Page 171

Chapter 11 Matchcode

Sequence On Mismatch Note: Matchcode must be set to Sequential for this command to function. When set to Enabled, the master label sequences on every decode, match or mismatch. When set to Disabled, the master label will not sequence whenever consecutive mismatches occur.

Usage:

Enable this parameter if every trigger event should have a decode and more than one consecutive mismatch may occur. Disable this parameter if every trigger event should have a decode but no more than one consecutive mismatch may occur.

Serial Cmd:

<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on noread,sequence on mismatch>

Default:

Disabled

Options:

0 = Disabled,

1 = Enabled

The scanner will sequence the master to one more/less than the decoded symbol. As an example of Sequence On Mismatch Enabled, consider the following decodes: Master label

Decoded label

001 002 003 004 005 006 007

001 002 abc 004 def ghi 007

Master label after decode 002 003 004 (sequenced on mismatch) 005 006 (sequenced on mismatch) 007 (sequenced on mismatch) 008

As an example of Sequence On Mismatch Disabled, consider the following decodes: Master label

Decoded label

001 002 003 004 005 006 006

001 002 abc 004 def ghi 006

Master label after decode 002 003 004 (sequenced because of previous match) 005 006 (sequenced because of previous match) 006 (not sequenced because of previous mismatch) 007

MS-880 Industrial Long Range Scanner User’s Manual

11-9

11–Matchcode

Definition:

Page 172

Matchcode Type

11–Matchcode

Sequence Step Definition:

Sequencing in Matchcode operations can occur in steps from 1 to 32,768. Sequencing performs like a mechanical counter by displaying positive integers and a specific number of digits after roll-overs. For example, 000 – 3 = 997 (not –3) and 999 + 3 = 002 (not 1002).

Usage:

Useful in applications in which it is desirable to count by intervals other than 1.

Serial Cmd:

<K228,sequence step>

Default:

1

Options:

1 to 32,768

Note: See <K223> commands (“Matchcode Type” on page 11-5) for more information. As an example of Sequence Step, if Sequence Step is set to 3 and Sequential Matching is set to Increment. Master label 003 003 003 006 006 006

11-10

Decoded label 001 002 003 004 005 006

Master label after decode 003 003 006 006 006 009

MS-880 Industrial Long Range Scanner User’s Manual

Page 173

Chapter 11 Matchcode

Master Label Database Important: Master Label Database is used only for comparing entire bar codes, when Sequential and Wild Card are NOT enabled, and Start Position is equal to 0.

Master Label Database Overview Allows you to define up to 10 master labels as the master label database, which can be entered by keyboard, scanned-in, displayed, or deleted by serial or ESP commands.

Usage:

Useful where more than one master label is required, as in a Multilabel setup, for matching and other matchcode operations.

Master Label Database Size Definition:

Master Label Data Base Size allows you to select 1 to 10 master labels for the master label database.

ESP:

Click the Matchcode button to access the master label:

First set the number of master labels you want to include by doubleclicking Database Size and entering the number.

Double-click here and set the master label database size.

Serial Cmd:

< master label data base size> Note: You must follow this command with a save command <A> or <Z>.

Default:

1

Options:

1 to 10

MS-880 Industrial Long Range Scanner User’s Manual

11-11

11–Matchcode

Definition:

Page 174

Master Label Database

Enter Master Label Data Allows you to enter master label data for a specific master label index number (1 to 10), provided the index number is not larger than the number of labels enabled by the Master Label Database Size (see page 11-11). For example, if Master Label Database Size is set to 2, you will not be able to enter data for labels 3 through 10.

ESP:

Click the Output Format button on the tool bar and click the Master Database tab.

11–Matchcode

Definition:

Double-click here to open the label data window.

Enter data here for label # 2.

Serial Cmd:

<K231,master label number,master label data>

Default:

1, blank

Options:

1 to 10, data (any combination of ASCII text up to the maximum indicated in “Maximum Characters for Master Label Database” on page 11-13). For example, to enter data for master label 9, after making certain that master label database size is enabled for 9 or more labels (see “Master Label Database Size” on page 11-11), send <KK231,9,data>.

11-12

MS-880 Industrial Long Range Scanner User’s Manual

Page 175

Chapter 11 Matchcode Caution: Since the total number of characters available for the master label data base is2710 changes to the Master Label Data Base Size will re-allocate the number of characters available for each master label and could cause existing master labels to be deleted (except master label #1 unless it also exceeds the size limitation). The table below specifies the maximum number of characters available to each label according to the number of master labels defined, from 1 through 10. See “Master Label Database Size” on page 11-11. Table 11-1 Maximum Characters for Master Label Database Maximum Characters 2710 1355 903 677 542

Master Label Number #6 #7 #8 #9 #10

11–Matchcode

Master Label Number #1 #2 #3 #4 #5

Maximum Characters 451 387 338 301 271

Request Master Label Data Serial Cmd:

<K231,master label number?> This will display data in the master label number you indicated. For example, to request master label #5, enter <K231,?>. The scanner transmits master label #5 data in brackets in the following format: <K231,5/.....>. If no master label data available, the output will be: <K231,5,>.

ESP:

Double-clicking the Master Database tab, as shown under “Enter Master Label Data” on page 11-12, will display current master label data for all master labels.

Request All Master Label Data Serial Cmd:

<K231,?> This command will return master label data for all labels enabled (up to 10).

ESP:

Double-clicking the Master Database tab, as shown under “Enter Master Label Data” on page 11-12, will display current master label data for all master labels.

MS-880 Industrial Long Range Scanner User’s Manual

11-13

Page 176

Master Label Database

11–Matchcode

Delete Master Label Data Definition:

You can directly delete the master label data by serial command or ESP.

ESP:

You can also delete master label data for any master label by erasing the data in the Master Database popup window (under Output Format) and clicking OK, as shown here.

Serial Cmd:

<K231,master label number,> To delete a master label, enter the database number and a comma, but leave the data field empty. For example, to delete master label #5, send the following <K231,5,>. The command is entered with a blank master label data field which tells the scanner to delete the selected master label from the database.

Default:

(no data)

Options:

Any combination of ASCII text up to the maximum indicated in “Maximum Characters for Master Label Database” on page 11-13.

11-14

MS-880 Industrial Long Range Scanner User’s Manual

Page 177

Chapter 11 Matchcode

Store Next Label Scanned as Master Label1 Definition:

After you’ve set the size in the database (“Master Label Database Size” on page 11-11), you can order the scanner to scan-in the next label as the master label for any given master label number.

ESP:

In the Master Database tab, under the Output Format menu 1. Select the master label index number in which you want to store the label data.

11–Matchcode

2. Click on the Scan Label into Selected Index. Serial Cmd:

<G master label number> To store the next label scanned as master label #1, send: <G> or <G1>. To store next label scanned as the master label for any other master label database number, send: <G master label number [1-10]>. For example, <G5> will cause the next label scanned to be entered as master label #5.

Default:

(no data)

1. While not strictly a configuration command, <G> is included here because it is so closely related to other master label commands. MS-880 Industrial Long Range Scanner User’s Manual

11-15

Page 178

New Master Pin

11–Matchcode

New Master Pin Definition:

After New Master Pin is enabled, a pulse can be received on the new master pin which will cause the scanner to record the next decoded bar code label(s) as the new master label(s). It is important to note that the enabling New Master Pin does not in itself cause a master label to be recorded. The master pin must then be activated momentarily (for a minimum of 10 ms) before a master label can be scanned into memory. (See Table A-7, “Host 25-pin Connector,” on page A-8and Figure 16-7, Wiring Box PCB, on page 16- 8.)

Usage:

Some applications require the line worker to change the master label. This can be done by installing a switch at the location of the scanner. It is very common to have a keyed switch so that accidental switching does not occur.

ESP:

In the Matchcode menu, select New Master Pin, double-click on Disabled and select Enabled.

Serial Cmd:

<K225,status>

Default:

Disabled

Options:

0 = Disabled

1 = Enabled

After New Master Pin has been enabled and the pin activated, decodes will be saved in the master database beginning with master label #1. If the scanner is configured for a multilabel read cycle (Number of Labels is greater than 1), the remaining decodes will be saved in each consecutive master label location. For example, if Number of Labels is set to 3 and New Master Pin is then activated, at the end of the next read cycle, the decoded bar code labels will be saved as master labels 1, 2, and 3.

11-16

MS-880 Industrial Long Range Scanner User’s Manual

Page 179

Chapter

Outputs

12 Chapter Contents

This section explains the commands for controlling data and beeper outputs. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.

MS-880 Industrial Long Range Scanner User’s Manual

12-1

12–Outputs

Output Data by Embedded Menu ..............................................................12-4 Bar Code Output........................................................................................12-6 Noread Message .......................................................................................12-9 Beeper Status..........................................................................................12-10 Quality Output..........................................................................................12-11 Serial Verification.....................................................................................12-12

Page 180

Outputs by Serial Command old cmds new cmds

Serial Verification

KS

K701,

Beeper Quality Output Bar Code Output Output During Diagnostic Warning Messages Noread Message

Ku KJ Kl

K702, K704, K705,

Command Title

K713, Kk

K714,

Format <K701,serial command echo status,serial command beep status,control/hex output> <K702,status> <K704,quality output separator,reads/trigger status> <K705,status,when to output> <K713,channel,status1,status2,status3,status4, status5,status6,status7,status8,status9> <K714,status,message>

Outputs by Embedded Menu

12–Outputs

For information on accessing the embedded menus, see “Embedded Menus” on page A-23. From the Main menu, scroll down through the options and select the following screen:

12-2

MS-880 Industrial Long Range Scanner User’s Manual