For the Microscan MS-880

Page 161

Chapter 10 Scanner Setup

Definition:

During the read cycle, the scanner counts the number of bar and space transitions defined in the Transition Counter Threshold. If the count matches or exceeds the threshold, the scanner will perform AGC routines.

Transition Counter Status Serial Cmd:

<K505,transition counter status,transition counter threshold>

Default:

Enabled

Options:

0 = Disabled

1 = Enabled

Transition Counter Threshold Definition:

Determines the number of bar/space transitions that must be read before a label is considered present and AGC can be resolved.

Usage:

Can be useful in certain application where extraneous objects in the field of view might require a higher threshold.

Serial Cmd:

<K505,transition counter status,transition counter threshold>

Default:

14

Options:

0 to 255

MS-880 Industrial Long Range Scanner User’s Manual

10-7

10–Scanner Setup

Transition Counter

Page 162

10–Scanner Setup

Maximum Element

Maximum Element Definition:

Maximum Element represents the maximum bar element width that’s allowed before a video reset occurs (default to white).

Usage:

Useful if having difficulty reading large element symbols like PDF417. Caution: Do not change this parameter unless instructed by a Microscan representative.

Serial Cmd:

<K502,maximum element>

Default:

1000 (30.5 µs)

Options:

1 to 65535

10-8

MS-880 Industrial Long Range Scanner User’s Manual

Page 163

Chapter

Matchcode

11 11–Matchcode

Chapter Contents Overview of Matchcode .............................................................................11-4 Matchcode Type ........................................................................................11-5 Master Label Database ...........................................................................11-11 New Master Pin .......................................................................................11-16

This section explains the matchcode output functions and the master label database setup. Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.

MS-880 Industrial Long Range Scanner User’s Manual

11-1

Page 164

Matchcode by ESP

11–Matchcode

Click this button to bring up the Matchcode menu.

To change a setting, double-click the setting and use your curser to scroll through the options.

Matchcode by Serial Command Command Title old cmds

Matchcode Type

Kn

Master Label Database Size New Master Pin Sequential Step Enter/Delete Master Label Data

KM Kz

Request Master Label Data

M

Operations Status Request

KV?

11-2

M new cmds

Format

<K223,type,sequential matching,match start K223, position,match length,wild card character, sequence on noread,sequence on mismatch> K224, <K224,number of master labels> K225, <K225,status> K228, <K228,sequence step> <K231,master label number,master label data K231, [no data will delete]> <K231,?>[for all] or K231, <K231,master label number?> K399? <K399?>

MS-880 Industrial Long Range Scanner User’s Manual

Page 165

Chapter 11 Matchcode

Matchcode by Embedded Menu For information on accessing the embedded menus, see “Embedded Menus” on page A-23. From the Main menu, scroll down through the options and select the following screen:

11–Matchcode

MS-880 Industrial Long Range Scanner User’s Manual

11-3

Page 166

Overview of Matchcode

11–Matchcode

Overview of Matchcode Definition:

With Matchcode you can store master label data in the scanner’s memory, compare this data against the scanned bar codes, and define how label data and/or discrete signal output will be directed. A master label database can be setup for up to 10 master labels. See “Master Label Database” on page 11-11. Note: Matchcode will function with multiple labels (see “Multilabel” on page 4-16); however if Matchcode Type is set to Sequential or if Triggering Mode is set to Continuous Read 1 Output, Number of Labels will default back to 1 (if set to any number greater than 1).

Usage:

Matchcode is used in applications to sort, route, or verify data based on matching the specific bar code label in a variety of ways as defined in this section. For example, a manufacturer might sort a product based on dates that are embedded in the bar code.

Steps for entering and using master labels 1. Set Triggering Mode to External or Serial (“Trigger Mode” on page 4-4). 2. Chose the method of label comparison that fits your application (“Matchcode Type” on page 11-5). 3. Define the output you want to achieve with your matchcode setup: a. Barcode output (“Bar Code Output” on page 12-5). b. Discrete output (“Output 1” on page 14-5, “Output 2” on page 14-10, and “Output 3” on page 14-10). 3. Select the number of master labels you want to create (“Master Label Database Size” on page 11-11). 4. Decide which of 4 ways you want enter your master label(s): a. Use ESP to type in master label data directly (“Enter Master Label Data” on page 11-12). b. Send a serial command with label data in the form of <Mmaster label#,data>. c. Send a <G> (Scan Next Label as Master Label) command. d. Enable the New Master Pin command (“New Master Pin” on page 11-16) and activate a discrete input to store the in the next label scanned as master label. 5. Enter master label data using the method determined in step 4.

11-4

MS-880 Industrial Long Range Scanner User’s Manual

Page 167

Chapter 11 Matchcode

Matchcode Type Definition:

Allows the user to choose the way that master labels will be compared with subsequently scanned labels. Note: First set Triggering Mode to External or Serial.

ESP:

11–Matchcode

Serial Cmd:

<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on noread,sequence on mismatch>

Default:

Disabled

Options:

0 = Disabled 1 = Enabled 2 = Sequential 3 = Wild Card

Disabled:

Has no effect on operations.

Enabled:

Instructs the scanner to compare labels or portions of labels with the master label.

Wild Card:

Allows the user to enter user defined wild card characters in the master label.

Sequential Matching:

Instructs the scanner to sequence after each match (numeric only) and compare labels or portions of labels for sequential numbers. Note: If Matchcode Type is set to Sequential, Number of Labels will default back to 1 (if set to any number greater than 1).

MS-880 Industrial Long Range Scanner User’s Manual

11-5

Page 168

Matchcode Type

11–Matchcode

Sequential Matching Definition:

With Sequential enabled, Sequential Matching determines if a count is in ascending (incremental) or descending (decremental) order.

Usage:

Useful in tracking product serial numbers that increment or decrement sequentially.

Serial Cmd:

<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on noread,sequence on mismatch>

Default:

Increment

Options:

0 = Increment 1 = Decrement

Match Start Position Definition:

Match Start Position determines the portions of labels that will be matched by defining the first character in the label (from left to right) that will be compared with those of the master label, when Matchcode Type is set to Enabled or Sequential.

Function:

For example, if Match Start Position is set to 3, the first 2 characters read in the symbol will be ignored and only the 3rd and subsequent characters to the right will be compared, up to the number of characters specified by Match Length.

Usage:

Match Start Position is useful in defining specific portions of a symbol for comparisons. For example, if a symbol contains a part number, manufacturing date, and lot code info but the user is only interested in the part number information. With Match Start Position the scanner can be set to only sort on the part number and ignore the rest of the characters.

Serial Cmd:

<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on noread,sequence on mismatch>

Default:

0

Options:

0 to 2710

Note: Match Start Position must be set to 1 or greater to enable this feature. A 0 setting will disable this feature.

11-6

MS-880 Industrial Long Range Scanner User’s Manual

Page 169

Chapter 11 Matchcode

Match Length Defines the length of the character string that will be compared with that of the master label when Match Start Position is set to 1 or greater. when Match Start Position is set to 0, no comparison will occur.

Usage:

For example, if Match Length is set to 6 in a 10 character symbol, and Match Start Position is set for 2, only the 2nd through 7th characters (from left to right) will be compared.

Serial Cmd:

<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on noread,sequence on mismatch>

Default:

1

Options:

1 to 27102710

Wild Card Character Definition:

Wild Card Character allows a user to define a wild card character as part of the master label.

Usage:

For example, with Wild Card Character defined as the default asterisk, defining CR*34 as the master label will result in matches for CR134, CR234, but not CR2345. Entering the wild card at the end of the master label as in CR* will result in matches for variable label lengths such as CR1, CR23, CR358, etc.

Serial Cmd:

<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on noread,sequence on mismatch>

Default:

* (asterisk)

Options:

Any valid ASCII character

MS-880 Industrial Long Range Scanner User’s Manual

11-7

11–Matchcode

Definition:

Page 170

Matchcode Type

11–Matchcode

Sequence On Noread Definition:

When Sequence On Noread is Enabled and Matchcode is set to Sequential, the scanner sequences the master label on every match or noread. When disabled, it does not sequence on a noread.

Usage:

Sequence On Noread is useful when the scanner needs to stay in sequence even if no decode occurs.

Serial Cmd:

<K223,matchcode type,sequential matching,match start position, match length,wild card character,sequence on noread,sequence on mismatch>

Default:

Enabled

Options:

0 = Disabled

1 = Enabled

As an example of Sequence on Noread Enabled, consider the following series of decodes: Master label

Decoded label

Master label after decode

001 002 003 004 005 006 007

001 002 noread 004 noread noread 007

002 003 004 (sequenced on noread) 005 006 (sequenced on noread) 007 (sequenced on noread) 008

As an example of Sequence on Noread Disabled, consider the following series of decodes: Master label

Decoded label

Master label after decode

001 002 003 003 004 004 004

001 002 noread 003 noread noread 004

002 003 003 (not sequenced) 004 004 (not sequenced) 004 (not sequenced) 005

11-8