Page 131
Chapter 7 Calibration Database
Save Current Settings to Configuration Database Definition:
Saves current settings to the configuration database index.
Serial Cmd:
<K227+, database index>
Options:
1 to 7
Load Current Settings from Configuration Database Loads a specific database index.
Serial Cmd:
<K227-, database index>
Options:
1 to 7
7–Calibration Data-
Definition:
Request Database Settings Definition:
Associates a specific tracking setting with a database index.
Serial Cmd:
<K227?,database index>
Options:
1 to 7
Returns settings for selected Configuration Database Index. Sending <K227?,1> will return the record for the first database index, for example:
Sending <K227?> Returns settings for the entire Configuration Database in the following format:
The configuration database allows the user to save multiple scanner configuration settings. The database can be used simply to save most commonly used scanner configurations to allow scanner to be easily adaptable to changing applications, or used in conjunction with the Optoelectric Control, to dynamically change configurations.
MS-880 Industrial Long Range Scanner User’s Manual
7-5
Page 132
Calibration Database by Embedded Menu
Calibration Database by Embedded Menu
7–Calibration Data-
To access the Configuration Database menu from within the Autocalibration Setup menu (page 6-8), type the number 3.
You can save your calibration settings in up to 7 database indexes. 1. Type D to save your present settings to the configuration database. Note: From within the Autocalibration Setup menu, type the letter C. The current Gain, Tracking, and Focus settings will be saved in Index 1. Caution: Subsequent saves will overwrite your original settings unless you change the # Active Settings to a number at least one greater than the number of index settings currently filled. 2. Change the # Active Settings to the number of index settings you expect to fill. 3. Press CR to return to the Autocalibration Setup menu and calculate the next label position (if applicable). 4. Type D to save to the next index of autocalibration settings. The database index will automatically increment by 1 and place your settings in the next available index. Note: See “Focus Position” on page 10-5 for additional ways for saving and recalling database indexes. 5. Press the enter key (CR) to return to the main calibration menu or Esc to leave the Autocalibration Setup menu entirely.
7-6
MS-880 Industrial Long Range Scanner User’s Manual
Page 133
Chapter
Optoelectrics
8 Chapter Contents
This section tells how to apply optical settings such as Focus, Gain, and Tracking that you learned how to acquire in Chapter 6, “Autocalibration” and how to store in Chapter 7, “Calibration Database.” Note: The characters NULL <> and , can only be entered through embedded menus, not through ESP or serial commands.
MS-880 Industrial Long Range Scanner User’s Manual
8-1
8–Optoelectrics
Overview of Optoelectrics............................................................................8-4 Optoelectric Database Modes .....................................................................8-5
Page 134
Optoelectric by ESP
8–Optoelectrics
Click on this button to bring up the Optoelectric Control menu.
To change a setting, double-click on the setting and use your curser to scroll through the options.
Optoelectrics by Serial Command Command Title old comds
Optoelectric Control Scanner Setup Status Request
8-2
KU?
new cmds
Format
K226,
<K226,mode,# active database settings,latch on trigger,timer value, control trigger 1,control trigger 2,control trigger 3>
K699?
<K699?>
MS-880 Industrial Long Range Scanner User’s Manual
Page 135
Chapter 8 Optoelectrics
Optoelectrics by Embedded Menu For information on accessing the embedded menus, see “Embedded Menus” on page 23. To access the Configuration Database menu from within the Autocalibration Setup menu (page 6-8), type the number 3.
8–Optoelectrics
MS-880 Industrial Long Range Scanner User’s Manual
8-3
Page 136
Overview of Optoelectrics
Overview of Optoelectrics Definition:
A database index of up to seven pre-defined optical indexes of settings defining focus, gain, and tracking can be accessed and applied in the following modes: 1. by timer in which all indexes are attempted over a predefined timeout period. 2. by an automatic search for the best database index. 3. by a combination of up to three control trigger inputs to dynamically select the optimum database index. The index settings can also be saved and recalled selectively, or reviewed with a Request Database Settings command. Useful where different symbol types, sizes, qualities or distances require more that one optical setup (focus, gain, and tracking) for dynamic optical changes.
8–Optoelectrics
Usage:
8-4
MS-880 Industrial Long Range Scanner User’s Manual
Page 137
Chapter 8 Optoelectrics
Optoelectric Database Modes Definition:
A database index of up to seven pre-defined optical indexes of settings defining focus, gain, and tracking can be accessed and applied in the following modes: 1. by a timer in which all settings cycle throughout the time duration 2. by an automatic search for the best database index 3. by a combination of up to three control trigger inputs to dynamically select the optimum database index The index settings can also be saved and recalled selectively, or reviewed with a Request Database Settings command.
Usage:
Useful where different symbol types, sizes, qualities or distances require more that one optical setup (focus, gain, and tracking) for dynamic optical changes.
Serial Cmd:
<K226,mode,# active database settings,latch on trigger,timer value, control trigger 1,control trigger 2,control trigger 3>
Default:
Disabled
Options:
0 = Disabled 1 = Control Trigger 2 = Automatic/static mode 3 = Timer
8–Optoelectrics
ESP:
Disabled Mode Definition:
When disabled, the scanner uses the current scanner configuration settings.
Serial Cmd:
<K226,mode,# active database settings,latch on trigger,timer value, control trigger 1,control trigger 2,control trigger 3>
MS-880 Industrial Long Range Scanner User’s Manual
8-5
Page 138
Optoelectric Database Modes
Timer Mode Definition:
When this mode is selected, the scanner cycles through database settings at a time interval determined in Timer Value setting. (See “Timer Value” on page 8-11.) Important Note: The maximum time to move from the most inside focus position to the most outside focus position is 400 ms. One focus position change takes 10 ms.
Usage:
Useful in applications in which there is enough time to cycle through the database index.
Serial Cmd:
<K226,mode,# active database settings,latch on trigger,timer value, control trigger 1,control trigger 2,control trigger 3>
8–Optoelectrics
Calibration with Multilabel With Multilabel enabled for more than one label, and either Timer or Automatic/ Static mode enabled, the scanner may not locate labels that are scanned at various ranges. The reason for this is that once a label is located from the optical database index, the scanner will continue to search for labels that meet that index of focus, tracking and gain settings.
Automatic/Static Mode Definition:
Selects the optimum setting from the Configuration Database. When selected, the scanner cycles once through all the Configuration Database settings from the closest to the furthermost focal position, testing first for optimal signal, then for a successful decode. Note: Since focus positions are tested in ascending order, the closer the symbols are to the scanner, the quicker the best focus position will be found. Important Note: The maximum time to move from the most inside focus position to the most outside focus position is 400 ms. One focus position change takes 10 ms.
Usage:
Useful in a static application in which the bar code symbol is in front of the scanner when the read cycle begins.
ESP:
Serial Cmd:
8-6
<K226,mode,# active database settings,latch on trigger,timer value, control trigger 1,control trigger 2,control trigger 3>
MS-880 Industrial Long Range Scanner User’s Manual
Page 139
Chapter 8 Optoelectrics
Control Trigger Mode Definition:
When Optoelectric Control mode is set to Control Trigger, input 1, new master pin, and the trigger input pins are de-activated and reassigned as control triggers. When activated, a read cycle will be triggered and - in accordance with their respective states - select from a database of up to seven pre-defined optical settings of Focus, Gain, and Tracking. (See Chapter 7, “Calibration Database.”)
Usage:
Useful where different symbol types, sizes, and/or distances benefit from pre-defined optical setups (focus, gain, and tracking) that can be accessed ‘on the fly’ according to the combination of input states.
Serial Cmd:
<K226,mode,# active database settings,latch on trigger,timer value, control trigger 1,control trigger 2,control trigger 3>
8–Optoelectrics
MS-880 Industrial Long Range Scanner User’s Manual
8-7
Page 140
Optoelectric Database Modes Process:
To use Control Trigger: 1. Setup your application’s labels by code type/size in the various positions and/or code type/size at which they will likely appear. 2. Sketch out a diagram as in figure 8-1. 3. Setup your sensors or other controls. For example, the three object sensors, 1, 2 & 3, are connected to input 1, new master pin, and trigger input respectively. The bar coded packages on the left are numbered here according to their database index numbers. Package #7 will cross all three of the sensors and thus activate the settings for index #7 as shown.
1
1
3
7
5
8–Optoelectrics
In this scenario only four index settings are possible. However, up to seven combinations are possible with other input devices such as PLCs. 3 2 You can also enable/disable any Figure 8-1 Control Trigger combination controls by clicking on Inputs the Control Trigger Status buttons on the bottom of the Control Trigger Map. The red buttons indicate active states on the three control triggers. The combination of active/inactive triggers determines the focus, gain, and tracking settings that will be applied during a read cycle. For example, if only Control Trigger 1 is active, the focus, gain, and tracking values that appear in the top row will be applied.
Figure 8-2 ESP Control Trigger Setup
8-8