings and includes gain, tracking, and AGC settings. Chapter 9, “Raster/Laser Control” explains raster and laser setup settings. Chapter 11, “Matchcode”, Chapter 12, “Outputs”, and Chapter 13, “Output Format and Filtering” provide instructions for setting up matching labels, data output, and data formatting for special operations. Chapter 14, “Discrete I/0” lists input/output functions controlled by discrete electrical levels, including diagnostic warning outputs setup in Chapter 15, “Diagnostics.” Chapter 16, “Wiring Box Option” describes the wiring box, if used, and it’s installation and port connections. Chapter 17, “Utilities” describes ESP-MP utility commands and their related serial commands for read rate tests, defaulting, etc. The appendices include specifications, reference tables of serial commands, ASCII characters, multidrop setup and addresses, as well as other useful information relating to bar coding and electrical and mechanical setups for the scanner.

Host Communications There are three ways the scanner communicates with a host: 1. Microscan’s Windows™ based ESP-MP™ (Easy Setup Program - Multi-Platform), the preferred method which offers point-and-click ease of use and visual responses to user adjustments. 2. Serial commands such as <K100,r1> can be sent from a terminal program. They can also be sent from the Terminal or Utility window within ESP-MP. 3. Embedded onboard menus are accessed from a terminal window with a <D> command. These menus lack some of the functionality of the ESP-MP, but may be more responsive in older, slower computers.

x

MS-880 Industrial Long Range Scanner User’s Manual