Page 141

Chapter 8 Optoelectrics

Control Trigger #1 Definition:

When Control Trigger mode is enabled, Control Trigger #1 “hijacks” Input 1 (see “Discrete I/0” in chapter 14) and uses it to select an optoelectric configuration from the configuration database. Active state is set by Input 1 serial command.

Serial Cmd:

<K226,mode,# active database settings,latch on trigger,timer value, control trigger 1,control trigger 2,control trigger 3>

Default:

Disabled

Options:

0 = Disabled 1 = Enabled

Control Trigger #2 New Master Pin is used for Control Trigger #2. When enabled and Mode is set to Control Trigger, this input is used to select a Optoelectric configuration from Configuration Database. Active State is “Active Closed”.

Serial Cmd:

<K226,mode,# active database settings,latch on trigger,timer value, control trigger 1,control trigger 2,control trigger 3>

Default:

Disabled

Options:

0 = Disabled 1 = Enabled

Control Trigger #3 Definition:

Trigger is used for Control Trigger #3, and when enabled and mode is set to Control Trigger, this input is used to select a Optoelectric configuration from the Configuration Database. The active state is set by the External Trigger State serial command.

Serial Cmd:

<K226,mode,# active database settings,latch on trigger,timer value, control trigger 1,control trigger 2,control trigger 3>

Default:

Disabled

Options:

0 = Disabled 1 = Enabled

MS-880 Industrial Long Range Scanner User’s Manual

8-9

8–Optoelectrics

Definition:

Page 142

Optoelectric Database Modes

Number of Active Database Settings Definition:

This value sets the number of configuration database settings (in Database Index) that are active. If Control Trigger mode has been selected, this setting is ignored.

Usage:

Can be useful when certain settings that are needed in one application are not needed in another and processing time is at a premium.

Serial Cmd:

<K226,mode,# active database settings,latch on trigger,timer value, control trigger 1,control trigger 2,control trigger 3>

Default:

1

Options:

Any number from 1 to 7.

8–Optoelectrics

ESP

Latch on Trigger Definition:

This feature is only used in Control Trigger mode. If enabled, the configuration database settings selected at the start of a read cycle will remain active during the entire read cycle. If Latch on Trigger is disabled, depending on the control trigger inputs, the scanner’s optical settings can change throughout the read cycle. Note: When Control Trigger #3 is enabled, Latch on Trigger is also enabled regardless of its previous setting.

Usage:

Useful when only one database index is required for the application.

Serial Cmd:

<K226,mode,# active database settings,latch on trigger,timer value, control trigger 1,control trigger 2,control trigger 3>

Default:

Enabled

Options:

0 = Disabled 1 = Enabled

ESP

8-10

MS-880 Industrial Long Range Scanner User’s Manual

Page 143

Chapter 8 Optoelectrics

Timer Value Definition:

When Timer mode is enabled, Timer Value is the time interval in which database index settings are cycled.

Usage:

Useful in slower applications where there is enough time to cycle through the database index.

ESP:

Serial Cmd:

<K226,mode,# active database settings,latch on trigger,timer value, control trigger 1,control trigger 2,control trigger 3>

Default:

5

Options:

0 to 255 (increments of 10ms)

8–Optoelectrics

MS-880 Industrial Long Range Scanner User’s Manual

8-11

Page 144

8–Optoelectrics

Optoelectric Database Modes

8-12

MS-880 Industrial Long Range Scanner User’s Manual

Page 145

Raster/Laser Control

Chapter

9

Chapter Contents Raster Setup ............................................................................................... 9-3 Laser Setup................................................................................................. 9-6 Raster/Laser by Embedded Menu .............................................................. 9-9

This section explains the setup and adjustments for the raster and the laser setups.

Raster/Laser Setup by Serial Command old cmds new cmds

Raster

KR

K506,

Laser

KC

K700,

Scanner Setup Status Request

KU?

K699? <K699?>

Command Title

Format <K506,status,top offset,bottom offset,raster sweep rate,read cycle on/off> <K700,laser on/off status,laser framing status,laser off time,laser on time,laser power>

MS-880 Industrial Long Range Scanner User’s Manual

9-1

9–Raster/Laser Con-

Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.

Page 146

Raster/Laser Setup by ESP Menus

Click on this button to bring up the Raster/Laser menu.

To change a setting, double-click on the setting and use your curser to scroll through the options.

Note: Setup commands in the ESP-MP are accessed from both the Read Cycle/Triggering menu and the Raster button on the toolbar.

Raster/Laser Setup by Embedded Menu

9–Raster/Laser Con-

To access the Raster/Laser menu from within the Autocalibration Setup menu (page 6-8), type the number 2.

9-2

MS-880 Industrial Long Range Scanner User’s Manual

Page 147

Chapter 9 Raster/Laser Control

Raster Setup Definition:

The user can enable raster scanning and adjust the sweep range (the upper and lower limits of the raster sweep).

Usage:

Raster scanning is useful when labels vary in placement and a single scan line cannot be counted on to cross the label. Raster scanning is also useful in reading PDF417.

Serial Cmd:

<K506,status,top offset,bottom offset,raster sweep rate,read cycle on/off>

Raster Status Definition:

When disabled, the raster mirror will park at the top of the raster sweep.

Serial Cmd:

<K506,status,top offset,bottom offset,raster sweep rate,read cycle on/off>

Default:

Disabled

Options:

0 = Disabled 1 = Enabled

Note: Raster sweeps are only counted during a read cycle (continuous, triggered, and read rate). Raster sweeps are NOT counted when the raster motor is parked, disabled, set to straight line operation (top and bottom are equal), or when performing a selfcalibration.

Top Offset Decreasing the Top Offset value causes the top of the raster pattern to move up.

Serial Cmd:

<K506,status,top offset,bottom offset,raster sweep rate,read cycle on/off>

Default:

127

Options:

0 to 255

MS-880 Industrial Long Range Scanner User’s Manual

9–Raster/Laser Con-

Definition:

9-3

Page 148

Raster Setup

Bottom Offset Definition:

Increasing the Bottom Offset value causes the bottom of the raster pattern to move down.

Serial Cmd:

<K506,status,top offset,bottom offset,raster sweep rate,read cycle on/off>

Default:

127

Options:

0 to 255

9–Raster/Laser Con-

Note: For single scan line operation, set Top Offset equal to Bottom Offset or click on the Static Line option. Note: Assigning a larger value to Top Offset than Bottom Offset will park the raster mirror in its “home” (default) position.

9-4

MS-880 Industrial Long Range Scanner User’s Manual

Page 149

Chapter 9 Raster/Laser Control

Raster Sweep Rate Definition:

The raster sweep rate is the number of sweeps per second the raster mirror completes. A sweep is one pass of the raster, up or down. The maximum sweep rate is limited by the size of the arc the raster must move through.

Usage:

If your application allows it, a slower sweep rate can produce more scans per second and better read rates. To determine the minimum read rate for your application, see “Raster Picket Fence Calculation” on page A-32.

Serial Cmd:

<K506,status,top offset,bottom offset,raster sweep rate,read cycle on/off>

Default:

10

Options:

0 to 30

Table 9-1 Maximum Sweep Rates at Selected Sweep Arcs Raster Sweep Arc 0 to 10° 11 to 20° 21 to 30°

Maximum Sweeps per Second 30 20 10

9–Raster/Laser Con-

MS-880 Industrial Long Range Scanner User’s Manual

9-5

Page 150

Laser Setup

Laser Setup The laser can be turned off between read cycles and the duration of the scan and hence the width of the scan can also be adjusted.

Laser On/Off Status Definition: Usage:

Serial Cmd: Default: Options:

When enabled, the laser is ON only during the read cycle. When disabled, the laser operates continuously. Laser On/Off extends the life of the laser. It is useful where there are significant time gaps between symbols. It also provides visual confirmation of a read cycle duration and minimizes laser exposure to people. <K700,laser on/off status,laser framing status,laser off time,laser on time,laser power> Disabled 0 = Disabled 1 = Enabled

Note: A serial or external trigger must be enabled for Laser On/Off to take effect.

9–Raster/Laser Con-

Note: Laser On/Off is not recommended when New Trigger is enabled, since the laser will effectively remain on continuously.

9-6

MS-880 Industrial Long Range Scanner User’s Manual