Page 181
Chapter 12 Outputs
Output Data by ESP Menu
Click this button to bring up the Outputs menu.
Note: For Raster Setup and Laser Setup, see Chapter 9, “Raster/Laser Control.”
MS-880 Industrial Long Range Scanner User’s Manual
12-3
12–Outputs
To change a setting, double-click the setting and use your curser to scroll through the options.
Page 182
Noread Message
Noread Message Definition: Usage:
When enabled, and if no bar code label has been decoded before timeout or the end of the read cycle, the noread message will be transmitted to the host. Used in applications where the host needs serial verification that a label has not been read and especially useful in new print verification.
Noread Status Serial Cmd: Default: Options:
<K714,status,message> Enabled 0 = Disabled 1 = Enabled
Noread Message
12–Outputs
Definition: Serial Cmd: Default: Options:
Any combination of ASCII characters can be defined as the noread message. <K714,status,message> NOREAD 0 to 128 ASCII characters.
Note: Noread Message will only be transmitted if Bar Code Output (page 12-5) is set to Match, Mismatch or Good Read. Noread Message can be set to any ASCII characters except NULL <> and , (comma).
12-4
MS-880 Industrial Long Range Scanner User’s Manual
Page 183
Chapter 12 Outputs
Bar Code Output Note: Bar Code Output relates to data and should not to be confused with Outputs 1, 2, and 3 listed in the Outputs Parameters which describe output states and functions.
Bar Code Output Status Definition: Usage: Serial Cmd: Default: Options:
Defines the conditions under which decoded bar code labels are transmitted to the host. Useful when the host needs bar code data only under certain conditions. <K705,output status,when to output> Good Read 0 = Disabled 1 = Match 2 = Mismatch 3 = Good Read
Disabled Definition: Usage:
When set to Disabled, the scanner will not transmit any data that is generated during a read cycle (bar codes, noreads, etc.). It is useful when an application only needs to use the discrete outputs and can allow the scanner to do the decision-making. When Disabled, the host does not need the bar code data and the communication lines are used only for setup and status checks.
Match Definition:
Usage:
When set to Match, the scanner transmits bar code data whenever a bar code matches a master label. However, if Matchcode Type is Disabled, it transmits on any good read. Note: A noread can still be transmitted if Enabled. Match is used in an application that requires specific bar code information and needs to sort, route or verify based on matching the specific bar code data.
MS-880 Industrial Long Range Scanner User’s Manual
12-5
12–Outputs
Note: Bar Code Output Status if set to Match or Mismatch will not take effect unless Matchcode Type is enabled and a master label is loaded into memory.
Page 184
Bar Code Output Mismatch Definition:
Usage:
With Mismatch enabled, the scanner transmits bar code data whenever the bar code data information does NOT match the master label. Note: A noread can still be transmitted if enabled. Mismatch is typically used as a flag within the host system to prevent an item from being routed in the wrong container.
Good Read Definition:
Usage:
With Good Read enabled, the scanner transmits bar code data on any good read regardless of Matchcode Type setting. Note: A noread can still be transmitted if enabled. Good Read is used when an application requires all bar code data to be transmitted. It’s typically used in tracking applications in which each object is uniquely identified.
12–Outputs
When to Output Bar Code Data Definition: Serial Cmd: Default: Options:
This command allows the user to choose when bar code data can be sent to the host. <K705,output status,when to output> As Soon As Possible 0 = As Soon As Possible 1 = End of Read Cycle
As Soon As Possible Definition:
Usage:
12-6
Enabling As Soon As Possible causes bar code data to be sent to the host immediately after a bar code has been successfully decoded. Note: More than one decode might in fact be required to qualify as a good decode, depending on how Decodes Before Output is set. As Soon As Possible is useful in applications in which bar code data needs to be moved quickly to the host, typically when the host is making decisions based on bar code data.
MS-880 Industrial Long Range Scanner User’s Manual
Page 185
Chapter 12 Outputs End of Read Cycle Definition:
Enabling End of Read Cycle means that bar code data does not get sent to the host until the read cycle ends with a timeout or new trigger. End of read cycle
Start of read cycle Read cycle Duration Host activates trigger
This is when host expects output
Figure 12-1 Read Cycle Usage:
End of Read Cycle is useful in timing-based systems in which the host is not ready to accept data at the time it is decoded. Note: Whenever Quality Output is Enabled, outputs will always function in End Of Read Cycle mode.
12–Outputs
MS-880 Industrial Long Range Scanner User’s Manual
12-7
Page 186
Serial Verification
Serial Verification Allows the user to verify configuration command status.
Serial Command Echo Status Definition: Function:
12–Outputs
Usage:
Serial Cmd: Default: Options:
When enabled, a configuration command received from the host is echoed back to the host with the resultant settings. If a command with multiple fields is processed, some of the fields may have been processed properly while others were not. The changes will appear in the string echoed back so that the user will know which fields did or did not change. This command is useful in removing any doubt about the scanner’s interpretation of any configuration command. For example, if the current preamble is “SOM” and <Kd1, START> is entered, the scanner will echo back <Kd1, SOM> since the attempted entry “START” exceeds the four character limit for that command. Therefore it is rejected and the existing “SOM” message is echoed back and remains the preamble message. <K701,serial command echo status,serial command beep status,control/hex output> Disabled 0 = Disabled 1 = Enabled
Serial Command Beep Status Definition: Function:
Usage: Serial Cmd: Default: Options:
12-8
Causes the scanner to beep once whenever a K command is entered to indicate that the command was accepted and processed. If an invalid command is entered, the scanner beeps 5 times to indicate an invalid entry. However, this does not necessarily mean that all data fields have been entered incorrectly. Only one bad field needs to be found in order to activate the 5 beep response. Used to audibly verify the acceptance and validity of a command. <K701,serial command echo status,serial command beep status,control/hex output> Disabled 0 = Disabled 1 = Enabled
MS-880 Industrial Long Range Scanner User’s Manual
Page 187
Chapter 12 Outputs
Control/Hex Output Definition:
Usage: Serial Cmd: Default: Options:
Determines the response to an Serial Command Echo or status request command. When set to Control, two characters are transmitted to represent a non-displayable character. For example, a carriage return will be shown as the two characters: ^M. When set to Hex, the output is the hex character. Useful for viewing settings with binary characters when using serial command on a terminal. <K701,serial command echo status,serial command beep status,control/hex output> Control 0 = Control 1 = Hex
12–Outputs
MS-880 Industrial Long Range Scanner User’s Manual
12-9
Page 188
Beeper Status
Beeper Status Definition:
A beep is emitted either after each good read of a bar code label or after each noread. Note: Beeper will also sound if any of the following occur: • the scanner is defaulted • a send/save command from ESP or an Exit command from any embedded menu
Usage:
• a <Z>, <Zp>, <Zd>, or <K701,,1> command is sent Can be used as an audible verification that either a good read or a noread has occurred.
Status
12–Outputs
Serial Cmd: Default: Options:
<K702,status,volume> On Good 0 = Disabled 1 = On Good 2 = On Noread
Volume Serial Cmd: Default: Options:
12-10
<K702,status,volume> Level 4 0 = Off 1 = Level 1 2 = Level 2 3 = Level 3 4 = Level 4 5 = Level 5
MS-880 Industrial Long Range Scanner User’s Manual
Page 189
Chapter 12 Outputs
Quality Output Definition:
Usage:
Allows the host to track the number of good reads per trigger by appending a five digit numeric field to the end of bar code label data. When enabled, bar code data is followed by a separator, followed by the five digits in the form of 00000. For example, a certain bar code that has been averaging 00100 reads per read cycle suddenly drops to 00012, this would be a good indication that a problem has arisen even though good reads are still occurring. Host system can monitor scanning performance (printing process, scanning environment changes, etc.) by setting thresholds in their processing or displaying the outputs for visual verification.
See “Reads per Trigger Threshold” on page 14-9.
Separator <K704,quality output separator,reads/trigger status>
, (comma) any ASCII character
12–Outputs
Serial Cmd: Default: Options:
Note: For all serial configuration commands, the following characters cannot be used: , < > NUL
Reads/Trigger Status Serial Cmd: Default: Options:
<K704,quality output separator,reads/trigger status>
Disabled 0 = Disabled 1 = Enabled
MS-880 Industrial Long Range Scanner User’s Manual
12-11
Page 190
12–Outputs
Quality Output
12-12
MS-880 Industrial Long Range Scanner User’s Manual